32 V Fuses 24

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK/ATC-35

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

35 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

32 V

0.752 x 0.201 x 0.483 in (19.1 x 5.1 x 12.28 mm)

0.483 in (12.28 mm)

UL

100 °C (212 °F)

Fast

MFU0402FF02000E100

Vishay Intertechnology

Electric Fuse

Surface Mount

32 V

2 A

Wraparound

10.1 mJ

15 °C (59 °F)

Matte Tin with Nickel barrier

50 A

Tape And Reel

0.039 in (1 mm)

0.02 in (0.5 mm)

e3

0.039 x 0.02 x 0.013 in (1 x 0.5 x 0.32 mm)

0.013 in (0.32 mm)

UL; UMF

35 °C (95 °F)

Very Fast

ERBRD0R50X

Panasonic

Electric Fuse

Surface Mount

32 V

500 mA

Wraparound

-40 °C (-40 °F)

35 A

Tape And Reel, Pressed, 7 inch

0.039 in (1 mm)

0.02 in (0.5 mm)

200 ms

0402

0.015 in (0.39 mm)

CUL, UL

125 °C (257 °F)

Fast

F0402E0R50FSTR

KYOCERA AVX

Electric Fuse

Surface Mount

32 V

32 V

500 mA

Wraparound

300 μJ

-55 °C (-67 °F)

Tin with Nickel barrier

50 A

Tape And Reel, 7 inch

0.039 in (1 mm)

0.022 in (0.55 mm)

e3

0402

0.039 x 0.022 x 0.016 in (1 x 0.55 x 0.4 mm)

0.016 in (0.4 mm)

125 °C (257 °F)

Fast

498150

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

-40 °C (-40 °F)

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

10-1001

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

-40 °C (-40 °F)

1 kA

80 ms

Pre Arcing Time: Open within 80 ms at 350% Rated Current

Blister

0.76 in (19.3 mm)

0.207 in (5.25 mm)

ATO

32 V

Indicator

0.48 in (12.2 mm)

125 °C (257 °F)

GBC25

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

25 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

GBC8

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

8 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

GBC5

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

5 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

GBC16

Littelfuse

Electric Fuse

Inline/Holder

32 V

32 V

16 A

0.236 in (6 mm)

32 V

0.236 x 0.984 in (6 x 25 mm)

0.984 in (25 mm)

FCD121315TP

Littelfuse

Electric Fuse

Surface Mount

32 V

3.15 A

Wraparound

280 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

FCD121400TP

Littelfuse

Electric Fuse

Surface Mount

32 V

4 A

Wraparound

500 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

FCD121500TP

Littelfuse

Electric Fuse

Surface Mount

32 V

5 A

Wraparound

970 mJ

-55 °C (-67 °F)

Tin

50 A

FCD12

Tape And Reel

0.126 in (3.2 mm)

0.063 in (1.6 mm)

e3

0.126 x 0.063 x 0.024 in (3.2 x 1.6 x 0.6 mm)

0.024 in (0.6 mm)

IEC; UL

125 °C (257 °F)

Fast

SF-0402S160-2

Bourns

Electric Fuse

Surface Mount

32 V

1.6 A

Wraparound

37.34 mJ

-20 °C (-4 °F)

Tin Over Nickel

35 A

5 s

Tape And Reel, 7 inch

0.039 in (1 mm)

0.02 in (0.52 mm)

e3

0402

0.039 x 0.02 x 0.014 in (1 x 0.52 x 0.35 mm)

0.014 in (0.35 mm)

UL

105 °C (221 °F)

Slow

431005

Littelfuse

Electric Fuse

Surface Mount

32 V

32 V

5 A

Wraparound

1.6 J

-55 °C (-67 °F)

Tin Lead Over Nickel

35 A

431

Rated Breaking Capacity at 32 VDC: 35 A

0.063 in (1.6 mm)

0.031 in (0.79 mm)

e0

0.063 x 0.031 x 0.018 in (1.6 x 0.79 x 0.46 mm)

0.018 in (0.46 mm)

CSA; UL

90 °C (194 °F)

Very Fast

05980016Z-CN

Littelfuse

Electric Fuse

Panel Mount

32 V

125 A

Screw

-40 °C (-40 °F)

125 °C (257 °F)

05980017Z-CN

Littelfuse

Electric Fuse

Panel Mount

32 V

200 A

Screw

-40 °C (-40 °F)

125 °C (257 °F)

05980019Z

Littelfuse

Electric Fuse

Panel Mount

32 V

Screw

-40 °C (-40 °F)

125 °C (257 °F)

05980020Z

Littelfuse

Electric Fuse

Panel Mount

32 V

Screw

-40 °C (-40 °F)

125 °C (257 °F)

10-1004

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

-40 °C (-40 °F)

1 kA

80 ms

Pre Arcing Time: Open within 80 ms at 350% Rated Current

Blister

0.76 in (19.3 mm)

0.207 in (5.25 mm)

Indicator

0.48 in (12.2 mm)

125 °C (257 °F)

05980015Z-CN

Littelfuse

Electric Fuse

Panel Mount

32 V

200 A

Screw

-40 °C (-40 °F)

125 °C (257 °F)

BK/MDA-30A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 V

30 A

End Cap

1.097 kJ

1.5 kA

Response Time: 120 s MAX at 200% Rated Current, Interrupting Current-Max(DC): 10000 A

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

Time Delay

BK/MDL-2-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 V

2.5 A

End Cap

100 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

Time Delay

SF-0603SP250-2

Bourns

Electric Fuse

Surface Mount

32 V

2.5 A

Wraparound

229 mJ

-20 °C (-4 °F)

Tin Over Nickel

50 A

1 s

Tape And Reel, 7 inch

0.063 in (1.6 mm)

0.031 in (0.8 mm)

e3

0603

0.018 in (0.45 mm)

UL

105 °C (221 °F)

Time Lag

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.