End Cap Fuses 430

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

02200010MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

550 mA

End Cap

2.04 J

-55 °C (-67 °F)

Tin

35 A

1 m 30 s

Rated Breaking Capacity at 125 VDC: 10000 A

1.16

Bulk

0.189 in (4.8 mm)

Supplemental

e3

250 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; UL

125 °C (257 °F)

02200019MXP

Littelfuse

Electric Fuse

Inline/Holder

350 V

125 V

3 A

End Cap

4.62 J

-55 °C (-67 °F)

Tin

100 A

1 s

4.62

Bulk

0.189 in (4.8 mm)

Supplemental

e3

350 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; CSA; PSE; UL

125 °C (257 °F)

02200030MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 V

375 mA

End Cap

820 mJ

-55 °C (-67 °F)

Tin

35 A

3 s

Rated Breaking Capacity at 125 VDC: 10000 A

0.58

Bulk

0.189 in (4.8 mm)

Supplemental

e3

250 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE; UL

125 °C (257 °F)

02200038MXP

Littelfuse

Electric Fuse

Inline/Holder

250 V

5 A

End Cap

267 J

-55 °C (-67 °F)

Tin

50 A

3 s

267

Bulk

0.189 in (4.8 mm)

Supplemental

e3

250 V

2AG

0.177 x 0.57 in (4.5 x 14.48 mm)

0.587 in (14.9 mm)

CE

125 °C (257 °F)

288001

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

2.22 J

35 A

288

0.177 in (4.5 mm)

0.177 x 0.57 in (4.5 x 14.48 mm)

0.57 in (14.48 mm)

CSA; METI; MIL; PSE; UL

Fast

215012

Littelfuse

Electric Fuse

Inline/Holder

250 V

12 A

End Cap

515 J

-55 °C (-67 °F)

Nickel

1.5 kA

Bulk; Tape And Reel

0.205 in (5.2 mm)

0.205 x 0.787 in (5.2 x 20 mm)

0.787 in (20 mm)

CE; CSA; IEC; KTL; PSE; UL

125 °C (257 °F)

Time Lag

4192150000

Littelfuse

Electric Fuse

Surface Mount

65 V

65 V

15 A

End Cap

103 J

-65 °C (-85 °F)

Silver

50 A

Tape And Reel

0.24 in (6.1 mm)

0.109 in (2.77 mm)

e4

30 s

0.24 x 0.109 x 0.109 in (6.1 x 2.77 x 2.77 mm)

0.109 in (2.77 mm)

CSA; UL

125 °C (257 °F)

Very Fast

LVSP0005TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

End Cap

359 J

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

LVSP0010TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

End Cap

1.3 kJ

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

LVSP0015TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

End Cap

3.267 kJ

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

LVSP0020TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

End Cap

4.94 kJ

200 kA

0.41 in (10.41 mm)

1.5 in (38.1 mm)

UL

LVSP0030TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

30 A

End Cap

11.95 kJ

200 kA

0.812 in (20.62 mm)

2.25 in (57.15 mm)

UL

LVSP0040TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

40 A

End Cap

20.55 kJ

200 kA

0.812 in (20.62 mm)

2.25 in (57.15 mm)

UL

LVSP0060TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

60 A

End Cap

39.24 kJ

200 kA

0.812 in (20.62 mm)

2.25 in (57.15 mm)

UL

LVSP0080TX2

Littelfuse

Electric Fuse

Inline/Holder

600 V

80 A

End Cap

75 kJ

200 kA

0.812 in (20.62 mm)

2.25 in (57.15 mm)

UL

3AB125-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

4 mJ

-55 °C (-67 °F)

Matte Tin

35 A

Pre-Arcing Time: Open within 5 s, at 200% Rated Current

Bulk; Tape And Reel

0.25 in (6.35 mm)

e3

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CE; CSA; UL

125 °C (257 °F)

