| Part | RoHS | Manufacturer | Connector Accessory Type | Connector Side-1 | Connector Side-2 | Rated Voltage | Rated Current | Shielding | Approvals (V) | Cross Section Area | Finish Thickness | Conductor Material | Construction | Minimum Wire Size | Jacket Material | Terminal Type | Resistance | Conductor Finish | MIL Conformity | Maximum Wire Size | Insulator Material | Maximum Operating Temperature | DIN Conformity | Application | Cable Types | IEC Conformity | Minimum Operating Temperature | Wire Gauge (AWG) | Design | Diameter | No. of Conductors | Mounting Style | Additional Features | Material | Mounting Option-2 | Length | Mounting Option-1 | Wire & Cable Name | Stranding | Rated DC Voltage |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
26 |
1.3 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
|||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
YES |
CE; CSA; UL |
.518 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYLCHLORIDE |
.033 ohm |
TIN |
NO |
POLYETHYLENE |
75 Cel |
NO |
NO |
-20 Cel |
20 |
4.93 mm |
2 |
30.48 mm |
COMMUNICATION AND CONTROL CABLE |
7X28 |
|||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
150 V |
NO |
.518 mm2 |
COPPER ALLOY |
STRANDED |
.031 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-55 Cel |
20 |
1.52 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
19X32 |
||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.518 mm2 |
COPPER ALLOY |
SOLID |
.034 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
20 |
1.63 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X20 |
||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
5000 V |
NO |
.823 mm2 |
COPPER ALLOY |
STRANDED |
.022 ohm |
TIN |
NO |
ETHYLENE PROPYLENE RUBBER |
90 Cel |
NO |
NO |
-30 Cel |
18 |
3.48 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
65X36 |
|||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; IEC; UL |
.82 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.829 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X18 |
||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
26 |
1.3 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.823 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.83 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X18 |
||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.518 mm2 |
COPPER ALLOY |
SOLID |
.034 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
20 |
1.63 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X20 |
||||||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.051 mm2 |
COPPER ALLOY |
STRANDED |
.331 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
30 |
1.12 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X38 |
||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; IEC; UL |
.82 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.829 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X18 |
||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
26 |
1.3 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
600 V |
NO |
CE; CSA; UL |
.823 mm2 |
COPPER ALLOY |
STRANDED |
.023 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
2.82 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
16X30 |
||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
300 V |
5 A |
YES |
CEC; CUL; NEC; UL |
.823 mm2 |
COPPER ALLOY |
STRANDED |
POLYVINYL CHLORIDE |
.021 ohm |
NO |
POLYPROPYLENE |
75 Cel |
NO |
INTERCOM/PA SYSTEMS AND SOUND/AUDIO SYSTEMS |
NO |
-20 Cel |
18 |
4.114 mm |
2 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
7X26 |
||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; IEC; UL |
.82 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.829 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X18 |
