Tab/Blade Fuses 810

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

BK/ATC-35

Eaton Corporation

Electric Fuse

Inline/Holder

32 V

32 V

35 A

Tab/Blade

-40 °C (-40 °F)

Tin

1 kA

100 ms

Bulk

0.752 in (19.1 mm)

0.201 in (5.1 mm)

e3

32 V

0.752 x 0.201 x 0.483 in (19.1 x 5.1 x 12.28 mm)

0.483 in (12.28 mm)

UL

100 °C (212 °F)

Fast

BP/ATM-10-RP

Eaton Corporation

Electric Fuse

10 A

Tab/Blade

-40 °C (-40 °F)

Silver

1 kA

0.43 in (10.92 mm)

0.15 in (3.81 mm)

e4

32 V

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

UL

100 °C (212 °F)

Fast

BP/ATM-15-RP

Eaton Corporation

Electric Fuse

15 A

Tab/Blade

-40 °C (-40 °F)

Silver

1 kA

0.43 in (10.92 mm)

0.15 in (3.81 mm)

e4

32 V

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

UL

100 °C (212 °F)

Fast

NH00CM100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM10

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

10 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM16

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

16 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM20

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

20 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM35

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

35 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM40

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

40 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM4

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

4 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM50

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

50 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM63

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

63 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM6

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

6 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CM80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

400NH2GL

Altech

Electric Fuse

Inline/Holder

500 V

400 A

Tab/Blade

Bulk

2.559 in (65 mm)

2.087 in (53 mm)

2.362 in (60 mm)

Slow

NH00CG4

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

4 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CG50

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

50 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00G125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.126 in (56.4 x 30 x 54 mm)

2.126 in (54 mm)

VDE

NH0G25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH1CG160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH1CG32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH1CG63

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

63 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

LPN-RK-110SPI

Cooper Industries

Electric Fuse

Inline/Holder

250 V

250 V

110 A

Tab/Blade

300 kA

LPN-RK

Rated Breaking Capacity at 250 VDC: 100000 A

Box

1.61 in (40.89 mm)

Indicator

1.61 x 7.13 in (40.89 x 181.1 mm)

7.13 in (181.1 mm)

CSA; UL

Time Delay

KLC10

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC15

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC1

Littelfuse

Electric Fuse

Inline/Holder

600 V

1 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC20

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC2

Littelfuse

Electric Fuse

Inline/Holder

600 V

2 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC30

Littelfuse

Electric Fuse

Inline/Holder

600 V

30 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC3

Littelfuse

Electric Fuse

Inline/Holder

600 V

3 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC4

Littelfuse

Electric Fuse

Inline/Holder

600 V

4 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC5

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

KLC60

Littelfuse

Electric Fuse

Inline/Holder

600 V

60 A

Tab/Blade

200 kA

0.811 in (20.6 mm)

0.811 x 2.752 in (20.6 x 69.9 mm)

2.752 in (69.9 mm)

CSA; UL

Fast

KLC6

Littelfuse

Electric Fuse

Inline/Holder

600 V

6 A

Tab/Blade

200 kA

0.563 in (14.3 mm)

0.563 x 1.874 in (14.3 x 47.6 mm)

1.874 in (47.6 mm)

CSA; UL

Fast

LA050URD32LI1800

Littelfuse

Electric Fuse

Inline/Holder

500 V

1.8 kA

Tab/Blade

1.05 kJ

200 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA050URD33LI2500

Littelfuse

Electric Fuse

Inline/Holder

500 V

2.5 kA

Tab/Blade

1.87 kJ

200 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA055URD32LI1400

Littelfuse

Electric Fuse

Inline/Holder

550 V

1.4 kA

Tab/Blade

555 J

200 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA055URD32LI1600

Littelfuse

Electric Fuse

Inline/Holder

550 V

1.6 kA

Tab/Blade

870 J

200 kA

2.362 in (60 mm)

2.362 in (60 mm)

Indicator

2.362 x 2.362 x 1.874 in (60 x 60 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA060URD32LI1250

Littelfuse

Electric Fuse

Inline/Holder

600 V

1.25 kA

Tab/Blade

410 J

200 kA

LA

Indicator

UL

Very Fast

LA060URD33LI2000

Littelfuse

Electric Fuse

Inline/Holder

600 V

2 kA

Tab/Blade

950 J

200 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA065URD32LI1100

Littelfuse

Electric Fuse

Inline/Holder

650 V

1.1 kA

Tab/Blade

270 J

200 kA

LA

Indicator

UL

Very Fast

LA065URD33LI1600

Littelfuse

Electric Fuse

Inline/Holder

650 V

1.6 kA

Tab/Blade

555 J

200 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA065URD33LI1800

Littelfuse

Electric Fuse

Inline/Holder

650 V

1.8 kA

Tab/Blade

720 J

200 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 1.874 in (74.5 x 74.5 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA065URD73LI1800

Littelfuse

Electric Fuse

Inline/Holder

660 V

1.8 kA

Tab/Blade

2.04 kJ

100 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

Indicator

2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

LA070URD30KI0063

Littelfuse

Electric Fuse

Inline/Holder

700 V

63 A

Tab/Blade

200 mJ

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

LA070URD30KI0080

Littelfuse

Electric Fuse

Inline/Holder

700 V

80 A

Tab/Blade

330 mJ

200 kA

1.575 in (40 mm)

1.575 in (40 mm)

Indicator

1.575 x 1.575 x 1.874 in (40 x 40 x 47.6 mm)

1.874 in (47.6 mm)

UL

Very Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.