Siemens Circuit Breaker 87

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

5SY4102-7

Siemens

Thermal Circuit Breaker

Panel Mount

400 V

2 A

Screw

-25 °C (-13 °F)

10 kA

5SY

Sealed Bat

3.543 in (90 mm)

0.709 in (18 mm)

IP20

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Under Voltage Release

2.756 in (70 mm)

CCC; CUL; EN; GOST; IMQ; UL; VDE

1

45 °C (113 °F)

Standard

3RV2021-4FA10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

40 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

40 °C (104 °F)

3RV2021-4NA10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

28 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

5SJ4320-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

125 V

20 A

Screw And Snap On

14 kA

Handle

3.543 in (90 mm)

2.126 in (54 mm)

IP20; IP40

3.543 x 2.126 x 2.992 in (90 x 54 x 76 mm)

Trip

2.992 in (76 mm)

3

3RV2311-1HC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

5SJ4111-7HG42

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

125 V

5 A

Screw And Snap On

10 kA

Handle

4.764 in (121 mm)

0.709 in (18 mm)

IP20; IP40

4.764 x 0.709 x 2.992 in (121 x 18 x 76 mm)

Trip

2.992 in (76 mm)

1

3RV2311-1JC10

Siemens

Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4XA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

59 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2811-1GD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4EA10-0DA0

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2031-4PA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

36 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3VA5120-6ED21-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

250 V

20 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

2 in (50.8 mm)

IP40

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Trip

3 in (76.2 mm)

2

70 °C (158 °F)

3RV2031-4VA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

45 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2011-4AA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2821-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5210-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

3RV2031-4WA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

52 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.512 in (140 mm)

2.165 in (55 mm)

IP00; IP20

5.512 x 2.165 x 5.866 in (140 x 55 x 149 mm)

Trip

5.866 in (149 mm)

3

60 °C (140 °F)

3RV2811-1HD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA6210-5HM31-2AA0

Siemens

Thermal Circuit Breaker

Panel Mount

600 V

100 A

Screw

-25 °C (-13 °F)

35 kA

Toggle

7.8 in (198.12 mm)

4.1 in (104.14 mm)

IP40

7.8 x 4.1 x 3.4 in (198.12 x 104.14 x 86.36 mm)

Trip

3.4 in (86.36 mm)

3

70 °C (158 °F)

3RV2121-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

2.559 in (65 mm)

IP20

3.819 x 2.559 x 3.819 in (97 x 65 x 97 mm)

Relay Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5110-6GC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

3RV2011-0JA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-0CA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

250 mA

Screw And Snap On

-20 °C (-4 °F)

100 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2021-4EA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

32 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2011-1FA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2721-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3VA5210-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

1 KV

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

7.3 in (185.42 mm)

5.5 in (139.7 mm)

IP40

7.3 x 5.5 x 3.3 in (185.42 x 139.7 x 83.82 mm)

Trip

3.3 in (83.82 mm)

4

70 °C (158 °F)

3VA5110-6EC41-0AA0

Siemens

Thermal Circuit Breaker

Panel Mount

690 V

600 V

100 A

Screw

-25 °C (-13 °F)

65 kA

Toggle

5.5 in (139.7 mm)

4 in (101.6 mm)

IP40

5.5 x 4 x 3 in (139.7 x 101.6 x 76.2 mm)

Trip

3 in (76.2 mm)

4

70 °C (158 °F)

5SY4110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4110-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SJ4106-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4106-7HG41

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

4.283 in (108.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

4.283 x 0.693 x 2.748 in (108.8 x 17.6 x 69.8 mm)

Trip

2.748 in (69.8 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

5SY4106-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4106-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SJ4110-7HG40

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4110-7HG40

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

3.543 in (90 mm)

0.709 in (18 mm)

Environment/Moisture Resistant

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

3RV2021-4BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

3RV2021-4BA10

3.819 in (97 mm)

1.772 in (45 mm)

Moisture Resistant; IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

3.815 in (96.9 mm)

CCC; CSA; EAC; KTL; UL

3

60 °C (140 °F)

3RV2011-1HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

450 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

3

60 °C (140 °F)

5SY4104-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4104-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CCC; CE; EAC; GOST; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SY4210-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Screw And Snap On

-25 °C (-13 °F)

5 kA

Environmental Characteristics: Sealed

3.535 in (89.8 mm)

1.386 in (35.2 mm)

Environment/Moisture Resistant; IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CE; CCC; IMQ; RCM; UL; VDE

2

55 °C (131 °F)

5SY4213-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

13 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

5SY4208-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

8 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

5SY4120-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

20 A

Snap On

-25 °C (-13 °F)

5 kA

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; Sealed

3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm)

Trip

3.008 in (76.4 mm)

CCC; CE; IMQ; RCM; UL; VDE

1

55 °C (131 °F)

5SJ4218-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Environmental Characteristics: Sealed

4.283 in (108.8 mm)

1.386 in (35.2 mm)

Environment Resistant; IP20; IP40

4.283 x 1.386 x 3.031 in (108.8 x 35.2 x 77 mm)

Trip

3.031 in (77 mm)

CCC; CE; UL; VDE

2

55 °C (131 °F)

3RV1011-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP00; IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

4 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1FA25

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1DA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1HA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV1011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.