Littelfuse Fuses 1,824

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

L17T1000V

Littelfuse

Electric Fuse

1 kA

100 kA

170 V

1.339 in (34 mm)

1.339 in (34 mm)

CE, CSA, UL

L17T1100V

Littelfuse

Electric Fuse

1.1 kA

100 kA

170 V

1.339 in (34 mm)

1.339 in (34 mm)

CE, CSA, UL

0603SFP600F/32-2

Littelfuse

Electric Fuse

60 A

4 J

-55 °C (-67 °F)

0.069 in (1.75 mm)

0.037 in (0.95 mm)

32 V

0603

0.069 x 0.037 x 0.037 in (1.75 x 0.95 x 0.95 mm)

0.037 in (0.95 mm)

125 °C (257 °F)

1206SFP250F/32-2

Littelfuse

Electric Fuse

25 A

1.19 J

-55 °C (-67 °F)

0.134 in (3.4 mm)

0.071 in (1.8 mm)

32 V

1206

0.134 x 0.071 x 0.046 in (3.4 x 1.8 x 1.17 mm)

0.046 in (1.17 mm)

125 °C (257 °F)

1206SFP600F/24-2

Littelfuse

Electric Fuse

60 A

12.5 J

-55 °C (-67 °F)

0.134 in (3.4 mm)

0.071 in (1.8 mm)

24 V

1206

0.134 x 0.071 x 0.046 in (3.4 x 1.8 x 1.17 mm)

0.046 in (1.17 mm)

125 °C (257 °F)

1206SFP700F/24-2

Littelfuse

Electric Fuse

70 A

30 J

-55 °C (-67 °F)

0.134 in (3.4 mm)

0.071 in (1.8 mm)

24 V

1206

0.134 x 0.071 x 0.046 in (3.4 x 1.8 x 1.17 mm)

0.046 in (1.17 mm)

125 °C (257 °F)

1206SFP800F/24-2

Littelfuse

Electric Fuse

80 A

60 J

-55 °C (-67 °F)

0.134 in (3.4 mm)

0.071 in (1.8 mm)

24 V

1206

0.134 x 0.071 x 0.046 in (3.4 x 1.8 x 1.17 mm)

0.046 in (1.17 mm)

125 °C (257 °F)

38211000410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

4.85 J

-40 °C (-40 °F)

Matte Tin

100 A

150 ms

3

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38211000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

4.85 J

-40 °C (-40 °F)

Tin

100 A

150 ms

3

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38211250410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.25 A

Wire

6.88 J

-40 °C (-40 °F)

Tin

100 A

150 ms

4.5

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38211250430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.25 A

Wire

6.88 J

-40 °C (-40 °F)

Tin

100 A

150 ms

4.5

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38211600430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.6 A

Wire

12.67 J

-40 °C (-40 °F)

Tin

100 A

150 ms

9

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38212000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Wire

17.8 J

-40 °C (-40 °F)

Tin

100 A

150 ms

12

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38212500410

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.5 A

Wire

29.69 J

-40 °C (-40 °F)

Tin

100 A

150 ms

22

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38212500430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.5 A

Wire

29.69 J

-40 °C (-40 °F)

Tin

100 A

150 ms

22

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38213150430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Wire

45.35 J

-40 °C (-40 °F)

Tin

100 A

150 ms

32

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38215000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Wire

121.25 J

-40 °C (-40 °F)

Tin

100 A

150 ms

90

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38216300430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.3 A

Wire

148.84 J

-40 °C (-40 °F)

Tin

100 A

150 ms

105

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CCC; CE; CUL; PSE; UL; VDE

85 °C (185 °F)

Time Lag

38218000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

8 A

Wire

233.6 J

-40 °C (-40 °F)

Tin

100 A

150 ms

180

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL

85 °C (185 °F)

Time Lag

38221000430

Littelfuse

Electric Fuse

Through Hole Mount

250 V

10 A

Wire

365 J

-40 °C (-40 °F)

