277 V Circuit Breaker 80

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

BB3-B0-26-620-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

1.5 kA

Toggle Handle

2 in (50.8 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

CJ3-B2-26-625-524-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

2.16 in (54.86 mm)

CSA; UL

3

85 °C (185 °F)

W68-X2Q10-10

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

30 ms

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Series Trip

1.64 in (41.66 mm)

2

85 °C (185 °F)

W91-X113-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Stud

-40 °C (-40 °F)

5 kA

150 ms

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W92-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

W92-X112-25

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

2.5 x 1.5 x 2.001 in (63.5 x 38.1 x 50.82 mm)

Series Trip

2.001 in (50.82 mm)

2

85 °C (185 °F)

W92-X112-3

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

W93-X112-15

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

W93-X112-40

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

40 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

W91-X112-20

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W91-X112-2

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

2 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

2907640

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

20 A

Snap On

-35 °C (-31 °F)

10 kA

Bulk

4.567 in (116 mm)

0.693 in (17.6 mm)

2.665 in (67.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

102082

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

4 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

102083

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

102164

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

102167

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

10 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

DA3-B0-20-615-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

15 A

Screw

-40 °C (-40 °F)

5 kA

Toggle Handle

3.612 in (91.75 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.165 in (54.99 mm)

CSA; UL

3

85 °C (185 °F)

1020036

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

63 A

Snap On

-35 °C (-31 °F)

7.5 kA

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

3

70 °C (158 °F)

5SY4103-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

5SY4102-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

2 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

5SY4110-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

1019995

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

2

70 °C (158 °F)

1019973

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

1

70 °C (158 °F)

1020002

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

10 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

2

70 °C (158 °F)

1019987

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

30 A

Snap On

-35 °C (-31 °F)

5 kA

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

1019986

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip Free

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

AA1-B0-26-625-3D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-625-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

1019977

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

6 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.37 in (60.2 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

1019974

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

3 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

2908219

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

6 A

Snap On

-35 °C (-31 °F)

Handle

Bulk

3.378 in (85.8 mm)

0.354 in (9 mm)

Trip

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

1019997

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

4 A

Screw

-35 °C (-31 °F)

5 kA

Handle

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

2

70 °C (158 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.