| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
80 V |
4 A |
Screw And Snap On |
-25 °C (-13 °F) |
10 kA |
Handle |
Bulk |
3.516 in (89.3 mm) |
1.378 in (35 mm) |
IP20 |
Under Voltage Release |
2.693 in (68.4 mm) |
CSA; UL; VDE |
2 |
55 °C (131 °F) |
||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
4 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
4 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
4 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
4 A |
Snap On |
-25 °C (-13 °F) |
5 kA |
5SY4104-7 |
Environmental Characteristics: IP20; Sealed |
3.535 in (89.8 mm) |
0.693 in (17.6 mm) |
Environment/Moisture Resistant |
3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm) |
Trip |
2.764 in (70.2 mm) |
CCC; CE; EAC; GOST; IMQ; KTL; UL; VDE |
1 |
55 °C (131 °F) |
||||||||
|
|
Schurter Ag |
Thermal Circuit Breaker |
Through Hole Mount |
240 V |
48 V |
4 A |
Solder |
-5 °C (23 °F) |
2 kA |
Reset Type |
Bulk |
0.748 in (19 mm) |
0.575 in (14.6 mm) |
IP40 |
Trip Free |
1.421 in (36.1 mm) |
CCC; CSA; GB; IEC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
125 V |
4 A |
Snap On |
-30 °C (-22 °F) |
6 kA |
Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40 |
Toggle |
2.874 in (73 mm) |
1.417 in (36 mm) |
Environment/Moisture Resistant; IP20 |
2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm) |
Trip |
4.213 in (107 mm) |
CCC; CSA; GB; IEC; UL |
2 |
70 °C (158 °F) |
|||||||
|
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
48 V |
4 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Rated breaking capacity at 400 VAC |
IP20; IP40 |
Trip |
CE; CSA; EN; IEC; UL |
1 |
75 °C (167 °F) |
||||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
4 A |
Snap On |
-20 °C (-4 °F) |
4 kA |
Interrupting current max at 450 VDC: 10000 A |
Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 °C (140 °F) |
||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
4 A |
Snap On |
-20 °C (-4 °F) |
4 kA |
Handle |
4.173 in (106 mm) |
1.772 in (45 mm) |
IP20 |
4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE |
3 |
60 °C (140 °F) |
Instantaneous |
||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
4 A |
Snap On |
10 kA |
3.535 in (89.8 mm) |
1.386 in (35.2 mm) |
IP20 |
3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm) |
Trip |
2.992 in (76 mm) |
CCC; CE; IMQ; RCM; UL; VDE |
2 |
||||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
400 V |
4 A |
Snap On |
10 kA |
3.535 in (89.8 mm) |
1.386 in (35.2 mm) |
IP20 |
3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm) |
Trip |
2.992 in (76 mm) |
CCC; CE; IMQ; KC; RCM; UL; VDE |
2 |
||||||||||||
|
Omron |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
4 A |
Screw |
-20 °C (-4 °F) |
100 kA |
Rotary Knob |
5.118 in (130 mm) |
1.772 in (45 mm) |
IP20 |
Manual On/Off |
3.728 in (94.7 mm) |
CCC; CE; CUL; IEC; PSE; TUV; UL |
3 |
60 °C (140 °F) |
|||||||||||
|
Omron |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
440 V |
4 A |
Screw |
-20 °C (-4 °F) |
100 kA |
Rocker |
5.118 in (130 mm) |
1.772 in (45 mm) |
IP20 |
Trip |
2.941 in (74.7 mm) |
CCC; CE; CUL; IEC; PSE; TUV; UL |
3 |
60 °C (140 °F) |
|||||||||||
|
|
Schneider Electric Sa |
Thermal Magnetic Circuit Breaker |
DIN Rail And Panel Mount |
690 V |
4 A |
Screw And Snap On |
-20 °C (-4 °F) |
8 kA |
Rotary Handle |
Bulk |
3.504 in (89 mm) |
1.772 in (45 mm) |
IK04; IP20 |
Trip |
3.819 in (97 mm) |
ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL |
3 |
60 °C (140 °F) |
|||||||||
|
|
Phoenix Contact |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
125 V |
4 A |
Screw |
-35 °C (-31 °F) |
5 kA |
Handle |
Bulk |
3.205 in (81.4 mm) |
1.39 in (35.3 mm) |
IP20 |
Trip |
2.587 in (65.7 mm) |
CUL; TUV; UL |
2 |
70 °C (158 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.