| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Actuator Type | Packing Method | Body Length/Diameter | Body Width | Environmental Characteristics | JESD-609 Code | Dimensions | Circuit Function | Body Height | Reference Standard | No. of Poles | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
-30 °C (-22 °F) |
5 A |
Rocker |
2.126 in (54 mm) |
0.827 in (21 mm) |
Corrosion Resistant |
2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm) |
Manual On/Off |
1.299 in (33 mm) |
CCC; CSA; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Through Hole Mount |
240 V |
28 V |
5 A |
Printed Circuit Board |
-20 °C (-4 °F) |
Silver |
2 kA |
Rated breaking capacity at 50 VDC: 200 A |
Reset Slide |
1.102 in (28 mm) |
0.354 in (9 mm) |
Corrosion Resistant |
e4 |
1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm) |
0.425 in (10.8 mm) |
CSA; UL; VDE |
1 |
70 °C (158 °F) |
||||||
|
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
0.75 in (19.05 mm) |
Fungus Resistant; Moisture Resistant |
2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
Standard |
|||||||
|
|
TE Connectivity |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
2.2 s |
Toggle |
2 in (50.8 mm) |
1.5 in (38.1 mm) |
Fungus Resistant; Moisture Resistant |
2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm) |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
Standard |
|||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.291 in (109 mm) |
1.378 in (35 mm) |
IP20 |
Trip |
2.362 in (60 mm) |
CE, CUL, UL |
2 |
60 °C (140 °F) |
||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
2.067 in (52.5 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
3 |
55 °C (131 °F) |
|||||||||||
|
Altech |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
5 A |
Snap On |
-25 °C (-13 °F) |
10 kA |
Toggle Handle |
Bulk |
4.146 in (105.3 mm) |
1.378 in (35 mm) |
Trip |
2.693 in (68.4 mm) |
CE, CUL, UL |
2 |
55 °C (131 °F) |
|||||||||||
|
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
|
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Screw |
1 kA |
6 s |
Push-Pull |
1.384 in (35.15 mm) |
0.69 in (17.53 mm) |
Corrosion/Environment/Moisture Resistant |
Series Trip |
1.6 in (40.64 mm) |
CSA; UL |
1 |
||||||||||
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Screw |
1 kA |
6 s |
Toggle |
1.384 in (35.15 mm) |
0.69 in (17.53 mm) |
Corrosion/Environment/Moisture Resistant |
Series Trip |
1.6 in (40.64 mm) |
CSA; UL |
1 |
|||||||||||
|
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
5 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
|
Schurter Ag |
Thermal Circuit Breaker |
Panel Mount |
125 V |
32 V |
5 A |
Quick Connect |
1 kA |
Push To Reset |
1.161 in (29.5 mm) |
0.563 in (14.3 mm) |
Trip Free |
0.886 in (22.5 mm) |
UL |
1 |
||||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
5 A |
Stud |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
480 V |
150 V |
5 A |
Screw |
-40 °C (-40 °F) |
10 kA |
Handle |
1.85 in (47 mm) |
0.75 in (19.05 mm) |
Series Trip |
2.5 in (63.5 mm) |
UL |
1 |
85 °C (185 °F) |
|||||||||||
|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||
|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
5 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
277 V |
80 V |
5 A |
Screw |
-40 °C (-40 °F) |
5 kA |
Standards: MIL-PRF-55629, MIL-STD-202 |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.64 in (41.66 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
12 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
150 A |
Modified Reset |
0.524 in (13.3 mm) |
0.276 in (7 mm) |
Corrosion Resistant; IP00; IP50 |
Trip |
0.984 in (25 mm) |
1 |
85 °C (185 °F) |
||||||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
12 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
150 A |
Reset Button |
0.524 in (13.3 mm) |
0.276 in (7 mm) |
Corrosion Resistant; IP00; IP40 |
Trip |
0.984 in (25 mm) |
1 |
85 °C (185 °F) |
|||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
480 V |
125 V |
5 A |
Snap On |
-35 °C (-31 °F) |
5 kA |
Toggle Handle |
3.228 in (82 mm) |
1.39 in (35.3 mm) |
Corrosion Resistant; IP20 |
Trip Free |
2.37 in (60.2 mm) |
UL; TUV |
2 |
70 °C (158 °F) |
||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
5 A |
Screw |
-55 °C (-67 °F) |
2 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.768 in (19.5 mm) |
0.559 in (14.2 mm) |
IP40; IP00 |
Tease-Free And Trip-Free |
1.22 in (31 mm) |
1 |
125 °C (257 °F) |
||||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
1 |
60 °C (140 °F) |
||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
2.22 in (56.4 mm) |
0.984 in (25 mm) |
Corrosion Resistant; IP00; IP40 |
Trip Free |
1.299 in (33 mm) |
CCC; CSA; KC; UL; VDE |
2 |
60 °C (140 °F) |
||||||||
|
|
Siemens |
