25 A Circuit Breaker 30

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

CCB25

Littelfuse

Thermal Circuit Breaker

Panel Mount

12 V

25 A

Quick Connect

Automatic Reset

SAE

2DU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3CU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

W31-X2M1G-25

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

25 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

CA1-B0-16-625-622-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

25 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-46-625-622-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

25 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

AA1-B0-14-625-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

25 A

Quick Connect

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA2-B0-10-625-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

25 A

Quick Connect

-40 °C (-40 °F)

7.5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AA2-B0-34-625-9G7-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AB2-B0-34-625-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AC2-B0-24-625-431-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

2

85 °C (185 °F)

AD2-B0-34-625-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

1620-2-25A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

25 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

BA1-B2-46-625-52A-K3

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

UL; TUV

1

85 °C (185 °F)

BA2-B0-46-625-521-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

2

85 °C (185 °F)

BA2-B2-36-625-525-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

2

85 °C (185 °F)

410202

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Manual On/Off

3.11 in (79 mm)

IEC

2

70 °C (158 °F)

410215

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

BB2-B0-26-625-522-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

2

85 °C (185 °F)

BB2-B2-26-625-522-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

3 kA

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

2

85 °C (185 °F)

CJ3-B2-26-625-524-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

2.16 in (54.86 mm)

CSA; UL

3

85 °C (185 °F)

CJ3-B2-26-625-524-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Rocker

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

2.16 in (54.86 mm)

CSA; UL; VDE

3

85 °C (185 °F)

PCG-BA-24-625-1GA-E11

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

25 A

Stud

-35 °C (-31 °F)

5 kA

Toggle Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

W67-X2Q52-25

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

25 A

Quick Connect

2.2 s

Toggle

Series Trip

1

W92-X112-25

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

2.5 x 1.5 x 2.001 in (63.5 x 38.1 x 50.82 mm)

Series Trip

2.001 in (50.82 mm)

2

85 °C (185 °F)

GV3P25

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

25 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

1019986

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

25 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip Free

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

AA1-B0-26-625-3D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-625-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

25 A

Screw

-40 °C (-40 °F)

5 kA

Toggle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

GV2P22

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

25 A

Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.819 in (97 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; IEC; LROS; RINA; UKCA; UL

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.