Fast

3AB500-R

Bel Fuse

Electric Fuse

Inline/Holder

250 V

500 mA

End Cap

100 mJ

-55 °C (-67 °F)

Nickel

35 A

Bulk

0.25 in (6.35 mm)

250 V

0.236 x 1.26 in (6 x 32 mm)

0.25 x 1.252 in (6.35 x 31.8 mm)

1.252 in (31.8 mm)

CSA; CUL; UL

125 °C (257 °F)

Fast

F09A250V3A

Littelfuse

Electric Fuse

Inline/Holder

250 V

3 A

End Cap

35 A

0.415 in (10.54 mm)

0.415 x 1.531 in (10.54 x 38.89 mm)

1.531 in (38.89 mm)

MIL-PRF-15160/9

BK/MDA-30A

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 V

30 A

End Cap

1.097 kJ

1.5 kA

Response Time: 120 s MAX at 200% Rated Current, Interrupting Current-Max(DC): 10000 A

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

Time Delay

BK/MDL-2-1/2

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

32 V

2.5 A

End Cap

100 A

Pre Arcing Time: Open within 5 s at 200% Rated Current

Bulk

0.25 in (6.35 mm)

0.25 x 1.25 in (6.35 x 31.75 mm)

1.25 in (31.75 mm)

CE

Time Delay

35421000029

Littelfuse

Electric Fuse

Inline/Holder

440 V

10 A

End Cap

500 J

-25 °C (-13 °F)

Nickel

1 kA

Bulk

0.248 in (6.3 mm)

20 ms

0.248 x 1.26 in (6.3 x 32 mm)

1.26 in (32 mm)

CUL; UL

70 °C (158 °F)

Very Fast

0ADEC9100-BE

Bel Fuse

Electric Fuse

Inline/Holder

500 V

500 V

10 A

End Cap

100 J

-55 °C (-67 °F)

Silver

30 kA

10 s

Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current

Bulk

0.252 in (6.4 mm)

e4

500 V

0.236 x 1.26 in (6 x 32 mm)

1.252 in (31.8 mm)

CUL; UL

105 °C (221 °F)

Fast

24101250021

Littelfuse

Electric Fuse

Inline/Holder

250 V

125 mA

End Cap

53 mJ

-25 °C (-13 °F)

80 A

Bulk

0.205 in (5.2 mm)

5 ms

0.197 x 0.984 in (5 x 25 mm)

Indicator

0.984 in (25 mm)

70 °C (158 °F)

Medium Time Lag

24111000021

Littelfuse

Electric Fuse

Inline/Holder

250 V

1 A

End Cap

4.5 J

-25 °C (-13 °F)

80 A

Bulk

0.205 in (5.2 mm)

5 ms

0.197 x 0.984 in (5 x 25 mm)

Indicator

0.984 in (25 mm)

70 °C (158 °F)

Medium Time Lag

35606300029

Littelfuse

Electric Fuse

Inline/Holder

440 V

630 mA

End Cap

2 J

-25 °C (-13 °F)

1 kA

10 ms

Pre Arcing Time: Open within 0.01 s at 1000% Rated Current

Bulk

0.25 in (6.35 mm)

3AB

1.25 in (31.75 mm)

CE

70 °C (158 °F)

Slow

PF-EC1-15

Bourns

Electric Fuse

Inline/Holder

1 KV

15 A

End Cap

365 J

-55 °C (-67 °F)

20 kA

4 m

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PF-EC1-25

Bourns

Electric Fuse

Inline/Holder

1 KV

25 A

End Cap

1.202 kJ

-55 °C (-67 °F)

20 kA

4 m

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PF-EC1-30

Bourns

Electric Fuse

Inline/Holder

1 KV

30 A

End Cap

2.229 kJ

-55 °C (-67 °F)

20 kA

4 m

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PF-HC1-20

Bourns

Electric Fuse

Inline/Holder

600 V

600 V

20 A

End Cap

206.48 J

-55 °C (-67 °F)

