1 A Fuses 39

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

38211000410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

4.85 J

-40 °C (-40 °F)

Matte Tin

100 A

150 ms

3

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38211000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

4.85 J

-40 °C (-40 °F)

Tin

100 A

150 ms

3

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

80411000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

20 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

CQC; IEC; VDE; PSE

125 °C (257 °F)

Time Lag

80411000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

20 J

-40 °C (-40 °F)

Matte Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

CQC; IEC; VDE; PSE

125 °C (257 °F)

Time Lag

276001

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

1 A

Pin Wire

-55 °C (-67 °F)

50 A

276

Rated Breaking Capacity at 125 VDC: 300 A

0.093 in (2.36 mm)

0.093 x 0.28 in (2.36 x 7.11 mm)

0.28 in (7.11 mm)

CSA; UL

125 °C (257 °F)

Very Fast

80811000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1 A

Pin Wire

6.6 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.0066

Ammo Pack; Tape And Reel

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80811000075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1 A

Pin Wire

6.6 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.0066

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80811000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1 A

Pin Wire

6.6 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.0066

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80711000000

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1 A

Wire

20 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

80711000440

Littelfuse

Electric Fuse

Through Hole Mount

300 V

300 V

1 A

Wire

20 kJ

-40 °C (-40 °F)

Tin

100 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

300 V

0.488 x 0.252 x 0.362 in (12.4 x 6.4 x 9.2 mm)

0.362 in (9.2 mm)

IEC; CUL; PSE; UL

125 °C (257 °F)

Time Lag

0508001MXP

Littelfuse

Electric Fuse

Inline/Holder

1 KV

1 KV

1 A

End Cap

449 mJ

-55 °C (-67 °F)

10 kA

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE; CUL; UL

125 °C (257 °F)

20111000001P

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

2 J

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20111000021P

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

2 J

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20111000431P

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Pin Wire

2 J

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Tape And Reel

0.232 in (5.9 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.827 in (21 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

KLC1

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

LA120X1-1

Littelfuse

Electric Fuse

Inline/Holder

1.2 KV

1 KV

1 A

End Cap

7.5 J

100 kA

Rated Breaking Capacity at 1000 VDC: 100000 A

0.811 in (20.6 mm)

1.2 KV

0.811 x 4.606 in (20.6 x 117 mm)

4.606 in (117 mm)

Very Fast

LA15QS1-2

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

1 A

End Cap

200 μJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

CY10X38G1

Littelfuse

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Fast

CY10X38M1

Littelfuse

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

120 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC

Time Lag

ATQ1

Mersen S A

Electric Fuse

Inline/Holder

500 V

1 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

39711000000

Littelfuse

Electric Fuse

Through Hole Mount

125 V

1 A

Pin Wire

4.85 J

-40 °C (-40 °F)

Tin

50 A

3 m 20 s

3.5

Ammo Pack; Tape And Reel

0.335 in (8.5 mm)

0.315 in (8 mm)

e3

125 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.157 in (4 mm)

CUL; UL

125 °C (257 °F)

Slow

39711000440

Littelfuse

Electric Fuse

Through Hole Mount

125 V

1 A

Pin Wire

4.85 J

-40 °C (-40 °F)

Tin

50 A

3 m 20 s

3.5

Bulk

0.335 in (8.5 mm)

0.315 in (8 mm)

e3

125 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.157 in (4 mm)

CUL; UL

125 °C (257 °F)

Slow

429001

Littelfuse

Electric Fuse

Surface Mount

63 V

63 V

1 A

Wraparound

35 mJ

-55 °C (-67 °F)

Tin Lead Over Nickel

50 A

200 ms

Pre Arcing Time: Open within 0.2 s at 300% Rated Current

0.035

0.125 in (3.18 mm)

0.06 in (1.52 mm)

e0

63 V

99.5 mΩ

1206

0.125 x 0.06 x 0.045 in (3.18 x 1.52 x 1.14 mm)

0.045 in (1.14 mm)

CSA; UL

125 °C (257 °F)

Very Fast

ATM1

Mersen S A

Electric Fuse

Inline/Holder

600 V

600 V

1 A

End Cap

100 kA

Rated Breaking Capacity at 500 VDC: 100000 A

0.394 in (10 mm)

