Screw And Snap On Circuit Breaker 51

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

2C2UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

2 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

2D20UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

20 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

2D4UM

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

80 V

4 A

Screw And Snap On

-25 °C (-13 °F)

10 kA

Handle

Bulk

3.516 in (89.3 mm)

1.378 in (35 mm)

IP20

Under Voltage Release

2.693 in (68.4 mm)

CSA; UL; VDE

2

55 °C (131 °F)

GV2ME05

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME14

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2ME06

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1.6 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

3RV2021-4FA10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

40 °C (104 °F)

3RV2021-4NA10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

28 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

5SJ4320-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

125 V

20 A

Screw And Snap On

14 kA

Handle

3.543 in (90 mm)

2.126 in (54 mm)

IP20; IP40

3.543 x 2.126 x 2.992 in (90 x 54 x 76 mm)

Trip

2.992 in (76 mm)

3

3RV2311-1HC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

5SJ4111-7HG42

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

125 V

5 A

Screw And Snap On

10 kA

Handle

4.764 in (121 mm)

0.709 in (18 mm)

IP20; IP40

4.764 x 0.709 x 2.992 in (121 x 18 x 76 mm)

Trip

2.992 in (76 mm)

1

3RV2311-1JC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4XA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

59 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2811-1GD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4EA10-0DA0

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4PA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

36 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2031-4VA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

45 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2011-4AA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2821-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4WA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

52 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2811-1HD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2121-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

2.559 in (65 mm)

IP20

3.819 x 2.559 x 3.819 in (97 x 65 x 97 mm)

Relay Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-0JA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-0CA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

250 mA

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4EA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-1FA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2721-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

3RV2021-4BA10

3.819 in (97 mm)

1.772 in (45 mm)

Moisture Resistant; IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

3.815 in (96.9 mm)

CCC; CSA; EAC; KTL; UL

3

60 °C (140 °F)

3RV2011-1HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

450 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

3

60 °C (140 °F)

GV2ME16

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

14 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2ME07

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

2.5 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.118 x 1.772 x 3.504 in (79.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME10

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

6.3 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2ME20

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

18 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2ME143

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.976 in (78.2 x 45 x 101 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

5SY4210-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Screw And Snap On

-25 °C (-13 °F)

5 kA

Environmental Characteristics: Sealed

3.535 in (89.8 mm)

1.386 in (35.2 mm)

Environment/Moisture Resistant; IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CE; CCC; IMQ; RCM; UL; VDE

2

55 °C (131 °F)

3RV2031-4UA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.882 in (140 x 55 x 149.4 mm)

Trip

5.882 in (149.4 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

GV2ME053

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME146

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV3P18

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

18 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Knob

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

CSA; EN; IEC; UL

3

60 °C (140 °F)

GV3P25

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

25 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

GV3P40

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

GV3P50

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

50 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Reference standard: UL

Rotary Handle

Bulk

5.197 in (132 mm)

2.165 in (55 mm)

IK09; IP20

Trip

5.354 in (136 mm)

ABS; ATEX; BV; CSA; CCC; DNV-GL; EAC; EN; IEC; LR0S; UKCA

3

60 °C (140 °F)

GV2ME163

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

14 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.976 in (101 mm)

1.772 in (45 mm)

IK04; IP20

3.976 x 1.752 x 2.646 in (101 x 44.5 x 67.2 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

1019995

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

2

70 °C (158 °F)

1019973

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

2 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

0.693 in (17.6 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC 60947-2; UL

1

70 °C (158 °F)

1020002

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

125 V

10 A

Screw And Snap On

-35 °C (-31 °F)

5 kA

Interrupting current max(DC): 7500 A

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

2

70 °C (158 °F)

GV2P08

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

4 A

Screw And Snap On

-20 °C (-4 °F)

8 kA

Rotary Handle

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.819 in (97 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

GV2P14

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

6 kA

Rotary Handle

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.819 in (97 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.