600 A Fuses 9

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LA100P600-4TI

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

600 A

Tab/Blade

650 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

2.5 in (63.5 mm)

Indicator

2.5 x 3.469 in (63.5 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

LA100P600-4

Littelfuse

Electric Fuse

Inline/Holder

1 KV

750 V

600 A

Tab/Blade

650 J

100 kA

Rated Breaking Capacity at 750 VDC: 100000 A

2.5 in (63.5 mm)

2.5 x 3.469 in (63.5 x 88.1 mm)

3.469 in (88.1 mm)

UL

Very Fast

LA15QS600-4

Littelfuse

Electric Fuse

Inline/Holder

150 V

150 V

600 A

Tab/Blade

130 J

100 kA

Rated Breaking Capacity at 150 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 1.252 in (38.1 x 31.8 mm)

1.252 in (31.8 mm)

UL

Very Fast

LA30QS600-4TI

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

600 A

Tab/Blade

230 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

Indicator

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

LA30QS600-4

Littelfuse

Electric Fuse

Inline/Holder

300 V

300 V

600 A

Tab/Blade

230 J

200 kA

Rated Breaking Capacity at 300 VDC: 20000 A

1.5 in (38.1 mm)

1.5 x 1.579 in (38.1 x 40.1 mm)

1.579 in (40.1 mm)

UL

Very Fast

LA50QS600-4

Littelfuse

Electric Fuse

Inline/Holder

500 V

500 V

600 A

Tab/Blade

220 J

200 kA

Rated Breaking Capacity at 500 VDC: 100000 A

2 in (50.8 mm)

500 V

2 x 2.22 in (50.8 x 56.4 mm)

2.22 in (56.4 mm)

CSA; UL

Fast

LA70QS600-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

222 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS600-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

222 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

PV-600A-3L

Eaton Corporation

Electric Fuse

Inline/Holder

1 KV

600 A

Tab/Blade

137 kJ

50 kA

Bulk

5 in (127 mm)

2.953 in (75 mm)

2.953 in (75 mm)

IEC; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.