600 V

Midget

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Fast

C1S1

Bel Fuse

Electric Fuse

Surface Mount

63 V

63 V

1 A

Wraparound

121 mJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

2 ms

Pre-Arcing Time: Open within 0.002 s, at 800% Rated Current

Tape And Reel

0.126 in (3.2 mm)

0.062 in (1.58 mm)

e3

63 V

1206

0.126 x 0.062 x 0.023 in (3.2 x 1.58 x 0.58 mm)

0.023 in (0.58 mm)

CE; CUL; UL

125 °C (257 °F)

Slow

FCD121100TP

Littelfuse

Electric Fuse

Surface Mount

32 V

64 V

1 A

Wraparound

5.6 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

288001

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

2.22 J

35 A

288

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; MIL; PSE; UL

Fast

02200044DRT1P

Littelfuse

Electric Fuse

1 A

-55 °C (-67 °F)

Matte Tin

100 A

4 h

2.22

0.177 in (4.5 mm)

Supplemental

e3

350 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CE, CSA, PSE, UL

125 °C (257 °F)

37411000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Pin Wire

3.1 J

-40 °C (-40 °F)

Tin

50 A

1 m

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA, UL

85 °C (185 °F)

Time Lag

37311000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Pin Wire

125 mJ

-40 °C (-40 °F)

Tin

50 A

5 s

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA; CUL; UL

85 °C (185 °F)

Very Fast

37211000511

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Pin Wire

7.5 J

-40 °C (-40 °F)

Matte Tin

35 A

20 ms

5.5

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; KC; PSE; UL; VDE

85 °C (185 °F)

Time Lag

0680L1000-25

Bel Fuse

Electric Fuse

Surface Mount

125 V

125 V

1 A

Wraparound

1.5 J

-55 °C (-67 °F)

Palladium

50 A

10 ms

Rated Breaking Capacity at 125 VDC: 100 A

Tape And Reel, 13 inch

0.24 in (6.1 mm)

0.1 in (2.54 mm)

e4

125 V

2410

0.1 in (2.54 mm)

CUL; TUV; UL

125 °C (257 °F)

Time Lag

0603TSFV100FM/65-2

Littelfuse

Electric Fuse

1 A

-55 °C (-67 °F)

Tin/Nickel

50 A

4 h

0.03

0.067 in (1.7 mm)

0.036 in (0.91 mm)

e2

65 V

0603

0.067 x 0.036 x 0.016 in (1.7 x 0.91 x 0.4 mm)

0.016 in (0.4 mm)

90 °C (194 °F)

Fast

FM08A125V1AT

Eaton Corporation

Electric Fuse

Through Hole Mount

125 V

1 A

Pin Wire

300 A

Pre Arcing Time: Open within 0.1 s at 300% Rated Current

0.103 in (2.62 mm)

0.103 x 0.311 in (2.62 x 7.9 mm)

0.311 in (7.9 mm)

MIL-PRF-23419/8J

3-103-105

Schurter Ag

Electric Fuse

Surface Mount

125 V

125 V

1 A

Wraparound

4.8 mJ

-55 °C (-67 °F)

50 A

Rated Breaking Capacity at 125 VDC: 300 A

Tape

0.126 in (3.2 mm)

0.061 in (1.55 mm)

125 V

5 s

1206

0.061 in (1.55 mm)

CUL, UL

125 °C (257 °F)

Very Fast

24111000021

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

4.5 J

-25 °C (-13 °F)

80 A

Bulk

0.205 in (5.2 mm)

5 ms

0.197 x 0.984 in (5 x 25 mm)

Indicator

0.984 in (25 mm)

70 °C (158 °F)

Medium Time Lag

30311000421

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 V

1 A

Pin Wire

39 mJ

-25 °C (-13 °F)

50 A

1 m

Pre Arcing Time: Open within 60 s at 200% Rated Current

Bulk

0.236 in (6 mm)

0.315 in (8 mm)

CSA; UL

70 °C (158 °F)

Fast

30311000131

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 V

1 A

Pin Wire

39 mJ

-25 °C (-13 °F)

50 A

1 m

Pre Arcing Time: Open within 60 s at 200% Rated Current

Bulk

0.236 in (6 mm)

0.315 in (8 mm)

CSA; UL

70 °C (158 °F)

Fast

37011000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Pin Wire

200 mJ

-40 °C (-40 °F)

Tin

35 A

20 ms

Ammo Pack; Tape

0.335 in (8.5 mm)

e3

TR5

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.