1 A Circuit Breaker 29

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3C1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3B1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3D1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

W58-XC4C12A-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Lug

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

GV2ME05

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

1410-L110-L1F1-S01-1A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

1 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00

Reset Button

0.984 in (25 mm)

0.504 in (12.8 mm)

Corrosion Resistant; Moisture Resistant

e4

0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm)

0.591 in (15 mm)

CSA; UL; VDE

1

70 °C (158 °F)

CA1-B0-32-410-311-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

1 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

MF1-B-32-410-1-CC6-2-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Illuminated Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

CSA; UL; VDE

1

85 °C (185 °F)

MG1-B-32-410-1-CC1-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Illuminated Rocker

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

UL; CSA

1

85 °C (185 °F)

MT1-B-32-410-1-C21-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Push-Pull

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.484 in (37.69 mm)

UL; CSA

1

85 °C (185 °F)

MT1-B-32-410-1-C23-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Push-Pull

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.484 in (37.69 mm)

UL; CSA

1

85 °C (185 °F)

MU1-B-32-410-1-C21-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Push To Reset

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Chemical/Corrosion/Moisture Resistant

Series Trip

1.484 in (37.69 mm)

CSA; UL

1

85 °C (185 °F)

AA2-B0-26-410-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

1 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AC1-B0-32-410-313-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Screw

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AC1-B1-14-410-243-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

1 A

Screw

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AJ1-B0-32-410-1C3-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AK1-B0-32-410-1C3-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

4230-T130-K0CE-1A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

2.083 in (52.9 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

3

70 °C (158 °F)

3RV2011-0JA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

229-2-1-61-8-8-1-A

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

1 A

Stud

5 kA

Toggle Handle

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

2

MF1-B-32-410-1-CE3-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

360 A

Rated breaking capacity at 80 VDC: 600 A

Rocker

1.56 in (39.62 mm)

0.77 in (19.56 mm)

Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

CSA, UL

1

85 °C (185 °F)

3RV2011-0JA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

GV2ME053

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

5SY4301-7

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

1 A

Snap On

10 kA

3.535 in (89.8 mm)

2.079 in (52.8 mm)

IP20

3.535 x 2.079 x 2.992 in (89.8 x 52.8 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; KC; RCM; UL; VDE

3

5SY4201-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

1 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

R58-1A

Nte Electronics

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Quick Connect

1 kA

Rated breaking capacity at 50 VDC: 2000 A

Push Button

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Trip

1.375 in (34.93 mm)

CSA; UL

1

CA1-B0-14-410-321-MF

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

1 A

Stud

-40 °C (-40 °F)

Toggle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL; VDE

1

85 °C (185 °F)

J7MC-3P-1

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

1 A

Screw

-20 °C (-4 °F)

100 kA

Rocker

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Trip

2.941 in (74.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

J7MC-3R-1

Omron

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

1 A

Screw

-20 °C (-4 °F)

100 kA

Rotary Knob

5.118 in (130 mm)

1.772 in (45 mm)

IP20

Manual On/Off

3.728 in (94.7 mm)

CCC; CE; CUL; IEC; PSE; TUV; UL

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.