| Part | RoHS | Manufacturer | Circuit Protection Type | Mounting Feature | Rated AC Voltage | Rated DC Voltage | Rated Current | Terminal Shape | Nominal Joule Integral | Minimum Operating Temperature | Terminal Finish | Rated Breaking Capacity | Manufacturer Series | Trip Time/Delay | Additional Features | Pre Arcing Rating (A2/s) | Packing Method | Body Length/Diameter | Body Width | Fuse Class | JESD-609 Code | Rated Voltage | Resistance | Minimum Pre Arcing Time | Fuse Size | Built-in Features | Dimensions | Body Height | Reference Standard | Maximum Operating Temperature | Blow Characteristic |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Littelfuse |
Electric Fuse |
Through Hole Mount |
125 V |
63 V |
2 A |
Pin Wire |
170 mJ |
-25 °C (-13 °F) |
50 A |
1 m |
Pre Arcing Time: Open within 60 s at 200% Rated Current |
Bulk |
0.236 in (6 mm) |
0.236 x 0.315 in (6 x 8 mm) |
0.315 in (8 mm) |
CSA; UL |
70 °C (158 °F) |
Fast |
||||||||||||
|
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
Eaton Corporation |
Electric Fuse |
||||||||||||||||||||||||||||||
|
|
Bourns |
Electric Fuse |
Surface Mount |
125 V |
1.5 A |
Wraparound |
500 mJ |
-55 °C (-67 °F) |
Tin Over Nickel |
100 A |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.098 in (2.5 mm) |
e3 |
5 s |
1210 |
0.126 x 0.098 x 0.063 in (3.2 x 2.5 x 1.6 mm) |
0.063 in (1.6 mm) |
UL |
125 °C (257 °F) |
Slow |
||||||||||
|
|
Bourns |
Electric Fuse |
Surface Mount |
63 V |
750 mA |
Wraparound |
5.1 mJ |
-55 °C (-67 °F) |
50 A |
50 ms |
Tape And Reel, 7 inch |
0.126 in (3.2 mm) |
0.063 in (1.6 mm) |
1 ms |
1206 |
0.126 x 0.063 x 0.038 in (3.2 x 1.6 x 0.97 mm) |
0.038 in (0.97 mm) |
UL |
125 °C (257 °F) |
Slow |
|||||||||||
|
|
Littelfuse |
Electric Fuse |
500 mA |
-55 °C (-67 °F) |
Tin/Nickel |
50 A |
4 h |
0.015 |
0.067 in (1.7 mm) |
0.036 in (0.91 mm) |
e2 |
65 V |
0603 |
0.067 x 0.036 x 0.016 in (1.7 x 0.91 x 0.4 mm) |
0.016 in (0.4 mm) |
90 °C (194 °F) |
Fast |
||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
40 A |
Threaded |
76 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.969 in (50 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CCC; CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Bourns |
Electric Fuse |
Surface Mount |
32 V |
2.5 A |
Wraparound |
229 mJ |
-20 °C (-4 °F) |
Tin Over Nickel |
50 A |
1 s |
Tape And Reel, 7 inch |
0.063 in (1.6 mm) |
0.031 in (0.8 mm) |
e3 |
0603 |
0.018 in (0.45 mm) |
UL |
105 °C (221 °F) |
Time Lag |
|||||||||||
|
|
Bel Fuse |
Electric Fuse |
Inline/Holder |
500 V |
500 V |
10 A |
End Cap |
100 J |
-55 °C (-67 °F) |
Silver |
30 kA |
10 s |
Interrupting Current Max(DC): 20000 A, Pre Arcing Time: Open within 10 s at 300% Rated Current |
Bulk |
0.252 in (6.4 mm) |
e4 |
500 V |
0.236 x 1.26 in (6 x 32 mm) |
1.252 in (31.8 mm) |
CUL; UL |
105 °C (221 °F) |
Fast |
|||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
62 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel |
0.213 in (5.4 mm) |
0.126 in (3.2 mm) |
0.071 in (1.8 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
45 A |
Wraparound |
-10 °C (14 °F) |
120 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
45 A |
Wraparound |
-10 °C (14 °F) |
120 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
45 A |
Wraparound |
-10 °C (14 °F) |
120 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
85 V |
30 A |
Wraparound |
-10 °C (14 °F) |
80 A |
Tape And Reel, 13 inch |
0.374 in (9.5 mm) |
0.197 in (5 mm) |
0.079 in (2 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
|||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Surface Mount |
36 V |
15 A |
Wraparound |
-10 °C (14 °F) |
50 A |
Tape And Reel, 13 inch |
0.157 in (4 mm) |
0.118 in (3 mm) |
36 V |
0.035 in (0.9 mm) |
CUL; TUV; UL |
65 °C (149 °F) |
||||||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.5 KV |
400 A |
Tab/Blade |
116.271 kJ |
-55 °C (-67 °F) |
250 kA |
Bulk |
4.988 in (126.7 mm) |
2.028 in (51.5 mm) |
Indicator |
2.028 in (51.5 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||||
|
|
Bel Fuse |
Electric Fuse |
Through Hole Mount |
600 V |
600 V |
10 A |
Pin Wire |
101.4 J |
-55 °C (-67 °F) |
10 kA |
2 m |
Bulk |
0.266 in (6.76 mm) |
600 V |
0.236 x 1.26 in (6 x 32 mm) |
1.291 in (32.8 mm) |
CUL; UL |
105 °C (221 °F) |
Fast |
||||||||||||
|
|
Schurter Ag |
Electric Fuse |
Surface Mount |
63 V |
125 V |
4 A |
Wraparound |
