| Part | RoHS | Manufacturer | Connector Type | Option | Reliability | Contact Gender | Dielectric Withstanding Voltage (V) | No. of Connectors | Panel Mount | Body Length | Body Diameter | Insulation Resistance | Mixed Contacts | Insertion Loss | EMI Shielded | Filter Feature | Body Width | Termination Contact Finish | Body Depth | MIL Conformity | Coupling Type | Insulator Material | Maximum Operating Temperature (Cel) | DIN Conformance | IEC Conformity | Minimum Operating Temperature | Empty Shell | Shell Finish | No. of Ports | Contact Material | Mating Contact Finish | Polarization Key | Additional Features | Voltage Standing Wave Ratio | Reference Standard | Insulator Color | Total No. of Contacts | Durability | Mounting Type | Characteristic Impedance | Sub-Category | Shell Material | Cable Types | Mating Info. | Mains Connector Rating | Termination Type | Minimum Withdrawal Force (N) | Manufacturer Series | Contact Resistance | Body or Shell Style | Mounting Style | Contact Style | JESD-609 Code | Maximum Insertion Force (N) | Terminal Length | Mounting Option-1 | Maximum Operating Frequency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
.571 inch |
1.103 inch |
POLYTETRAFLUOROETHYLENE |
NICKEL |
1 |
NATURAL |
1 |
CABLE |
RF TNC Connectors |
BRASS |
CRIMP |
122414 |
PLUG |
RIGHT ANGLE |
COAX |
LOCKING |
||||||||||||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
.571 inch |
1.072 inch |
POLYTETRAFLUOROETHYLENE |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
NATURAL |
1 |
CABLE |
RF TNC Connectors |
BRASS |
RG-223/U |
CRIMP |
PLUG |
STRAIGHT |
COAX |
LOCKING |
||||||||||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
FEMALE |
1.103 inch |
POLYTETRAFLUOROETHYLENE |
NICKEL |
1 |
NATURAL |
1 |
CABLE |
RF TNC Connectors |
BRASS |
BELDEN 9913 |
CRIMP |
122416RP |
PLUG |
RIGHT ANGLE |
COAX |
LOCKING |
|||||||||||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
MALE |
700VAC |
POLYTETRAFLUOROETHYLENE |
85 |
-40 Cel |
NICKEL |
1 |
1.3 |
NATURAL |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
RG-316/U |
CRIMP |
122116-15 |
PLUG |
STRAIGHT |
COAX |
LOCKING |
6 GHz |
|||||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
POLYTETRAFLUOROETHYLENE |
165 |
-65 Cel |
NICKEL |
1 |
NATURAL |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
LMR400 |
CRIMP |
122393RP |
PLUG |
STRAIGHT |
COAX |
LOCKING |
11 GHz |
||||||||||||||||||||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
5000000000 ohm |
NO |
NO |
NO |
1.075 inch |
NO |
THREADED |
POLYTETRAFLUOROETHYLENE |
85 |
NO |
NO |
-55 Cel |
YES |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
1 |
50 Cycles |
PANEL |
50 ohm |
RF TNC Connectors |
ZINC ALLOY |
115/230VAC |
SOLDER |
3 mohm |
JACK |
STRAIGHT |
COAX |
.251 inch |
LOCKING |
2 GHz |
||||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
.379 inch |
5000000000 ohm |
NO |
NO |
NO |
.72 inch |
NO |
THREADED |
POLYTETRAFLUOROETHYLENE |
85 |
NO |
NO |
-55 Cel |
YES |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
1 |
50 Cycles |
BOARD |
50 ohm |
RF TNC Connectors |
ZINC ALLOY |
115/230VAC |
SOLDER |
3 mohm |
JACK |
STRAIGHT |
COAX |
.157 inch |
LOCKING |
4 GHz |
|||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
.579 inch |
5000000000 ohm |
NO |
NO |
NO |
.622 inch |
.622 inch |
NO |
THREADED |
POLYESTER |
85 |
NO |
NO |
-55 Cel |
YES |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
POLARIZED HOUSING |
WHITE |
1 |
50 Cycles |
BOARD |
50 ohm |
RF TNC Connectors |
ZINC ALLOY |
115/230VAC |
SOLDER |
3 mohm |
JACK |
RIGHT ANGLE |
COAX |
.141 inch |
LOCKING |
4 GHz |
||||||||||||||
|
|
Molex |
RF TNC CONNECTOR |
COMMERCIAL |
FEMALE |
YES |
.25 dB |
.732 inch |
POLYTETRAFLUOROETHYLENE |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
1.3 |
1 |
BOARD AND PANEL |
50 ohm |
RF TNC Connectors |
BRASS |
SOLDER |
JACK |
RIGHT ANGLE |