Thermal Circuit Breaker |
DIN Rail Mount |
400 V |
125 V |
5 A |
Screw And Snap On |
10 kA |
Handle |
4.764 in (121 mm) |
0.709 in (18 mm) |
IP20; IP40 |
4.764 x 0.709 x 2.992 in (121 x 18 x 76 mm) |
Trip |
2.992 in (76 mm) |
1 |
|||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
5 A |
Screw And Snap On |
-20 °C (-4 °F) |
4 kA |
Rotary Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm) |
Trip |
3.819 in (97 mm) |
3 |
60 °C (140 °F) |
||||||||||
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
80 V |
5 A |
Screw |
-40 °C (-40 °F) |
7.5 kA |
Handle |
2 in (50.8 mm) |
0.755 in (19.18 mm) |
Corrosion/Moisture Resistant |
Series Trip |
1.73 in (43.94 mm) |
CSA; UL |
1 |
85 °C (185 °F) |
|||||||||||
|
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
1 kA |
3 s |
Rocker |
1.89 in (48.01 mm) |
0.98 in (24.89 mm) |
Series Trip |
1.724 in (43.79 mm) |
2 |
||||||||||||
|
|
TE Connectivity |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
0 °C (32 °F) |
1 kA |
4 s |
Push To Reset |
1.15 in (29.2 mm) |
0.575 in (14.6 mm) |
Series Trip |
0.89 in (22.6 mm) |
1 |
60 °C (140 °F) |
||||||||||
|
|
Carling Technologies |
Thermal Circuit Breaker |
Panel Mount |
250 V |
32 V |
5 A |
Quick Connect |
-10 °C (14 °F) |
1 kA |
Push To Reset |
1.154 in (29.3 mm) |
0.551 in (14 mm) |
Series Trip |
1.78 in (45.2 mm) |
CSA; CE; CUL; TUV; UL |
1 |
60 °C (140 °F) |
||||||||||
|
|
Eaton Corporation |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
277 V |
48 V |
5 A |
Snap On |
-25 °C (-13 °F) |
15 kA |
Rated breaking capacity at 400 VAC |
IP20; IP40 |
Trip |
CE; CSA; EN; IEC; UL |
1 |
75 °C (167 °F) |
||||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
5 A |
Snap On |
-20 °C (-4 °F) |
4 kA |
Interrupting current max at 450 VDC: 10000 A |
Handle |
3.819 in (97 mm) |
1.772 in (45 mm) |
IP20 |
3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 °C (140 °F) |
||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
5 A |
Snap On |
-20 °C (-4 °F) |
4 kA |
Interrupting current max at 450 VDC: 10000 A |
Handle |
4.173 in (106 mm) |
1.772 in (45 mm) |
IP20 |
4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE |
3 |
60 °C (140 °F) |
||||||||
|
|
Carling Technologies |
Magnetic Circuit Breaker |
Panel Mount |
250 V |
5 A |
Screw |
-40 °C (-40 °F) |
1.5 kA |
Toggle Handle |
3.612 in (91.75 mm) |
1.515 in (38.48 mm) |
Moisture Resistant |
Series Trip |
2.165 in (54.99 mm) |
CSA; UL |
2 |
85 °C (185 °F) |
||||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
12 V |
5 A |
Quick Connect |
-40 °C (-40 °F) |
150 A |
Manual Reset |
0.524 in (13.3 mm) |
0.276 in (7 mm) |
Corrosion Resistant; IP00; IP40 |
Trip |
1.189 in (30.2 mm) |
1 |
85 °C (185 °F) |
||||||||||||
|
|
Siemens |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
690 V |
5 A |
Snap On |
-20 °C (-4 °F) |
4 kA |
Handle |
4.173 in (106 mm) |
1.772 in (45 mm) |
IP20 |
4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm) |
Trip |
3.815 in (96.9 mm) |
ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE |
3 |
60 °C (140 °F) |
Instantaneous |
||||||||
|
|
Phoenix Contact |
Thermal Magnetic Circuit Breaker |
DIN Rail Mount |
250 V |
80 V |
5 A |
Snap On |
0 °C (32 °F) |
1 kA |
Push Button |
3.15 in (80 mm) |
0.492 in (12.5 mm) |
Corrosion/Moisture Resistant; IP20; IP40 |
Tease-Free And Trip-Free |
2.697 in (68.5 mm) |
CSA; IEC; UL; VDE |
1 |
55 °C (131 °F) |
Medium |
||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
5 A |
Screw |
-55 °C (-67 °F) |
2 kA |
Rated breaking capacity at 28 VDC: 6000 A |
Push-Pull |
0.768 in (19.5 mm) |
0.559 in (14.2 mm) |
IP40; IP00 |
Tease-Free And Trip-Free |
1.22 in (31 mm) |
1 |
125 °C (257 °F) |
|||||||||
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
115 V |
28 V |
5 A |
Screw |
-55 °C (-67 °F) |
5 kA |
Push Button |
1.22 in (31 mm) |
0.709 in (18 mm) |
Corrosion/Moisture Resistant; IP00; IP40 |
Trip Free |
1.89 in (48 mm) |
BW; CSA; UL |
1 |
75 °C (167 °F) |
||||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
240 V |
50 V |
5 A |
Quick Connect |
-30 °C (-22 °F) |
5 kA |
Rated breaking capacity at 50 VDC: 1000 A |
Rocker |
Corrosion/Moisture Resistant; IP00; IP40 |
Manual On/Off |
CCC; CE; CSA; CQC; KTL; UL; VDE |
2 |
60 °C (140 °F) |
|||||||||||
|
|
E-t-a Elektrotechnische Apparate |
Thermal Circuit Breaker |
Panel Mount |
250 V |
50 V |
5 A |
Quick Connect |
-20 °C (-4 °F) |
40 A |
Rated breaking capacity at 50 VDC: 50 A |
Push Button |
0.748 in (19 mm) |
0.748 in (19 mm) |
Corrosion Resistant; IP00; IP40; IP64 |
Tease-Free And Trip-Free |
2.008 in (51 mm) |
CSA; CUL; EN; UL; VDE |
1 |
60 °C (140 °F) |
A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.
Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.
In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.