Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

2DU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

1C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

4.146 in (105.3 mm)

0.689 in (17.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

1

55 °C (131 °F)

2CU5L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2C10UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

3D2UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

2 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

2C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

2DU10L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

3C1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

2DU4L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

4 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2D5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

3C15UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3D8UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

8 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

3C5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

2.067 in (52.5 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

3

55 °C (131 °F)

3B1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

2CU10L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

10 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2DU15L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2C5UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

5 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

2DU8L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

8 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2D4UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

4 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

3D1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3CU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

4230-T120-K0DE-5A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

125 V

5 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

1.39 in (35.3 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

2

70 °C (158 °F)

4230-T130-K0CE-15A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

15 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

2.083 in (52.9 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

3

70 °C (158 °F)

4230-T130-K0CE-1A

E-t-a Elektrotechnische Apparate

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-35 °C (-31 °F)

5 kA

Toggle Handle

3.228 in (82 mm)

2.083 in (52.9 mm)

Corrosion Resistant; IP20

Trip Free

2.37 in (60.2 mm)

UL; TUV

3

70 °C (158 °F)

GA1-B0-20-615-11-DC

Carling Technologies

Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

-40 °C (-40 °F)

3 kA

Handle

3.625 in (92.08 mm)

0.688 in (17.48 mm)

Corrosion/Moisture Resistant

Series Trip

2.62 in (66.55 mm)

CSA, UL

1

85 °C (185 °F)

GA2-B3-11-663-12-MC

Carling Technologies

Magnetic Circuit Breaker

DIN Rail Mount

80 V

63 A

Snap On

-40 °C (-40 °F)

3 kA

Handle

4.188 in (106.38 mm)

1.376 in (34.95 mm)

Corrosion/Moisture Resistant

Series Trip

2.62 in (66.55 mm)

CSA, UL

2

85 °C (185 °F)

410202

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Manual On/Off

3.11 in (79 mm)

IEC

2

70 °C (158 °F)

410215

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

410218

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

50 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

410229

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

32 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

4.205 in (106.8 mm)

Manual On/Off

3.11 in (79 mm)

IEC

4

70 °C (158 °F)

5SY4110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4110-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SJ4106-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4106-7HG41

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

4.283 in (108.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

4.283 x 0.693 x 2.748 in (108.8 x 17.6 x 69.8 mm)

Trip

2.748 in (69.8 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

5SY4106-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4106-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SJ4110-7HG40

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4110-7HG40

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

3.543 in (90 mm)

0.709 in (18 mm)

Environment/Moisture Resistant

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

2907640

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

20 A

Snap On

-35 °C (-31 °F)

10 kA

Bulk

4.567 in (116 mm)

0.693 in (17.6 mm)

2.665 in (67.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

5SY4104-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4104-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CCC; CE; EAC; GOST; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

60139

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

4 A

Snap On

-30 °C (-22 °F)

6 kA

Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Environment/Moisture Resistant; IP20

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; GB; IEC; UL

2

70 °C (158 °F)

5SY4213-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

13 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

5SY4208-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

8 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

102082

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

4 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

5SY4120-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

20 A

Snap On

-25 °C (-13 °F)

5 kA

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; Sealed

3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm)

Trip

3.008 in (76.4 mm)

CCC; CE; IMQ; RCM; UL; VDE

1

55 °C (131 °F)

102083

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

102164

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

102167

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

10 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

5SJ4218-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Environmental Characteristics: Sealed

4.283 in (108.8 mm)

1.386 in (35.2 mm)

Environment Resistant; IP20; IP40

4.283 x 1.386 x 3.031 in (108.8 x 35.2 x 77 mm)

Trip

3.031 in (77 mm)

CCC; CE; UL; VDE

2

55 °C (131 °F)

3RV1011-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP00; IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

4 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.