COAX |
LOCKING |
6 GHz |
|||||||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
FEMALE |
.709 inch |
POLYTETRAFLUOROETHYLENE |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
NATURAL |
1 |
CABLE |
RF TNC Connectors |
BRASS |
RG-58/U |
CRIMP |
JACK |
STRAIGHT |
COAX |
LOCKING |
||||||||||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
COMMERCIAL |
FEMALE |
.768 inch |
POLYTETRAFLUOROETHYLENE |
NICKEL |
1 |
NATURAL |
1 |
CABLE |
RF TNC Connectors |
BRASS |
RG-178B/U |
CRIMP |
122370RP |
JACK |
STRAIGHT |
COAX |
LOCKING |
|||||||||||||||||||||||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
.64 inch |
5000000000 ohm |
NO |
.18 dB |
NO |
NO |
YES |
THREADED |
POLYTETRAFLUOROETHYLENE |
125 |
NO |
NO |
-55 Cel |
YES |
SILVER |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
COMPATIBLE CONTACT: 1-225467-3, APPLICABLE CABLES: RG 142/U; RG 142A/U; RG 142B/U; RG 400/U |
1.3 |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
PHOSPHOR BRONZE |
RG 400, RG 142, RG 142B, RG 142A |
MULTIPLE MATING PARTS AVAILABLE |
115/230VAC |
CRIMP |
2 mohm |
PLUG |
STRAIGHT |
COAX |
e4 |
8.896 |
LOCKING |
11 GHz |
||||||||||||
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
.64 inch |
5000000000 ohm |
NO |
.18 dB |
NO |
NO |
NOT APPLICABLE |
1.218 inch |
YES |
SNAP |
POLYTETRAFLUOROETHYLENE |
165 |
NO |
NO |
-65 Cel |
YES |
SILVER |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
APPLICABLE CABLES: RG 142/U; RG 142A/U; RG 142B/U |
1.3 |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
RG 142B, RG 142A, RG 142 |
MULTIPLE MATING PARTS AVAILABLE |
115/230VAC |
CRIMP |
2 mohm |
PLUG |
RIGHT ANGLE |
COAX |
LOCKING |
11 GHz |
|||||||||||||
|
|
Huber+suhner Ag |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
YES |
NO |
Gold (Au) - with Nickel (Ni) barrier |
.626 inch |
YES |
THREADED |
PERFLUOROALKOXY/POLYTETRAFLUORO ETHYLENE |
165 |
NO |
YES |
-65 Cel |
1 |
BERYLLIUM COPPER |
GOLD OVER NICKEL |
STANDARDS: IEC 60169-17; MIL-STD-348A/313, VSWR MAX AT: 2.5 GHZ |
1.04 |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
SOLDER |
JACK |
STRAIGHT |
COAX |
e4 |
.3 inch |
11 GHz |
|||||||||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
NO |
.581 inch |
NO |
NO |
NO |
.625 inch |
NOT APPLICABLE |
.625 inch |
NO |
SCREW |
POLYMETHYLPENTENE |
85 |
NO |
NO |
-55 Cel |
YES |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
1 |
PANEL |
50 ohm |
RF TNC Connectors |
ZINC ALLOY |
115/230VAC |
SOLDER |
JACK |
STRAIGHT |
COAX |
.162 inch |
LOCKING |
11 GHz |
||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
YES |
NO |
.709 inch |
NO |
THREADED |
POLYTETRAFLUOROETHYLENE |
NO |
NO |
NICKEL |
1 |
NOT SPECIFIED |
APPLICABLE CABLES: RG-142/U; RG-223/U; RG-400/U |
NATURAL |
1 |
CABLE AND PANEL |
RF TNC Connectors |
BRASS |
RG-142/U |
CRIMP |
JACK |
STRAIGHT |
COAX |
LOCKING |
|||||||||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
NO |
NO |
1.497 inch |
NO |
THREADED |
POLYTETRAFLUOROETHYLENE |
NO |
NO |
NICKEL |
1 |
NATURAL |
1 |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
BELDEN 9913 |
CLAMP |
122397 |
PLUG |
STRAIGHT |
COAX |
LOCKING |
|||||||||||||||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
.64 inch |
NO |
NO |
NO |
NOT APPLICABLE |
1.375 inch |
YES |
THREADED |
POLYTETRAFLUOROETHYLENE |
85 |
NO |
NO |
-55 Cel |
YES |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
POLARIZED HOUSING |
APPLICABLE CABLES: RG 142/U, 142A/U, 142B/U |
1 |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
RG 142B, RG 142, RG 142A |
115/230VAC |
CRIMP |
PLUG |
STRAIGHT |
COAX |
LOCKING |
11 GHz |
|||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
ONE |
YES |
NO |
NO |
NO |
NOT APPLICABLE |
YES |
SCREW |
PTFE |
85 |
NO |
NO |
-55 Cel |
NO |
NICKEL |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
POLARIZED HOUSING |
APPLICABLE CABLES: RG 142/U, RG 142B/U |
