Circuit Breaker

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

2DU8L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

8 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

1.378 in (35 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

2

60 °C (140 °F)

2D4UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

4 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

3D1UR

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

480 V

1 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle

Bulk

3.516 in (89.3 mm)

2.067 in (52.5 mm)

IP20

Trip

2.693 in (68.4 mm)

CE; CUL; UL

3

55 °C (131 °F)

3CU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

6-1393250-7

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

1 kA

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

W28-XT1A-3

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

2.2 s

Push To Reset

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

1

W58-XC4C12A-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Lug

1 kA

10 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

W33-S1N1Q-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W33-S1N1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

1110-F112-P1M1-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

2 A

Quick Connect

-20 °C (-4 °F)

1 kA

ENVIRONMENTAL CHARACTERISTICS: IP40; IP00

Push Button

0.748 in (19 mm)

0.52 in (13.2 mm)

Corrosion Resistant; Moisture Resistant

0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm)

Tease-Free And Trip-Free

1.87 in (47.5 mm)

CBE; CSA; IEC; UL; VDE

1

60 °C (140 °F)

Medium

GV2ME05

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

GV2ME14

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

10 A

Screw And Snap On

-20 °C (-4 °F)

3 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

3.079 x 1.772 x 3.504 in (78.2 x 45 x 89 mm)

Trip

3.091 in (78.5 mm)

ATEX; BV; CCC; CSA; DNV-GL; EAC; EN; IEC; LROS; RINA; UL

3

60 °C (140 °F)

W91-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

1

85 °C (185 °F)

W92-X112-30

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

30 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Moisture Resistant

Series Trip

1.985 in (50.42 mm)

CSA; UL; VDE

2

85 °C (185 °F)

Standard

W92-X112-40

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

40 A

Stud

-40 °C (-40 °F)

5 kA

2.2 s

Toggle

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Series Trip

1.845 in (46.86 mm)

2

85 °C (185 °F)

W93-X112-40V

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

250 V

40 A

Stud

-40 °C (-40 °F)

2 kA

2.2 s

Toggle

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Series Trip

1.845 in (46.86 mm)

3

85 °C (185 °F)

W23-X1A1G-50

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W23-X1A1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-15

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-25

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

25 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

1410-L110-L1F1-S01-1A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

1 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00

Reset Button

0.984 in (25 mm)

0.504 in (12.8 mm)

Corrosion Resistant; Moisture Resistant

e4

0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm)

0.591 in (15 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1180-01-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

72 V

6 A

Quick Connect

-20 °C (-4 °F)

2 kA

Push Button

1.921 in (48.8 mm)

0.323 in (8.2 mm)

IP00; IP40

0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm)

Trip Free

0.961 in (24.4 mm)

CQC; CSA; EN; IEC; UL; VDE

1

60 °C (140 °F)

J7MN-3R-6

Omron

Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

6 A

Screw

-20 °C (-4 °F)

100 kA

Manual On/Off

3.366 in (85.5 mm)

1.772 in (45 mm)

IP20

3.366 x 1.772 x 3.858 in (85.5 x 45 x 98 mm)

Under Voltage Release

3.858 in (98 mm)

CSA; UL

3

60 °C (140 °F)

W67-X2T52-50

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

50 A

Screw

2.2 s

Toggle

Series Trip

1

GV2ME06

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail And Panel Mount

690 V

1.6 A

Screw And Snap On

-20 °C (-4 °F)

100 kA

Push Button

Bulk

3.504 in (89 mm)

1.772 in (45 mm)

IK04; IP20

Trip

3.091 in (78.5 mm)

EN; IEC

3

60 °C (140 °F)

CMB-033-27J6N-B-D/03

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

3 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

CMB-053-27G3N-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

5 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

CMB-153-11C3N-B-A/15

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

15 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

CMB-153-11C3N-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

15 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

CMB-203-27J8N-B-A/20

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

20 A

Quick Connect

-10 °C (14 °F)

1 kA

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Manual On/Off

1.78 in (45.2 mm)

1

60 °C (140 °F)

TS-709-5

Schurter Ag

Thermal Circuit Breaker

Panel Mount

125 V

32 V

5 A

Quick Connect

1 kA

Push To Reset

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Trip Free

0.886 in (22.5 mm)

UL

1

CLB-103-27E3N-W-A/10

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; CSA; TUV; UL

1

60 °C (140 °F)

AA1-B0-26-430-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

3 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

CA1-B0-12-225-321-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

250 mA

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-16-625-622-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

25 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-26-210-412-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

100 mA

Stud

-40 °C (-40 °F)

5 kA

Handle

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Corrosion/Moisture Resistant

Series Trip

1.85 in (47 mm)

CSA; UL; VDE

1

85 °C (185 °F)

CA1-B0-32-410-311-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

1 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-32-810-AG2-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

100 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B0-46-625-622-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

25 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-12-610-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-12-610-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-12-610-121-MG

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

80 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-12-620-321-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

20 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA1-B2-34-450-A21-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

5 A

Screw

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

CA2-B0-34-615-121-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

150 V

15 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

1.515 in (38.48 mm)

Series Trip

2.5 in (63.5 mm)

UL

2

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.