Inline/Holder Fuses 1,479

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

235002

Littelfuse

Electric Fuse

Inline/Holder

250 V

2 A

End Cap

2.649 J

-55 °C (-67 °F)

Nickel

100 A

4 h

2.6

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

250 V

60.3 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

235005

Littelfuse

Electric Fuse

Inline/Holder

125 V

5 A

End Cap

27.411 J

-55 °C (-67 °F)

10 kA

4 h

27.41

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

125 V

18.4 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

235006

Littelfuse

Electric Fuse

Inline/Holder

125 V

6 A

End Cap

47.324 J

-55 °C (-67 °F)

Nickel

10 kA

4 h

47.325

Bulk; Tape And Reel

0.205 in (5.2 mm)

Supplemental

125 V

14.8 mΩ

0.197 x 0.787 in (5 x 20 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; KTL; PSE; UL

125 °C (257 °F)

Fast

D0Z14G16

Littelfuse

Electric Fuse

Inline/Holder

380 V

250 V

16 A

End Cap

50 kA

D0Z1

Rated Breaking Capacity at 250 VDC: 50000 A

0.433 in (11 mm)

Indicator

0.433 x 1.417 in (11 x 36 mm)

1.417 in (36 mm)

DIN; IEC; VDE

Fast

D0Z14G4

Littelfuse

Electric Fuse

Inline/Holder

380 V

250 V

4 A

End Cap

50 kA

D0Z1

Rated Breaking Capacity at 250 VDC: 50000 A

0.433 in (11 mm)

Indicator

0.433 x 1.417 in (11 x 36 mm)

1.417 in (36 mm)

DIN; IEC; VDE

Fast

D0Z14G6

Littelfuse

Electric Fuse

Inline/Holder

380 V

250 V

6 A

End Cap

50 kA

D0Z1

Rated Breaking Capacity at 250 VDC: 50000 A

0.433 in (11 mm)

Indicator

0.433 x 1.417 in (11 x 36 mm)

1.417 in (36 mm)

DIN; IEC; VDE

Fast

D0Z18G63

Littelfuse

Electric Fuse

Inline/Holder

380 V

250 V

63 A

End Cap

50 kA

D0Z1

Rated Breaking Capacity at 250 VDC: 50000 A

0.591 in (15 mm)

Indicator

0.591 x 1.417 in (15 x 36 mm)

1.417 in (36 mm)

DIN; IEC; VDE

Fast

ATMR25

Mersen S A

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

200 kA

Rated Breaking Capacity = 33.75A-10kA

Bulk

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

CSA; UL

Fast

ATQ15

Mersen S A

Electric Fuse

Inline/Holder

500 V

15 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ1

Mersen S A

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

ATQ8

Mersen S A

Electric Fuse

Inline/Holder

500 V

8 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

SLC015

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

100 kA

0.406 in (10.3 mm)

0.406 x 1.406 in (10.3 x 35.7 mm)

1.406 in (35.7 mm)

CSA; UL

Medium Time Delay

LA100URD73LI1000

Littelfuse

Electric Fuse

Inline/Holder

1.1 KV

1 kA

Tab/Blade

370 J

100 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

LA100URD73TTI1000

Littelfuse

Electric Fuse

Inline/Holder

1.1 KV

1 kA

End Cap

370 J

100 kA

LA

UL

Very Fast

997005

Littelfuse

Electric Fuse

Inline/Holder

58 V

5 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

997010

Littelfuse

Electric Fuse

Inline/Holder

58 V

10 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

997015

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

20100500001P

Littelfuse

Electric Fuse

Inline/Holder

250 V

50 mA

End Cap

9 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

15GSE100E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 21.915 in (76.2 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15GSE65E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

65 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 21.915 in (76.2 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15GSE80E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

80 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 21.915 in (76.2 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15GSE2125E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

125 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 21.915 in (162.05 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15GSE2150E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 21.915 in (162.05 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15GSE2175E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

175 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 21.915 in (162.05 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15GSE2200E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

200 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 21.915 in (162.05 x 556.63 mm)

21.875 in (555.63 mm)

Medium

15NLE100E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE10E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

10 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE15E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

15 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE20E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

20 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE25E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

25 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE30E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

30 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE40E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

40 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE50E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

50 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE65E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

65 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE80E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

80 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE2100E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

100 A

End Cap

60 kA

5 m

6.382 in (162.1 mm)

Striker

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE2125E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

125 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE2150E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE2175E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

175 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE2200E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

200 A

End Cap

60 kA

10 m

6.382 in (162.1 mm)

Striker

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE280E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

80 A

End Cap

60 kA

5 m

6.382 in (162.1 mm)

Striker

6.38 x 23.875 in (162.05 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE3150E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

150 A

End Cap

60 kA

10 m

9.752 in (247.7 mm)

Striker

9.75 x 23.875 in (247.65 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE3175E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

175 A

End Cap

60 kA

10 m

9.752 in (247.7 mm)

Striker

9.75 x 23.875 in (247.65 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE3250E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

250 A

End Cap

60 kA

10 m

9.752 in (247.7 mm)

Striker

9.75 x 23.875 in (247.65 x 606.43 mm)

23.875 in (606.43 mm)

Medium

15NLE3300E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

300 A

End Cap

60 kA

10 m

9.752 in (247.7 mm)

Striker

9.75 x 23.875 in (247.65 x 606.43 mm)

23.875 in (606.43 mm)

Medium

5NLE100E

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

100 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

5NLE10E

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

10 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

5NLE125E

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

125 A

End Cap

80 kA

10 m

3 in (76.2 mm)

Striker

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.