1 |
PANEL |
50 ohm |
RF TNC Connectors |
BRASS |
RG 142B, RG 142 |
CRIMP |
JACK |
STRAIGHT |
COAX |
LOCKING |
11 GHz |
||||||||||||||||||||
|
|
Huber+suhner Ag |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
NO |
.63 inch |
NO |
Gold (Au) - with Nickel (Ni) barrier |
1.067 inch |
NO |
THREADED |
PERFLUOROALKOXY/POLYTETRAFLUORO ETHYLENE |
165 |
NO |
NO |
-65 Cel |
1 |
BRASS |
GOLD OVER NICKEL |
APPLICABLE CABLE: RG 400 /U, VSWR MAX AT 11 GHZ |
1.43 |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
RG-223/U |
CLAMP SOLDER |
PLUG |
RIGHT ANGLE |
COAX |
e4 |
.531 inch |
LOCKING |
11 GHz |
||||||||||||||||||||
|
|
Huber+suhner Ag |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
NO |
.633 inch |
NO |
Gold (Au) |
1.065 inch |
NO |
THREADED |
PERFLUOROALKOXY/POLYTETRAFLUORO ETHYLENE |
165 |
NO |
NO |
-65 Cel |
1 |
NOT SPECIFIED |
GOLD |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
RG-400/U |
CLAMP SOLDER |
PLUG |
RIGHT ANGLE |
COAX |
e4 |
LOCKING |
11 GHz |
|||||||||||||||||||||||
|
|
Huber+suhner Ag |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
FEMALE |
YES |
NO |
Gold (Au) - with Nickel (Ni) barrier |
.717 inch |
YES |
THREADED |
PERFLUOROALKOXY/POLYTETRAFLUORO ETHYLENE |
165 |
NO |
YES |
-65 Cel |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
STANDARDS: IEC 60169-17; MIL-STD-348A/313 |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
SOLDER |
JACK |
STRAIGHT |
COAX |
e4 |
.347 inch |
LOCKING |
11 GHz |
|||||||||||||||||||||||
|
|
Amphenol |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
NO |
.571 inch |
NO |
GOLD |
NO |
THREADED |
ACETAL |
NO |
NO |
NICKEL |
1 |
GOLD |
APPLICABLE CABLES: RG 174/U, RG 188A/U, RG 316/U |
NATURAL |
1 |
CABLE |
Other RF Connectors |
BRASS |
RG-174/U |
CRIMP |
122375 |
PLUG |
STRAIGHT |
COAX |
e4 |
LOCKING |
||||||||||||||||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
ONE |
NO |
.64 inch |
5000000000 ohm |
NO |
.18 dB |
NO |
NO |
NOT APPLICABLE |
YES |
THREADED |
POLYTETRAFLUOROETHYLENE |
125 |
NO |
NO |
-55 Cel |
YES |
SILVER |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
APPLICABLE CABLES: RG 142/U; RG 142A/U; RG 142B/U; RG 400/U |
1.3 |
1 |
500 Cycles |
CABLE |
50 ohm |
RF TNC Connectors |
BRASS |
RG 142A, RG 400, RG 142B, RG 142 |
115/230VAC |
CRIMP |
.556 |
1.5 mohm |
PLUG |
STRAIGHT |
COAX |
8.896 |
LOCKING |
11 GHz |
||||||||||||
|
|
TE Connectivity |
RF TNC CONNECTOR |
GENERAL PURPOSE |
COMMERCIAL |
MALE |
NO |
5000000000 ohm |
.2 dB |
NO |
GOLD |
.817 inch |
NO |
THREADED |
POLYTETRAFLUOROETHYLENE |
165 |
NO |
NO |
-65 Cel |
1 |
NOT SPECIFIED |
NOT SPECIFIED |
1.3 |
1 |
CABLE |
50 ohm |
RF TNC Connectors |
STEEL |
CLAMP SOLDER |
1.5 mohm |
PLUG |
STRAIGHT |
COAX |
.933 inch |
LOCKING |
15 GHz |
TNC connectors are a type of threaded RF (radio frequency) connector used for terminating coaxial cables. They are similar in design to the BNC connector but feature a threaded coupling mechanism for a more secure and stable connection.
TNC connectors consist of a male and female connector, with the male connector featuring a center pin that plugs into the female connector, which has a socket to receive the pin. They are typically available in 50 ohm and 75 ohm versions, and can be used for both DC and high-frequency signals.
One advantage of TNC connectors is their threaded coupling mechanism, which ensures a stable and secure connection that can withstand vibration and other stresses. They are also designed to provide a low-loss signal transmission, making them a popular choice for many high-performance applications.
TNC connectors are commonly used in a variety of industrial and commercial applications, including telecommunications, data centers, and military and aerospace applications. They may be subject to rigorous testing and qualification requirements to ensure their reliability and performance.