||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.823 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.829 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
300 V |
5 A |
NO |
CEC; CUL; NEC; UL |
.823 mm2 |
BARE COPPER |
STRANDED |
POLYVINYL CHLORIDE |
.021 ohm |
NO |
POLYVINYL CHLORIDE |
75 Cel |
NO |
INTERCOM/PA SYSTEMS AND SOUND/AUDIO SYSTEMS |
NO |
0 Cel |
18 |
3.911 mm |
2 |
304.8 mm |
COMMUNICATION AND CONTROL CABLE |
7X26 |
||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CE; CSA; IEC; UL |
.82 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.829 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X18 |
||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
Belden |
WIRE AND CABLE |
300 V |
3.75 A |
YES |
CPR; CEC; NEC; UL |
.518 mm2 |
BARE COPPER |
STRANDED |
POLYVINYLCHLORIDE |
.034 ohm |
NO |
POLYPROPYLENE |
75 Cel |
NO |
NO |
-20 Cel |
20 |
3.606 mm |
2 |
COMMUNICATION AND CONTROL CABLE |
7X28 |
||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
CSA; UL |
.823 mm2 |
COPPER ALLOY |
SOLID |
.022 ohm |
TIN |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-40 Cel |
18 |
1.83 mm |
1 |
30.48 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
1X18 |
||||||||||||||||||
|
|
TE Connectivity |
WIRE AND CABLE |
600 V |
COPPER ALLOY |
SILVER |
0 AWG |
200 Cel |
SPEC 55 |
-65 Cel |
0 |
FLEXIBLE CORD AND FIXTURE WIRE |
|||||||||||||||||||||||||||||
|
|
Harting Electronics & Kg |
CABLE ASSEMBLY |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
PVC |
105 Cel |
NO |
NO |
-20 Cel |
28 |
34 |
DIAMETER OF INDIVIDUAL CONDUCTOR IS 1.09 MM |
30.48 mm |
FLAT CABLE |
7X0.127 |
|||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
UL |
.081 mm2 |
COPPER ALLOY |
STRANDED |
TIN |
NO |
PVC |
105 Cel |
NO |
NO |
-20 Cel |
28 |
64 |
DIAMETER OF INDIVIDUAL CONDUCTOR IS 1.09 MM |
30.48 mm |
FLAT CABLE |
7X0.127 |
|||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
NO |
CUL; UL |
.129 mm2 |
TINNED COPPER |
STRANDED |
NO |
POLYVINYLCHLORIDE |
105 Cel |
NO |
NO |
-20 Cel |
26 |
20 |
30.48 mm |
FLAT CABLE |
7X34 |
|||||||||||||||||||||
|
|
Molex |
CABLE ASSEMBLY |
||||||||||||||||||||||||||||||||||||||
|
|
Molex |
CABLE ASSEMBLY |
||||||||||||||||||||||||||||||||||||||
|
|
Molex |
CABLE ASSEMBLY |
||||||||||||||||||||||||||||||||||||||
|
|
Molex |
CABLE ASSEMBLY |
||||||||||||||||||||||||||||||||||||||
|
|
Molex |
CABLE ASSEMBLY |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
300 V |
CUL; UL |
COPPER |
STRANDED |
TIN |
NO |
PVC |
105 Cel |
NO |
NO |
-20 Cel |
28 |
20 |
FLAT FLEXIBLE CABLE |
7X36 |
|||||||||||||||||||||||
|
|
3m Electronic Products Division |
WIRE AND CABLE |
||||||||||||||||||||||||||||||||||||||
|
3m Electronic Products Division |
WIRE AND CABLE |
|||||||||||||||||||||||||||||||||||||||
|
|
Panduit |
CABLE ASSEMBLY |
LC DUPLEX |
LC DUPLEX |
NO |
ISO/IEC; TIA; TIA/EIA |
NO |
70 Cel |
DATA CENTER, HORIZONTAL DISTRIBUTION, TELECOMMUNICATION ROOM |
-20 Cel |
1.6 mm |
2 |
STANDARD: ISO/IEC 11801 |
COMMUNICATION CABLE |
||||||||||||||||||||||||||
|
|
Panduit |
CABLE ASSEMBLY |
LC DUPLEX |
LC DUPLEX |
NO |
ISO/IEC; TIA; TIA/EIA |
NO |
70 Cel |
DATA CENTER, HORIZONTAL DISTRIBUTION, TELECOMMUNICATION ROOM |
-20 Cel |
1.6 mm |
2 |
STANDARD: ISO/IEC 11801 |
COMMUNICATION CABLE |
||||||||||||||||||||||||||
|
|
Alpha Wire |
WIRE AND CABLE |
300 V |
NO |
.129 mm2 |
COPPER ALLOY |
STRANDED |
.135 ohm |
TIN |
POLYVINYLCHLORIDE |
105 Cel |
-40 Cel |
26 |
1.3 mm |
1 |
304.8 mm |
FLEXIBLE CORD AND FIXTURE WIRE |
7X34 |
Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.
Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.
Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.
Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.