32 V Fuses 13

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK/ATC-35

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

35 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

32 V

0.752 x 0.201 x 0.483 in (19.1 x 5.1 x 12.28 mm)

0.483 in (12.28 mm)

UL

100 °C (212 °F)

Fast

F0402E0R50FSTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

500 mA

Wraparound

300 μJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.022 in (0.55 mm)

e3

0402

0.039 x 0.022 x 0.016 in (1 x 0.55 x 0.4 mm)

0.016 in (0.4 mm)

125 °C (257 °F)

Fast

FCD121200TP

Littelfuse

Electric Fuse

Surface Mount

32 V

64 V

2 A

Wraparound

4.7 J

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

GBC25

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

25 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

GBC8

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

8 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

GBC5

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

5 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

GBC16

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

16 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

FCD120500TP

Littelfuse

Electric Fuse

Surface Mount

32 V

64 V

500 mA

Wraparound

930 μJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

FCD121100TP

Littelfuse

Electric Fuse

Surface Mount

32 V

64 V

1 A

Wraparound

5.6 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

FCD121125TP

Littelfuse

Electric Fuse

Surface Mount

32 V

64 V

1.25 A

Wraparound

10 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

FCD121250TP

Littelfuse

Electric Fuse

Surface Mount

32 V

64 V

2.5 A

Wraparound

78 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

431005

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

5 A

Wraparound

1.6 J

-55 °C (-67 °F)

Tin Lead Over Nickel

35 A

431

Rated Breaking Capacity at 32 VDC: 35 A

0.063 in (1.6 mm)

0.031 in (0.79 mm)

e0

0.063 x 0.031 x 0.018 in (1.6 x 0.79 x 0.46 mm)

0.018 in (0.46 mm)

CSA; UL

90 °C (194 °F)

Very Fast

3-103-129

Schurter Ag

Electric Fuse

Surface Mount

32 V

125 V

5 A

Wraparound

140 mJ

-55 °C (-67 °F)

50 A

Rated Breaking Capacity at 32 VDC: 300 A

Tape

0.126 in (3.2 mm)

0.061 in (1.55 mm)

32 V

5 s

1206

0.061 in (1.55 mm)

CUL, UL

125 °C (257 °F)

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.