Tin

100 A

150 ms

260

Bulk

0.335 in (8.5 mm)

e3

250 V

TR5

0.335 x 0.315 in (8.5 x 8 mm)

0.315 in (8 mm)

CUL; PSE; UL

85 °C (185 °F)

Time Lag

80408000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

800 mA

Wire

12.48 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

CQC; IEC; VDE

125 °C (257 °F)

Time Lag

80408000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

800 mA

Wire

12.48 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

CQC; IEC; VDE

125 °C (257 °F)

Time Lag

80411000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

20 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

CQC; IEC; VDE; PSE

125 °C (257 °F)

Time Lag

80411000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1 A

Wire

20 J

-40 °C (-40 °F)

Matte Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

CQC; IEC; VDE; PSE

125 °C (257 °F)

Time Lag

80411250000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.25 A

Wire

30 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80411250440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.25 A

Wire

30 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80411600000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.6 A

Wire

51 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80411600440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

1.6 A

Wire

51 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80412000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2 A

Wire

88 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80412500000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.5 A

Wire

137.5 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80412500440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

2.5 A

Wire

137.5 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80413150000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Wire

212.94 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80413150440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

3.15 A

Wire

212.94 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80414000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Wire

368 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80414000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

4 A

Wire

368 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80415000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Wire

748 J

-40 °C (-40 °F)

Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80415000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

5 A

Wire

748 J

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80416300000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.3 A

Wire

1.099 kJ

-40 °C (-40 °F)

Matte Tin

150 A

1 s

Ammo Pack

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

80416300440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

6.3 A

Wire

1.099 kJ

-40 °C (-40 °F)

Tin

150 A

1 s

Bulk

0.488 in (12.4 mm)

0.252 in (6.4 mm)

e3

250 V

TE7

0.488 x 0.252 x 0.386 in (12.4 x 6.4 x 9.8 mm)

0.362 in (9.2 mm)

125 °C (257 °F)

Time Lag

276001

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

1 A

Pin Wire

-55 °C (-67 °F)

50 A

276

Rated Breaking Capacity at 125 VDC: 300 A

0.093 in (2.36 mm)

0.093 x 0.28 in (2.36 x 7.11 mm)

0.28 in (7.11 mm)

CSA; UL

125 °C (257 °F)

Very Fast

276003

Littelfuse

Electric Fuse

Through Hole Mount

125 V

125 V

3 A

Pin Wire

-55 °C (-67 °F)

50 A

276

Rated Breaking Capacity at 125 VDC: 300 A

0.093 in (2.36 mm)

0.093 x 0.28 in (2.36 x 7.11 mm)

0.28 in (7.11 mm)

CSA; UL

125 °C (257 °F)

Very Fast

80811000000

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1 A

Pin Wire

6.6 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.0066

Ammo Pack; Tape And Reel

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80811000075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1 A

Pin Wire

6.6 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.0066

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80811000440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1 A

Pin Wire

6.6 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.0066

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80811600075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1.6 A

Pin Wire

34.4 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.03

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80811600440

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

1.6 A

Pin Wire

34.4 mJ

-40 °C (-40 °F)

Tin

100 A

4 h

Rated Breaking Capacity at 450 VDC: 10000 A

0.03

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

UL

125 °C (257 °F)

Fast

80812000075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

2 A

Pin Wire

61 mJ

-65 °C (-85 °F)

Matte Tin

200 A

10 s

Pre Arcing Time: Open within 10 s at 200% Rated Current

0.061

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

CUL; PSE; UL

125 °C (257 °F)

Fast

80812500075

Littelfuse

Electric Fuse

Through Hole Mount

250 V

450 V

2.5 A

Pin Wire

89.8 mJ

-65 °C (-85 °F)

Tin

200 A

10 s

Pre Arcing Time: Open within 10 s at 200% Rated Current

0.08

Bulk

0.35 in (8.9 mm)

0.183 in (4.65 mm)

e3

250 V

TE5

0.35 x 0.183 x 0.348 in (8.9 x 4.65 x 8.85 mm)

0.348 in (8.85 mm)

CUL; PSE; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.