150 kA

4 m

Rated Breaking Capacity at 600 VDC: 10000 A

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; TUV; UL

125 °C (257 °F)

PF-EC1-20

Bourns

Electric Fuse

Inline/Holder

1 KV

20 A

End Cap

804.3 J

-55 °C (-67 °F)

20 kA

4 m

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; UL

125 °C (257 °F)

PF-HC1-15

Bourns

Electric Fuse

Inline/Holder

600 V

600 V

15 A

End Cap

51.64 J

-55 °C (-67 °F)

150 kA

4 m

Rated Breaking Capacity at 600 VDC: 10000 A

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; TUV; UL

125 °C (257 °F)

PF-HC1-25

Bourns

Electric Fuse

Inline/Holder

600 V

600 V

25 A

End Cap

1.607 kJ

-55 °C (-67 °F)

150 kA

4 m

Rated Breaking Capacity at 600 VDC: 10000 A

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; TUV; UL

125 °C (257 °F)

PF-HC1-30

Bourns

Electric Fuse

Inline/Holder

600 V

600 V

30 A

End Cap

1.74 kJ

-55 °C (-67 °F)

150 kA

4 m

Rated Breaking Capacity at 600 VDC: 10000 A

Bulk

0.406 in (10.3 mm)

5AG

1.496 in (38 mm)

CUL; TUV; UL

125 °C (257 °F)

63D33R

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

63 A

End Cap

26.5 kJ

50 kA

Bulk

1.063 in (27 mm)

DIII

1.969 in (50 mm)

DIN 49515; IEC60269

Ultra Fast

XEV10-50

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

50 A

End Cap

2.74 kJ

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

XEV10-40

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

40 A

End Cap

1.72 kJ

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

XEV10-30

Eaton Corporation

Electric Fuse

Inline/Holder

500 V

30 A

End Cap

1.15 kJ

-40 °C (-40 °F)

20 kA

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.5 in (38.1 mm)

125 °C (257 °F)

15CLE-175E

Eaton Corporation

Electric Fuse

Inline/Holder

14.4 KV

14.4 KV

175 A

End Cap

63 kA

2.992 in (76 mm)

23.898 in (607 mm)

15CLPT-5E

Eaton Corporation

Electric Fuse

Inline/Holder

14.4 KV

14.4 KV

3 A

End Cap

80 kA

1.614 in (41 mm)

17.598 in (447 mm)

15NCLPT-2E

Eaton Corporation

Electric Fuse

Inline/Holder

14.4 KV

14.4 KV

2 A

End Cap

63 kA

1.614 in (41 mm)

12.913 in (328 mm)

15SRC250

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

15 A

End Cap

0.8 in (20.32 mm)

2.97 in (75.43 mm)

15CLE-25E-D

Eaton Corporation

Electric Fuse

Inline/Holder

15.5 KV

15.5 KV

25 A

End Cap

63 kA

2.992 in (76 mm)

23.898 in (607 mm)

ANSI

15CLE-65E

Eaton Corporation

Electric Fuse

Inline/Holder

15.5 KV

15.5 KV

65 A

End Cap

63 kA

2.992 in (76 mm)

23.898 in (607 mm)

ANSI; UL

15CLE-20E-D

Eaton Corporation

Electric Fuse

Inline/Holder

15.5 KV

15.5 KV

20 A

End Cap

63 kA

2.992 in (76 mm)

23.898 in (607 mm)

ANSI

FWP-50G22FI

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

500 V

50 A

End Cap

273 J

200 kA

Bulk

0.866 in (22 mm)

0.866 x 2.283 in (22 x 58 mm)

Indicator

2.283 in (58 mm)

IEC; UL

FWP-20G10F

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

500 V

20 A

End Cap

23.5 J

200 kA

Rated Breaking Capacity at 500 VDC: 50000 A

Bulk

0.406 in (10.3 mm)

0.394 x 1.496 in (10 x 38 mm)

1.496 in (38 mm)

IEC; UL

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.