90 mJ |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 32 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
63 V |
5 s |
1206 |
0.061 in (1.55 mm) |
CUL, UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
|
Schurter Ag |
Electric Fuse |
Surface Mount |
125 V |
125 V |
1 A |
Wraparound |
4.8 mJ |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 125 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
125 V |
5 s |
1206 |
0.061 in (1.55 mm) |
CUL, UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
|
Schurter Ag |
Electric Fuse |
Surface Mount |
32 V |
125 V |
5 A |
Wraparound |
140 mJ |
-55 °C (-67 °F) |
50 A |
Rated Breaking Capacity at 32 VDC: 300 A |
Tape |
0.126 in (3.2 mm) |
0.061 in (1.55 mm) |
32 V |
5 s |
1206 |
0.061 in (1.55 mm) |
CUL, UL |
125 °C (257 °F) |
Very Fast |
||||||||||
|
|
Bel Fuse |
Electric Fuse |
Surface Mount |
250 V |
125 V |
2 A |
Wraparound |
1 J |
-55 °C (-67 °F) |
Palladium |
300 A |
1 m |
Rated Breaking Capacity at 125 VDC: 2000 A |
Tape And Reel, 13 inch |
0.386 in (9.8 mm) |
0.12 in (3.05 mm) |
e4 |
250 V |
3912 |
0.12 in (3.05 mm) |
AEC-Q200; CUL; CE; UL |
125 °C (257 °F) |
|||||||||
|
|
Bel Fuse |
Electric Fuse |
Surface Mount |
250 V |
125 V |
1.25 A |
Wraparound |
400 mJ |
-55 °C (-67 °F) |
Palladium |
300 A |
1 m |
Rated Breaking Capacity at 125 VDC: 2000 A |
Tape And Reel, 13 inch |
0.386 in (9.8 mm) |
0.12 in (3.05 mm) |
e4 |
250 V |
3912 |
0.12 in (3.05 mm) |
AEC-Q200; CUL; CE; UL |
125 °C (257 °F) |
|||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
900 A |
Tab/Blade |
107.785 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
550 A |
Tab/Blade |
26.327 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
630 A |
Tab/Blade |
34.79 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.362 in (60 mm) |
1.937 in (49.2 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
800 A |
Tab/Blade |
84.691 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
1.4 kA |
Tab/Blade |
583.552 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
650 V |
500 V |
1.5 kA |
Tab/Blade |
674.538 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
600 V |
480 V |
2 kA |
Tab/Blade |
1.234 MJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 480 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
1.25 kA |
Tab/Blade |
476.902 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
500 V |
1.4 kA |
Tab/Blade |
583.552 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
650 V |
500 V |
1.6 kA |
Tab/Blade |
779.948 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 500 VDC: 150000 A |
Bulk |
2.894 in (73.5 mm) |
1.976 in (50.2 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
250 A |
Tab/Blade |
8.629 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.823 in (71.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
200 A |
Tab/Blade |
4.918 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.028 in (51.5 mm) |
Indicator |
3.402 in (86.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
280 A |
Tab/Blade |
10.915 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
450 A |
Tab/Blade |
35.927 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
550 A |
Tab/Blade |
73.858 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.882 in (73.2 mm) |
2.362 in (60 mm) |
Indicator |
3.736 in (94.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
1.3 KV |
1 KV |
500 A |
Tab/Blade |
42.751 kJ |
-55 °C (-67 °F) |
100 kA |
Rated Breaking Capacity at 1000 VDC: 150000 A |
Bulk |
2.921 in (74.2 mm) |
2.894 in (73.5 mm) |
Indicator |
4.268 in (108.4 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
40 A |
Tab/Blade |
76 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
125 A |
Tab/Blade |
707 J |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
315 A |
Tab/Blade |
7.131 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
||||||||||||
|
|
Littelfuse |
Electric Fuse |
Inline/Holder |
700 V |
600 V |
450 A |
Tab/Blade |
23.133 kJ |
-55 °C (-67 °F) |
200 kA |
Rated Breaking Capacity at 600 VDC: 150000 A |
Bulk |
1.878 in (47.7 mm) |
1.693 in (43 mm) |
Indicator |
3.067 in (77.9 mm) |
CUL; UL |
125 °C (257 °F) |
Fast |
A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.
A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.
Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.
In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.