6 A Circuit Breaker 14

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3120-F324-P7T1-W01D-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

6 A

Rocker

2.205 in (56 mm)

0.827 in (21 mm)

Corrosion Resistant

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Manual On/Off

1.299 in (33 mm)

CCC; CSA; UL; VDE

2

60 °C (140 °F)

1C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.146 in (105.3 mm)

0.689 in (17.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

1

55 °C (131 °F)

2C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

1180-01-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

72 V

6 A

Quick Connect

-20 °C (-4 °F)

2 kA

Push Button

1.921 in (48.8 mm)

0.323 in (8.2 mm)

IP00; IP40

0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm)

Trip Free

0.961 in (24.4 mm)

CQC; CSA; EN; IEC; UL; VDE

1

60 °C (140 °F)

J7MN-3R-6

Omron

Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

6 A

Screw

-20 °C (-4 °F)

100 kA

Manual On/Off

3.366 in (85.5 mm)

1.772 in (45 mm)

IP20

3.366 x 1.772 x 3.858 in (85.5 x 45 x 98 mm)

Under Voltage Release

3.858 in (98 mm)

CSA; UL

3

60 °C (140 °F)

5SJ4106-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4106-7HG41

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

4.283 in (108.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

4.283 x 0.693 x 2.748 in (108.8 x 17.6 x 69.8 mm)

Trip

2.748 in (69.8 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

5SY4106-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4106-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

102164

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

5SJ4106-6HG40

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

60 V

6 A

Snap On

-25 °C (-13 °F)

Interrupting current max: 14000 A as per UL/CSA

Handle

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; IP40; Sealed

3.535 x 0.693 x 3.031 in (89.8 x 17.6 x 77 mm)

Trip

3.031 in (77 mm)

CCC; CE; UL; VDE

1

55 °C (131 °F)

5SY4206-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

10 kA

3.535 in (89.8 mm)

1.386 in (35.2 mm)

IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; IMQ; RCM; UL; VDE

2

1019977

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

6 A

Snap On

-35 °C (-31 °F)

5 kA

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

Toggle

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

Trip

2.37 in (60.2 mm)

CUL; IEC 60947-2; TUV; UL

1

70 °C (158 °F)

3120-N321-P7T1-W19DG4-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

2908219

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

6 A

Snap On

-35 °C (-31 °F)

Handle

Bulk

3.378 in (85.8 mm)

0.354 in (9 mm)

Trip

2.587 in (65.7 mm)

CUL; UL

1

70 °C (158 °F)

1610-21-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

32 V

6 A

Tab/Blade

-40 °C (-40 °F)

150 A

Push To Reset

0.787 in (20 mm)

0.236 in (6 mm)

Corrosion Resistant; IP00; IP30; IP54

Trip Free

0.945 in (24 mm)

UL

1

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.