30 A Circuit Breaker 25

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

W68-X2Q12-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Quick Connect

2.5 kA

2.2 s

Toggle

Series Trip

2

MS1-B-14-630-3-1BB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

MS1-B-14-630-3-1CB-A-A

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

1

85 °C (185 °F)

MS1-B-14-630-3-1CB-A-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

50 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Standards: MIL-PRF-55629, MIL-STD-202

Toggle

1.375 in (34.93 mm)

0.656 in (16.66 mm)

IP68

Series Trip

1.634 in (41.5 mm)

CSA; CUL; UL

1

85 °C (185 °F)

W69-X2Q12-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Quick Connect

-40 °C (-40 °F)

2.5 kA

2.2 s

Toggle

2.25 in (57.15 mm)

2 in (50.8 mm)

Fungus Resistant; Moisture Resistant

2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

3

85 °C (185 °F)

Standard

W91-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W92-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Moisture Resistant

Series Trip

1.985 in (50.42 mm)

CSA; UL; VDE

2

85 °C (185 °F)

Standard

AA1-B0-34-630-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA2-B0-44-630-5B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

1620-2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

30 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

30 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

413-K14-FN2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-N2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

482-G111-K1M1-A1S0-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

72 V

30 A

Screw

-55 °C (-67 °F)

5 kA

Push-Pull

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.969 in (50 mm)

CSA; CUL; UL

1

75 °C (167 °F)

C21-B0-20-630-41A-E

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

30 A

Stud

-40 °C (-40 °F)

7.5 kA

Rocker

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; TUV; UL

1

85 °C (185 °F)

MS1-B-14-630-3-1CB-A-0AC

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

65 V

30 A

Screw

-40 °C (-40 °F)

3 kA

Sealed Toggle

1.375 in (34.93 mm)

0.65 in (16.51 mm)

Moisture Resistant; IP68;

Series Trip

2.158 in (54.81 mm)

CUL; UL

1

85 °C (185 °F)

219-3-1-66-8-2-30-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

30 A

Quick Connect

10 kA

Toggle Handle

5.8 in (147.32 mm)

3.108 in (78.94 mm)

Moisture Resistant

Trip Free

2.61 in (66.29 mm)

CSA; CUL; UL; VDE

3

PCG-BA-24-630-11A-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

30 A

Stud

-35 °C (-31 °F)

5 kA

Toggle Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

PCG-BA-24-630-1AA-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

30 A

Stud

-35 °C (-31 °F)

3 kA

Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Series Trip

2.975 in (75.57 mm)

CSA; UL

2

66 °C (150.8 °F)

W54-XA1C4A10-30

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

30 A

Lug

0 °C (32 °F)

1 kA

5 s

Push To Reset

1.378 in (35 mm)

0.575 in (14.6 mm)

Series Trip

1.22 in (31 mm)

1

60 °C (140 °F)

413-K14-LN2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

1019987

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

30 A

Snap On

-35 °C (-31 °F)

5 kA

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

CCP2R-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

600 V

125 V

30 A

Snap On

200 kA

Toggle Handle

3.7 in (93.98 mm)

0.3 in (7.62 mm)

1.9 in (48.26 mm)

UL

2

CCP2SL-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

DIN Rail Mount

600 V

125 V

30 A

Snap On

200 kA

Toggle Handle

3.7 in (93.98 mm)

0.3 in (7.62 mm)

Manual On/Off

1.9 in (48.26 mm)

2

CCP2-2-30CC

Eaton Corporation

Equipment Leakage Circuit Breaker

Panel Mount

600 V

125 V

30 A

200 kA

Toggle Handle

3.1 in (78.74 mm)

1.4 in (35.56 mm)

Manual On/Off

3.9 in (99.06 mm)

UL

2

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.