5 A Circuit Breaker 42

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

W33-T4B1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

3120-F323-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 A

Rocker

2.126 in (54 mm)

0.827 in (21 mm)

Corrosion Resistant

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

1410-L210-L2F1-S02-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

5 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

W67-X2Q12-5

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

5 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

0.75 in (19.05 mm)

Fungus Resistant; Moisture Resistant

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

Standard

W68-X2Q12-5

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

5 A

Quick Connect

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Fungus Resistant; Moisture Resistant

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

Standard

2CU5L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2D5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

3C5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

2C5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

W33-S1N1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W23-X1A1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

CMB-053-27G3N-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

5 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

TS-709-5

Schurter Ag

Thermal Circuit Breaker

Panel Mount

125 V

32 V

5 A

Quick Connect

1 kA

Push To Reset

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Trip Free

0.886 in (22.5 mm)

UL

1

CA1-B0-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Screw

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

AA1-B0-26-450-1D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

5 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-450-3B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AA1-B0-34-450-5D1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

80 V

5 A

Screw

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

1620-2-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

4230-T120-K0DE-5A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

125 V

5 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

1.39 in (35.3 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

2

70 °C (158 °F)

483-G411-K1M1-A1S0Z--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

3120-N311-P7T1-W02D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N321-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

5SJ4111-7HG42

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

125 V

5 A

Screw And Snap On

10 kA

Handle

4.764 in (121 mm)

0.709 in (18 mm)

IP20; IP40

4.764 x 0.709 x 2.992 in (121 x 18 x 76 mm)

Trip

2.992 in (76 mm)

1

3RV2011-1FA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

BA1-B0-14-450-225-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

80 V

5 A

Screw

-40 °C (-40 °F)

7.5 kA

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL

1

85 °C (185 °F)

W33-S4B1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W57-XB2A99C10-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

0 °C (32 °F)

1 kA

4 s

Push To Reset

1.15 in (29.2 mm)

0.575 in (14.6 mm)

Series Trip

0.89 in (22.6 mm)

1

60 °C (140 °F)

CMB-053-27G3N-W-A/05

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

5 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

102083

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

3RV2011-1FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1FA25

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

DA2-B0-34-450-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

5 A

Screw

-40 °C (-40 °F)

1.5 kA

Toggle Handle

3.612 in (91.75 mm)

1.515 in (38.48 mm)

Moisture Resistant

Series Trip

2.165 in (54.99 mm)

CSA; UL

2

85 °C (185 °F)

1620-3H-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Manual Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

1.189 in (30.2 mm)

1

85 °C (185 °F)

3RV2011-1FA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

5531082

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

250 V

80 V

5 A

Snap On

0 °C (32 °F)

1 kA

Push Button

3.15 in (80 mm)

0.492 in (12.5 mm)

Corrosion/Moisture Resistant; IP20; IP40

Tease-Free And Trip-Free

2.697 in (68.5 mm)

CSA; IEC; UL; VDE

1

55 °C (131 °F)

Medium

483-G411-K1M1-A1S0ZN--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

482-G111-K1M1-A1S1-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

3120-N321-P7T1-W19DG4-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

1110-F112-P1M1-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

-20 °C (-4 °F)

40 A

Rated breaking capacity at 50 VDC: 50 A

Push Button

0.748 in (19 mm)

0.748 in (19 mm)

Corrosion Resistant; IP00; IP40; IP64

Tease-Free And Trip-Free

2.008 in (51 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.