63 mA Fuses 18

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

20100630001P

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

11 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20100630021P

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

11 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20100630301P

Littelfuse

Electric Fuse

Inline/Holder

250 V

63 mA

End Cap

11 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Bulk

0.205 in (5.2 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20100630431P

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

11 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Tape And Reel

0.232 in (5.9 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.827 in (21 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

20100630531P

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

11 mJ

-25 °C (-13 °F)

80 A

5 ms

Pre Arcing Time: Open within 5 ms at 1000% Rated Current

Tape And Reel

0.232 in (5.9 mm)

0.197 x 0.787 in (5 x 20 mm)

Indicator

0.205 x 0.787 in (5.2 x 20 mm)

0.827 in (21 mm)

CUL; UL

70 °C (158 °F)

Medium Time Lag

39600630440

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 mA

Pin Wire

9 mJ

-40 °C (-40 °F)

Tin

100 A

1 m

0.009

Bulk

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

125 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.315 in (8 mm)

UL

85 °C (185 °F)

Time Lag

37000630410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

500 μJ

-40 °C (-40 °F)

Matte Tin

35 A

20 ms

Ammo Pack; Tape

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; VDE; UL

85 °C (185 °F)

Fast

37400630000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

15 mJ

-40 °C (-40 °F)

Tin

50 A

1 m

Ammo Pack

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA, UL

85 °C (185 °F)

Time Lag

37400630430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

15 mJ

-40 °C (-40 °F)

Tin

50 A

1 m

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA, UL

85 °C (185 °F)

Time Lag

37300630000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

200 μJ

-40 °C (-40 °F)

Tin

50 A

5 s

Ammo Pack; Tape

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA; CUL; UL

85 °C (185 °F)

Very Fast

37300630410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

200 μJ

-40 °C (-40 °F)

Tin

50 A

5 s

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA; CUL; UL

85 °C (185 °F)

Very Fast

37300630430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

200 μJ

-40 °C (-40 °F)

Tin

50 A

5 s

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CSA; CUL; UL

85 °C (185 °F)

Very Fast

39500630000

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 mA

Pin Wire

130 μJ

-40 °C (-40 °F)

Tin

100 A

1 m

Ammo Pack; Tape And Reel

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

125 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.315 in (8 mm)

UL

85 °C (185 °F)

Fast

39500630440

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 mA

Pin Wire

130 μJ

-40 °C (-40 °F)

Tin

100 A

1 m

Bulk

0.335 in (8.5 mm)

0.157 in (4 mm)

e3

125 V

TE5

0.335 x 0.157 x 0.315 in (8.5 x 4 x 8 mm)

0.315 in (8 mm)

UL

85 °C (185 °F)

Fast

30300630001

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 V

63 mA

Pin Wire

130 μJ

-25 °C (-13 °F)

50 A

1 m

Pre Arcing Time: Open within 60 s at 200% Rated Current

Ammo Pack; Tape

0.236 in (6 mm)

0.315 in (8 mm)

CSA; UL

70 °C (158 °F)

Fast

30300630131

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 V

63 mA

Pin Wire

130 μJ

-25 °C (-13 °F)

50 A

1 m

Pre Arcing Time: Open within 60 s at 200% Rated Current

Bulk

0.236 in (6 mm)

0.315 in (8 mm)

CSA; UL

70 °C (158 °F)

Fast

30300630421

Littelfuse

Electric Fuse

Through Hole Mount

125 V

63 V

63 mA

Pin Wire

130 μJ

-25 °C (-13 °F)

50 A

1 m

Pre Arcing Time: Open within 60 s at 200% Rated Current

Bulk

0.236 in (6 mm)

0.315 in (8 mm)

CSA; UL

70 °C (158 °F)

Fast

37000630430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

63 mA

Pin Wire

500 μJ

-40 °C (-40 °F)

Tin

35 A

20 ms

Ammo Pack; Tape

0.335 in (8.5 mm)

e3

TR5

0.315 in (8 mm)

CCC; CE; CUL; VDE; UL

85 °C (185 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.