| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Altech |
Electric Fuse |
Inline/Holder |
500 V |
400 A |
Tab/Blade |
Bulk |
2.559 in (65 mm) |
2.087 in (53 mm) |
2.362 in (60 mm) |
Slow |
|||||||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
23 J |
200 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
23 J |
200 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
End Cap |
23 J |
200 kA |
1.575 in (40 mm) |
1.575 in (40 mm) |
Indicator |
1.575 x 1.575 x 1.929 in (40 x 40 x 49 mm) |
1.929 in (49 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
19 J |
200 kA |
2.008 in (51 mm) |
2.008 in (51 mm) |
Indicator |
2.008 x 2.008 x 1.874 in (51 x 51 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
19 J |
200 kA |
2.008 in (51 mm) |
2.008 in (51 mm) |
Indicator |
2.008 x 2.008 x 1.874 in (51 x 51 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
End Cap |
19 J |
200 kA |
2 in (50.8 mm) |
2 in (50.8 mm) |
Indicator |
2 x 2 x 1.929 in (50.8 x 50.8 x 49 mm) |
1.929 in (49 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
15 J |
200 kA |
2.362 in (60 mm) |
2.362 in (60 mm) |
Indicator |
2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
Tab/Blade |
15 J |
200 kA |
2.362 in (60 mm) |
2.362 in (60 mm) |
Indicator |
2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm) |
1.874 in (47.6 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
400 A |
End Cap |
15 J |
200 kA |
2.374 in (60.3 mm) |
2.374 in (60.3 mm) |
Indicator |
2.374 x 2.374 x 1.929 in (60.3 x 60.3 x 49 mm) |
1.929 in (49 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
750 V |
400 A |
Tab/Blade |
290 J |
100 kA |
Rated Breaking Capacity at 750 VDC: 100000 A |
2 in (50.8 mm) |
Indicator |
2 x 3.469 in (50.8 x 88.1 mm) |
3.469 in (88.1 mm) |
UL |
Very Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1 KV |
750 V |
400 A |
Tab/Blade |
290 J |
100 kA |
Rated Breaking Capacity at 750 VDC: 100000 A |
2 in (50.8 mm) |
2 x 3.469 in (50.8 x 88.1 mm) |
3.469 in (88.1 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
400 A |
Tab/Blade |
38 J |
100 kA |
2.008 in (51 mm) |
2.008 in (51 mm) |
Indicator |
2.008 x 2.008 x 2.854 in (51 x 51 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
400 A |
Tab/Blade |
32 J |
100 kA |
2.362 in (60 mm) |
2.362 in (60 mm) |
Indicator |
2.362 x 2.362 x 2.854 in (60 x 60 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
400 A |
Tab/Blade |
25 J |
100 kA |
2.933 in (74.5 mm) |
2.933 in (74.5 mm) |
Indicator |
2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm) |
2.854 in (72.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
400 A |
Tab/Blade |
40 J |
100 kA |
Rated Breaking Capacity at 150 VDC: 100000 A |
1.13 in (28.7 mm) |
Indicator |
1.13 x 1.161 in (28.7 x 29.5 mm) |
1.161 in (29.5 mm) |
UL |
Very Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
150 V |
150 V |
400 A |
Tab/Blade |
40 J |
100 kA |
Rated Breaking Capacity at 150 VDC: 100000 A |
1.13 in (28.7 mm) |
1.13 x 1.161 in (28.7 x 29.5 mm) |
1.161 in (29.5 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
300 V |
400 A |
Tab/Blade |
83 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.5 in (38.1 mm) |
Indicator |
1.5 x 1.579 in (38.1 x 40.1 mm) |
1.579 in (40.1 mm) |
UL |
Very Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
300 V |
400 A |
Tab/Blade |
83 J |
200 kA |
Rated Breaking Capacity at 300 VDC: 20000 A |
1.5 in (38.1 mm) |
1.5 x 1.579 in (38.1 x 40.1 mm) |
1.579 in (40.1 mm) |
UL |
Very Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
400 A |
Tab/Blade |
98 J |
200 kA |
Rated Breaking Capacity at 500 VDC: 100000 A |
1.5 in (38.1 mm) |
500 V |
1.5 x 2.091 in (38.1 x 53.1 mm) |
2.091 in (53.1 mm) |
CSA; UL |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
700 V |
400 A |
Tab/Blade |
99 J |
200 kA |
Rated Breaking Capacity at 700 VDC: 100000 A |
1.5 in (38.1 mm) |
1.5 x 2.843 in (38.1 x 72.2 mm) |
2.843 in (72.2 mm) |
CSA; UL |
Fast |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
300 V |
125 V |
400 A |
Tab/Blade |
200 kA |
Rated Breaking Capacity at 125 VDC: 20000 A |
1.311 in (33.3 mm) |
1.311 x 0.827 in (33.3 x 21 mm) |
2.752 in (69.9 mm) |
CE; CSA; CUL; UL |
Fast |
|||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
5.5 KV |
400 A |
End Cap |
80 kA |
10 m |
6.382 in (162.1 mm) |
Striker |
6.38 x 17.875 in (162.05 x 454.03 mm) |
17.875 in (454.03 mm) |
Medium |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
400 A |
Tab/Blade |
200 kA |
Bulk |
2.38 in (60.452 mm) |
8.63 in (219.202 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Threaded |
16.209 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Threaded |
16.209 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Threaded |
14.77 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.969 in (50 mm) |
Indicator |
3.402 in (86.4 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Threaded |
14.77 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.969 in (50 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Threaded |
11.104 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
2.008 in (51 mm) |
Indicator |
3.736 in (94.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Threaded |
11.104 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
2.008 in (51 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Threaded |
43.211 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Threaded |
43.211 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.913 in (74 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Threaded |
27.112 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Threaded |
27.112 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Threaded |
19.797 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.894 in (73.5 mm) |
Indicator |
4.268 in (108.4 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Threaded |
19.797 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.953 in (75 mm) |
2.894 in (73.5 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
400 A |
Tab/Blade |
116.271 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
400 A |
Threaded |
116.271 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
400 A |
Tab/Blade |
116.271 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Tab/Blade |
11.104 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Tab/Blade |
43.211 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Tab/Blade |
16.209 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Tab/Blade |
14.77 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.028 in (51.5 mm) |
1.937 in (49.2 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.2 KV |
900 V |
400 A |
Tab/Blade |
37.103 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 900 VDC: 150000 A |
Bulk |
2.823 in (71.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Tab/Blade |
27.112 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
400 A |
Tab/Blade |
19.797 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.921 in (74.2 mm) |
2.894 in (73.5 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Tab/Blade |
16.209 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
400 A |
Tab/Blade |
11.104 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.