28 V Circuit Breaker 30

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

1410-L210-L2F1-S02-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

2 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1410-L210-L2F1-S02-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

5 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1410-L110-L1F1-S01-1A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

1 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00

Reset Button

0.984 in (25 mm)

0.504 in (12.8 mm)

Corrosion Resistant; Moisture Resistant

e4

0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm)

0.591 in (15 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1658-G21-01-P13-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

15 A

Quick Connect

-20 °C (-4 °F)

1 kA

Push To Reset

Bulk

1.26 in (32 mm)

0.535 in (13.6 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.063 in (27 mm)

CSA; CUL; UL

1

60 °C (140 °F)

413-K14-FN2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-35A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

35 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-70A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

70 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-90A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

90 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-N2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-N2-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

50 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-N2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-N2-70A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

70 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-60A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

60 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K54-N2-70A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

28 V

70 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0Z--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

483-G411-K1M1-A1S0ZN--10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

10 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

0.768 x 0.559 x 1.22 in (19.5 x 14.2 x 31 mm)

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

413-K14-LN2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

30 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-45A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

45 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

483-G411-K1M1-A1S0ZN--20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

20 A

Screw

-55 °C (-67 °F)

2.5 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

1658-G21-02-P10-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

10 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

1658-G21-02-P10-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

20 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

483-G411-K1M1-A1S0ZN--5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

2 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

0.768 in (19.5 mm)

0.559 in (14.2 mm)

IP40; IP00

Tease-Free And Trip-Free

1.22 in (31 mm)

1

125 °C (257 °F)

583-G411-K1M1-A1S0TN-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

200 V

28 V

2 A

Screw

-55 °C (-67 °F)

1 kA

Rated breaking capacity at 28 VDC: 6000 A

Push-Pull

1.89 in (48 mm)

0.78 in (19.8 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.496 in (38 mm)

BW; QPL

3

125 °C (257 °F)

482-G111-K1M1-A1S1-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

50 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

482-G111-K1M1-A1S1-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

5 A

Screw

-55 °C (-67 °F)

5 kA

Push Button

1.22 in (31 mm)

0.709 in (18 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.89 in (48 mm)

BW; CSA; UL

1

75 °C (167 °F)

413-K14-LN2-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

50 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-80A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

80 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

413-K14-LN2-40A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

28 V

40 A

Screw

-55 °C (-67 °F)

6 kA

Push-Pull

1.26 in (32 mm)

0.748 in (19 mm)

Corrosion/Moisture Resistant; IP00; IP40

Tease-Free And Trip-Free

1.929 in (49 mm)

CSA; UL

1

75 °C (167 °F)

3131-AF1PT-000000-000-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

2 A

Quick Connect

-20 °C (-4 °F)

20 A

Rocker

2.008 in (51 mm)

0.945 in (24 mm)

Corrosion Resistant; IP00; IP66

Manual On/Off

1.142 in (29 mm)

UL; VDE

1

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.