15 A Fuses 23

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BP/ATM-15-RP

Eaton Corporation

Electric Fuse

15 A

Tab/Blade

-40 °C (-40 °F)

Silver

1 kA

0.43 in (10.92 mm)

0.15 in (3.81 mm)

e4

32 V

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

UL

100 °C (212 °F)

Fast

KLK15

Littelfuse

Electric Fuse

Inline/Holder

600 V

500 V

15 A

End Cap

100 kA

2 m

Pre Arcing Time: Open within 120 s at 200% Rated Current

0.406 in (10.31 mm)

600 V

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

CSA; QPL; UL

Fast

KLC15

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

LA100P15-1

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

15 A

End Cap

600 mJ

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

0.559 in (14.2 mm)

0.559 x 2.63 in (14.2 x 66.8 mm)

2.63 in (66.8 mm)

UL

Very Fast

LA120X15-1

Littelfuse

Electric Fuse

Inline/Holder

1.2 KV

1 KV

15 A

End Cap

2.1 kJ

100 kA

Rated Breaking Capacity at 1000 VDC: 100000 A

0.811 in (20.6 mm)

1.2 KV

0.811 x 4.606 in (20.6 x 117 mm)

4.606 in (117 mm)

Very Fast

LA15QS15-2

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

15 A

End Cap

42 mJ

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

0.409 in (10.4 mm)

0.409 x 1.5 in (10.4 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

LA60Q15-2

Littelfuse

Electric Fuse

Inline/Holder

600 V

600 V

15 A

End Cap

180 J

200 kA

Rated Breaking Capacity at 600 VDC: 100000 A

0.406 in (10.32 mm)

0.406 x 1.5 in (10.32 x 38.1 mm)

1.5 in (38.1 mm)

UL

Very Fast

ATQ15

Mersen S A

Electric Fuse

Inline/Holder

500 V

15 A

End Cap

10 kA

0.394 in (10 mm)

500 V

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

CSA; UL

Time Delay

SLC015

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

100 kA

0.406 in (10.3 mm)

0.406 x 1.406 in (10.3 x 35.7 mm)

1.406 in (35.7 mm)

CSA; UL

Medium Time Delay

997015

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

15NLE15E

Littelfuse

Electric Fuse

Inline/Holder

15.5 KV

15 A

End Cap

60 kA

5 m

3 in (76.2 mm)

Striker

3 x 23.875 in (76.2 x 606.43 mm)

23.875 in (606.43 mm)

Medium

5NLE15E

Littelfuse

Electric Fuse

Inline/Holder

5.5 KV

15 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 17.875 in (76.2 x 454.03 mm)

17.875 in (454.03 mm)

Medium

8NLE15E

Littelfuse

Electric Fuse

Inline/Holder

8.25 KV

15 A

End Cap

80 kA

5 m

3 in (76.2 mm)

Striker

3 x 17.87 in (76.2 x 453.89 mm)

17.875 in (454.03 mm)

Medium

FLA15

Littelfuse

Electric Fuse

Inline/Holder

125 V

15 A

End Cap

10 kA

0.406 in (10.31 mm)

Indicator

0.406 x 1.5 in (10.31 x 38.1 mm)

1.5 in (38.1 mm)

UL

Slow

4192150000

Littelfuse

Electric Fuse

Surface Mount

65 V

65 V

15 A

End Cap

103 J

-65 °C (-85 °F)

Silver

50 A

Tape And Reel

0.24 in (6.1 mm)

0.109 in (2.77 mm)

e4

30 s

0.24 x 0.109 x 0.109 in (6.1 x 2.77 x 2.77 mm)

0.109 in (2.77 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LVSP0015TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

3.267 kJ

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

LVSP0015TXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

Tab/Blade

3.267 kJ

Nickel

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

0453015MR

Littelfuse

Electric Fuse

Surface Mount

65 V

65 V

15 A

Wraparound

97.82 J

-55 °C (-67 °F)

Silver

50 A

Tape And Reel

0.24 in (6.1 mm)

0.106 in (2.69 mm)

e4

65 V

Nano

0.106 in (2.69 mm)

CSA; CUL; UL

125 °C (257 °F)

Very Fast

ITV4030L0415NR

Littelfuse

Electric Fuse

Surface Mount

36 V

15 A

Wraparound

-10 °C (14 °F)

50 A

Tape And Reel, 13 inch

0.157 in (4 mm)

0.118 in (3 mm)

36 V

0.035 in (0.9 mm)

CUL; TUV; UL

65 °C (149 °F)

PF-ET1-15

Bourns

Electric Fuse

Inline/Holder

1 KV

15 A

Tab/Blade

365 J

-55 °C (-67 °F)

20 kA

4 m

Tray

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PF-EC1-15

Bourns

Electric Fuse

Inline/Holder

1 KV

15 A

End Cap

365 J

-55 °C (-67 °F)

20 kA

4 m

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PF-HC1-15

Bourns

Electric Fuse

Inline/Holder

600 V

600 V

15 A

End Cap

51.64 J

-55 °C (-67 °F)

150 kA

4 m

Rated Breaking Capacity at 600 VDC: 10000 A

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; TUV; UL

125 °C (257 °F)

15SRC250

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

0.8 in (20.32 mm)

2.97 in (75.43 mm)

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.