| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
4 A |
Pin Wire |
544.5 mJ |
-65 °C (-85 °F) |
Tin |
200 A |
10 s |
Pre Arcing Time: Open within 10 s at 200% Rated Current |
0.54 |
Ammo Pack; Tape |
0.35 in (8.9 mm) |
0.183 in (4.65 mm) |
e3 |
250 V |
TE5 |
0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm) |
0.348 in (8.85 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Fast |
||||||
|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
4 A |
Pin Wire |
544.5 mJ |
-65 °C (-85 °F) |
Tin |
200 A |
10 s |
Pre Arcing Time: Open within 10 s at 200% Rated Current |
0.54 |
Bulk |
0.35 in (8.9 mm) |
0.183 in (4.65 mm) |
e3 |
250 V |
TE5 |
0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm) |
0.348 in (8.85 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Fast |
||||||
|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
4 A |
Pin Wire |
544.5 mJ |
-65 °C (-85 °F) |
Tin |
200 A |
10 s |
Pre Arcing Time: Open within 10 s at 200% Rated Current |
0.54 |
Bulk |
0.35 in (8.9 mm) |
0.183 in (4.65 mm) |
e3 |
250 V |
TE5 |
0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm) |
0.348 in (8.85 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Fast |
||||||
|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
5 A |
Pin Wire |
1.158 J |
-65 °C (-85 °F) |
Tin |
200 A |
10 s |
Pre Arcing Time: Open within 10 s at 200% Rated Current |
1.15 |
Bulk |
0.35 in (8.9 mm) |
0.183 in (4.65 mm) |
e3 |
250 V |
TE5 |
0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm) |
0.348 in (8.85 mm) |
CUL; PSE; UL |
125 °C (257 °F) |
Fast |
||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
6 A |
End Cap |
Nickel |
593 |
|||||||||||||||||||||||
|
Cooper Industries |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
110 A |
Tab/Blade |
300 kA |
LPN-RK |
Rated Breaking Capacity at 250 VDC: 100000 A |
Box |
1.61 in (40.89 mm) |
Indicator |
1.61 x 7.13 in (40.89 x 181.1 mm) |
7.13 in (181.1 mm) |
CSA; UL |
Time Delay |
|||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
380 V |
250 V |
16 A |
End Cap |
50 kA |
D0Z1 |
Rated Breaking Capacity at 250 VDC: 50000 A |
0.433 in (11 mm) |
Indicator |
0.433 x 1.417 in (11 x 36 mm) |
1.417 in (36 mm) |
DIN; IEC; VDE |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
380 V |
250 V |
4 A |
End Cap |
50 kA |
D0Z1 |
Rated Breaking Capacity at 250 VDC: 50000 A |
0.433 in (11 mm) |
Indicator |
0.433 x 1.417 in (11 x 36 mm) |
1.417 in (36 mm) |
DIN; IEC; VDE |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
380 V |
250 V |
6 A |
End Cap |
50 kA |
D0Z1 |
Rated Breaking Capacity at 250 VDC: 50000 A |
0.433 in (11 mm) |
Indicator |
0.433 x 1.417 in (11 x 36 mm) |
1.417 in (36 mm) |
DIN; IEC; VDE |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
380 V |
250 V |
63 A |
End Cap |
50 kA |
D0Z1 |
Rated Breaking Capacity at 250 VDC: 50000 A |
0.591 in (15 mm) |
Indicator |
0.591 x 1.417 in (15 x 36 mm) |
1.417 in (36 mm) |
DIN; IEC; VDE |
Fast |
||||||||||||||||
|
Littelfuse |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
2 A |
End Cap |
5.2 J |
Tin Lead |
35 A |
5 s |
Pre Arcing Time: Open within 5 s at 200% Rated Current |
5.2 |
0.25 in (6.35 mm) |
e0 |
250 V |
3AG |
0.25 x 1.25 in (6.35 x 31.75 mm) |
1.25 in (31.75 mm) |
CSA; UL |
Fast |
|||||||||||
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
5 A |
Pin Wire |
28.2 J |
1.5 kA |
28.2 |
0.207 in (5.25 mm) |
250 V |
0.197 x 0.787 in (5 x 20 mm) |
0.207 x 0.886 in (5.25 x 22.5 mm) |
0.886 in (22.5 mm) |
BSI; CCC; CSA; IEC; KTL; SEMKO; SEV; UL; VDE |
Fast |
|||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
1.25 A |
Wraparound |
5.2 J |
-40 °C (-40 °F) |
Tin |
150 A |
10 ms |
5.2 |
Tape And Reel |
0.413 in (10.5 mm) |
0.177 in (4.5 mm) |
e3 |
250 V |
Nano |
0.177 x 0.177 x 0.413 in (4.5 x 4.5 x 10.5 mm) |
0.177 in (4.5 mm) |
CUL; PSE; UL |
85 °C (185 °F) |
Time Lag |
|||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
250 V |
250 V |
2.5 A |
Wraparound |
8 J |
-40 °C (-40 °F) |
Matte Tin |
150 A |
10 ms |
8 |
Tape And Reel |
0.413 in (10.5 mm) |
0.177 in (4.5 mm) |
e3 |
250 V |
Nano |
0.177 x 0.177 x 0.413 in (4.5 x 4.5 x 10.5 mm) |
0.177 in (4.5 mm) |
CUL; PSE; UL |
85 °C (185 °F) |
Time Lag |
|||||||
|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
250 V |
250 V |
Pin Wire |
-40 °C (-40 °F) |
Bulk |
0.394 in (10 mm) |
TR5 |
0.394 in (10 mm) |
UL; VDE |
85 °C (185 °F) |
||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
400 A |
Tab/Blade |
200 kA |
Bulk |
2.38 in (60.452 mm) |
8.63 in (219.202 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
250 V |
450 A |
Tab/Blade |
200 kA |
Bulk |
2.88 in (73.152 mm) |
10.38 in (263.652 mm) |
CE; CSA; UL |
Time Delay |
|||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
Inline/Holder |
250 V |
15 A |
End Cap |
0.8 in (20.32 mm) |
2.97 in (75.43 mm) |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.