Thermal Circuit Breaker Circuit Breaker 142

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

CCB25

Littelfuse

Thermal Circuit Breaker

Panel Mount

12 V

25 A

Quick Connect

Automatic Reset

SAE

W33-T2N1Q-20

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W33-T4B1Q-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W33-T4B1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

3120-F321-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

20 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F323-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F324-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

100 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

3120-F324-P7T1-W01D-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

6 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

1410-L210-L2F1-S02-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

2 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1410-L210-L2F1-S02-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

5 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

5SY4102-7

Siemens

Thermal Circuit Breaker

Panel Mount

400 V

2 A

Screw

-25 °C (-13 °F)

10 kA

5SY

Sealed Bat

3.543 in (90 mm)

0.709 in (18 mm)

IP20

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Under Voltage Release

2.756 in (70 mm)

CCC; CUL; EN; GOST; IMQ; UL; VDE

1

45 °C (113 °F)

Standard

6-1393250-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

W28-XT1A-3

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

W58-XC4C12A-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Lug

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

W33-S1N1Q-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W33-S1N1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

1110-F112-P1M1-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

2 A

Quick Connect

-20 °C (-4 °F)

1 kA

ENVIRONMENTAL CHARACTERISTICS: IP40; IP00

Push Button

0.748 in (19 mm)

0.52 in (13.2 mm)

Corrosion Resistant; Moisture Resistant

0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm)

Tease-Free And Trip-Free

1.87 in (47.5 mm)

CBE; CSA; IEC; UL; VDE

1

60 °C (140 °F)

Medium

W23-X1A1G-50

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W23-X1A1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-15

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-25

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

25 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

1410-L110-L1F1-S01-1A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

1 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00

Reset Button

0.984 in (25 mm)

0.504 in (12.8 mm)

Corrosion Resistant; Moisture Resistant

e4

0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm)

0.591 in (15 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1180-01-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

72 V

6 A

Quick Connect

-20 °C (-4 °F)

2 kA

Push Button

1.921 in (48.8 mm)

0.323 in (8.2 mm)

IP00; IP40

0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm)

Trip Free

0.961 in (24.4 mm)

CQC; CSA; EN; IEC; UL; VDE

1

60 °C (140 °F)

CMB-033-27J6N-B-D/03

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

CMB-053-27G3N-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

5 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

CMB-153-11C3N-B-A/15

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

15 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

CMB-153-11C3N-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

15 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

CMB-203-27J8N-B-A/20

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

TS-709-5

Schurter Ag

Thermal Circuit Breaker

Panel Mount

125 V

32 V

5 A

Quick Connect

1 kA

Push To Reset

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Trip Free

0.886 in (22.5 mm)

UL

1

CLB-103-27E3N-W-A/10

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; CSA; TUV; UL

1

60 °C (140 °F)

1620-2-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

10 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

15 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

20 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-25A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

25 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

30 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

10 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

15 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

20 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

30 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1658-G21-01-P13-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

15 A

Quick Connect

-20 °C (-4 °F)

1 kA

Push To Reset

Bulk

1.26 in (32 mm)

0.535 in (13.6 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.063 in (27 mm)

CSA; CUL; UL

1

60 °C (140 °F)

3120-F323-P7T1-W19FG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Tab/Blade

-30 °C (-22 °F)

5 kA

Rocker

Bulk

2.126 in (54 mm)

0.984 in (25 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CSA; UL

2

60 °C (140 °F)

413-K14-FN2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-35A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

35 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.