| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
35 A |
Tab/Blade |
-40 °C (-40 °F) |
Tin |
1 kA |
100 ms |
Bulk |
0.752 in (19.1 mm) |
0.201 in (5.1 mm) |
e3 |
32 V |
0.752 x 0.201 x 0.483 in (19.1 x 5.1 x 12.28 mm) |
0.483 in (12.28 mm) |
UL |
100 °C (212 °F) |
Fast |
||||||||||
|
|
KYOCERA AVX |
Electric Fuse |
Surface Mount |
32 V |
32 V |
500 mA |
Wraparound |
300 μJ |
-55 °C (-67 °F) |
Tin with Nickel barrier |
50 A |
Tape And Reel, 7 inch |
0.039 in (1 mm) |
0.022 in (0.55 mm) |
e3 |
0402 |
0.039 x 0.022 x 0.016 in (1 x 0.55 x 0.4 mm) |
0.016 in (0.4 mm) |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
64 V |
2 A |
Wraparound |
4.7 J |
-55 °C (-67 °F) |
Tin |
50 A |
FCD12 |
Tape And Reel |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e3 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
25 A |
0.236 in (6 mm) |
32 V |
0.236 x 0.984 in (6 x 25 mm) |
0.984 in (25 mm) |
|||||||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
8 A |
0.236 in (6 mm) |
32 V |
0.236 x 0.984 in (6 x 25 mm) |
0.984 in (25 mm) |
|||||||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
5 A |
0.236 in (6 mm) |
32 V |
0.236 x 0.984 in (6 x 25 mm) |
0.984 in (25 mm) |
|||||||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
32 V |
32 V |
16 A |
0.236 in (6 mm) |
32 V |
0.236 x 0.984 in (6 x 25 mm) |
0.984 in (25 mm) |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
64 V |
500 mA |
Wraparound |
930 μJ |
-55 °C (-67 °F) |
Tin |
50 A |
FCD12 |
Tape And Reel |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e3 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
64 V |
1 A |
Wraparound |
5.6 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
FCD12 |
Tape And Reel |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e3 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
64 V |
1.25 A |
Wraparound |
10 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
FCD12 |
Tape And Reel |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e3 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
64 V |
2.5 A |
Wraparound |
78 mJ |
-55 °C (-67 °F) |
Tin |
50 A |
FCD12 |
Tape And Reel |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
e3 |
0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm) |
0.024 in (0.6 mm) |
IEC; UL |
125 °C (257 °F) |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Surface Mount |
32 V |
32 V |
5 A |
Wraparound |
1.6 J |
-55 °C (-67 °F) |
Tin Lead Over Nickel |
35 A |
431 |
Rated Breaking Capacity at 32 VDC: 35 A |
0.063 in (1.6 mm) |
0.031 in (0.79 mm) |
e0 |
0.063 x 0.031 x 0.018 in (1.6 x 0.79 x 0.46 mm) |
0.018 in (0.46 mm) |
CSA; UL |
90 °C (194 °F) |
Very Fast |
|||||||||||
|
|
Schurter Ag |
Electric Fuse |
Surface Mount |
32 V |
125 V |
5 A |
Wraparound |
140 mJ |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 32 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
32 V |
5 s |
1206 |
0.061 in (1.55 mm) |
CUL, UL |
125 °C (257 °F) |
Very Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.