| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
Panel Mount |
250 V |
65 V |
10 A |
Screw |
-30 °C (-22 °F) |
800 A |
Rated breaking capacity at 32 VDC: 2500 A |
Toggle |
1.772 in (45 mm) |
0.492 in (12.5 mm) |
1.772 x 0.492 x 0.122 in (45 x 12.5 x 3.09 mm) |
Manual On/Off |
0.122 in (3.09 mm) |
CSA; GL; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
80 V |
2 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
Handle |
Bulk |
3.516 in (89.3 mm) |
1.378 in (35 mm) |
IP20 |
Under Voltage Release |
2.693 in (68.4 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
80 V |
20 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
Handle |
Bulk |
3.516 in (89.3 mm) |
1.378 in (35 mm) |
IP20 |
Under Voltage Release |
2.693 in (68.4 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
|||||||||
|
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
80 V |
4 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
Handle |
Bulk |
3.516 in (89.3 mm) |
1.378 in (35 mm) |
IP20 |
Under Voltage Release |
2.693 in (68.4 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
6 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
Bulk |
4.146 in (105.3 mm) |
0.689 in (17.5 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
1 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
2 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
3.516 in (89.3 mm) |
2.067 in (52.5 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
3 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
6 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
1 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
Bulk |
3.516 in (89.3 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.693 in (68.4 mm) |
CE; CUL; UL |
3 |
55 °C (131 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
4 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
15 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
Bulk |
3.516 in (89.3 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.693 in (68.4 mm) |
CE; CUL; UL |
3 |
55 °C (131 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
8 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
2.067 in (52.5 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
3 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
2.067 in (52.5 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
3 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
1 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
Bulk |
3.516 in (89.3 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.693 in (68.4 mm) |
CE; CUL; UL |
3 |
55 °C (131 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
10 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
15 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
8 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
4 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
1 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle |
Bulk |
3.516 in (89.3 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.693 in (68.4 mm) |
CE; CUL; UL |
3 |
55 °C (131 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
240 V |
25 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
2.067 in (52.5 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
3 |
60 °C (140 °F) |
||||||||||
|
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
1 A |
Screw And Snap On |
-20 °C (-4 °F) |
100 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm) |
Trip |
3.091 in (78.5 mm) |
EN; IEC |
3 |
60 °C (140 °F) |
||||||||
|
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
10 A |
Screw And Snap On |
-20 °C (-4 °F) |
3 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm) |
Trip |
3.091 in (78.5 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
||||||||
|
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
1.6 A |
Screw And Snap On |
-20 °C (-4 °F) |
100 kA |
Push Button |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
Trip |
3.091 in (78.5 mm) |
EN; IEC |
3 |
60 °C (140 °F) |
|||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
125 V |
5 A |
Snap On |
-35 °C (-31 °F) |
5 kA |
Toggle Handle |
3.228 in (82 mm) |
1.39 in (35.3 mm) |
Corrosion Resistant; IP20 |
Trip Free |
2.37 in (60.2 mm) |
UL; TUV |
2 |
70 °C (158 °F) |
||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
15 A |
Snap On |
-35 °C (-31 °F) |
5 kA |
Toggle Handle |
3.228 in (82 mm) |
2.083 in (52.9 mm) |
Corrosion Resistant; IP20 |
Trip Free |
2.37 in (60.2 mm) |
UL; TUV |
3 |
70 °C (158 °F) |
|||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
1 A |
Snap On |
-35 °C (-31 °F) |
5 kA |
Toggle Handle |
3.228 in (82 mm) |
2.083 in (52.9 mm) |
Corrosion Resistant; IP20 |
Trip Free |
2.37 in (60.2 mm) |
UL; TUV |
3 |
70 °C (158 °F) |
|||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
59 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.512 in (140 mm) |
2.165 in (55 mm) |
IP00; IP20 |
5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm) |
Trip |
5.866 in (149 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
6.3 A |
Screw And Snap On |
-20 °C (-4 °F) |
4 kA |
Rotary Handle |
5.669 in (144 mm) |
1.772 in (45 mm) |
IP00; IP20 |
5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
32 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
36 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.512 in (140 mm) |
2.165 in (55 mm) |
IP00; IP20 |
5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm) |
Trip |
5.866 in (149 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
45 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.512 in (140 mm) |
2.165 in (55 mm) |
IP00; IP20 |
5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm) |
Trip |
5.866 in (149 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
16 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
20 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.669 in (144 mm) |
1.772 in (45 mm) |
IP00; IP20 |
5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
52 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.512 in (140 mm) |
2.165 in (55 mm) |
IP00; IP20 |
5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm) |
Trip |
5.866 in (149 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
8 A |
Screw And Snap On |
-20 °C (-4 °F) |
4 kA |
Rotary Handle |
5.669 in (144 mm) |
1.772 in (45 mm) |
IP00; IP20 |
5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
16 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
3.819 in (97 mm) |
2.559 in (65 mm) |
IP20 |
3.819 x 2.559 x 3.819 in (97 x 65 x 97 mm) |
Relay Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
1 A |
Screw And Snap On |
-20 °C (-4 °F) |
100 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
250 mA |
Screw And Snap On |
-20 °C (-4 °F) |
100 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
32 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
5 A |
Screw And Snap On |
-20 °C (-4 °F) |
4 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
20 A |
Screw And Snap On |
-20 °C (-4 °F) |
2 kA |
Rotary Handle |
5.669 in (144 mm) |
1.772 in (45 mm) |
IP00; IP20 |
5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
|
Legrand |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
25 A |
Snap On |
-25 °C (-13 °F) |
50 kA |
Toggle Handle |
Bulk |
4.106 in (104.3 mm) |
2.102 in (53.4 mm) |
Manual On/Off |
3.11 in (79 mm) |
IEC |
2 |
70 °C (158 °F) |
||||||||||
|
|
Legrand |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
25 A |
Snap On |
-25 °C (-13 °F) |
50 kA |
Toggle Handle |
Bulk |
4.106 in (104.3 mm) |
3.154 in (80.1 mm) |
Manual On/Off |
3.11 in (79 mm) |
IEC |
3 |
70 °C (158 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.