Part RoHS Manufacturer Peripheral IC Type Temperature Grade Terminal Form No. of Terminals Package Code Package Shape Package Body Material Surface Mount Maximum Supply Voltage Screening Level Address Bus Width No. of Bits DAC Channels Bit Size Power Supplies (V) Package Style (Meter) Package Equivalence Code Minimum Supply Voltage Maximum Operating Temperature CPU Family Maximum Data Transfer Rate Minimum Operating Temperature Terminal Finish ADC Channels Terminal Position DMA Channels Maximum Seated Height ROM Words Width Data EEPROM Size Additional Features Peripherals External Data Bus Width Maximum Clock Frequency Maximum Time At Peak Reflow Temperature (s) Peak Reflow Temperature (C) Length RAM Bytes Technology Maximum Supply Current Nominal Supply Voltage PWM Channels Sub-Category Connectivity ROM Programmability Bus Compatibility Terminal Pitch JESD-30 Code Moisture Sensitivity Level (MSL) Qualification Speed Drive Interface Standard JESD-609 Code On Chip Program ROM Width No. of I/O Lines

PEX8696-AA50RBCG

Broadcom

BUS CONTROLLER, PCI

BALL

1156

HBGA

SQUARE

PLASTIC/EPOXY

YES

1.05 V

0

GRID ARRAY, HEAT SINK/SLUG

BGA1156,34X34,40

.95 V

70 Cel

.0125 MBps

0 Cel

BOTTOM

2.85 mm

35 mm

0

250 MHz

35 mm

CMOS

1 V

I2C, SMBUS, SPI, USB

1 mm

S-PBGA-B1156

PEX8764-AB80BIG

Broadcom

BUS CONTROLLER, PCI

BALL

1156

BGA

SQUARE

PLASTIC/EPOXY

YES

0

GRID ARRAY

TIN SILVER COPPER

BOTTOM

0

245

CMOS

I2C

S-PBGA-B1156

4

e1

PEX8796-AB80BIG

Broadcom

BUS CONTROLLER, PCI

BALL

1156

BGA

SQUARE

PLASTIC/EPOXY

YES

0

GRID ARRAY

TIN SILVER COPPER

BOTTOM

0

245

CMOS

I2C

S-PBGA-B1156

4

e1

PEX8625-AA50RBCF

Broadcom

BUS CONTROLLER, PCI

COMMERCIAL

BALL

1156

HBGA

SQUARE

PLASTIC/EPOXY

YES

1.05 V

0

GRID ARRAY, HEAT SINK/SLUG

BGA1156,34X34,40

.95 V

70 Cel

.0125 MBps

0 Cel

BOTTOM

2.85 mm

35 mm

0

245

35 mm

CMOS

1 V

I2C; SMBUS; SPI; VGA

1 mm

S-PBGA-B1156

4

IEEE 1149.6; IEEE 1149.1

PEX8696-AA50RBCF

Broadcom

BUS CONTROLLER, PCI

COMMERCIAL

BALL

1156

HBGA

SQUARE

PLASTIC/EPOXY

YES

1.05 V

0

GRID ARRAY, HEAT SINK/SLUG

BGA1156,34X34,40

.95 V

70 Cel

.0125 MBps

0 Cel

TIN SILVER COPPER

BOTTOM

2.85 mm

35 mm

0

35 mm

CMOS

1 V

I2C; SMBUS; SPI; USB

1 mm

S-PBGA-B1156

4

IEEE 1149.6; IEEE 1149.1

e1

PEX8680-AA50RBCG

Broadcom

BUS CONTROLLER, PCI

BALL

1156

HBGA

SQUARE

PLASTIC/EPOXY

YES

1.05 V

0

GRID ARRAY, HEAT SINK/SLUG

BGA1156,34X34,40

.95 V

70 Cel

0 Cel

BOTTOM

2.85 mm

35 mm

0

250 MHz

245

35 mm

CMOS

1 V

I2C, PCI, SMBUS

1 mm

S-PBGA-B1156

PEX8680-AA50RBCF

Broadcom

BUS CONTROLLER, PCI

BALL

1156

HBGA

SQUARE

PLASTIC/EPOXY

YES

1.05 V

0

GRID ARRAY, HEAT SINK/SLUG

BGA1156,34X34,40

.95 V

70 Cel

0 Cel

BOTTOM

2.85 mm

35 mm

0

250 MHz

245

35 mm

CMOS

1 V

I2C, PCI, SMBUS

1 mm

S-PBGA-B1156

4

Bus Controllers

Bus controllers are integrated circuits that are used to manage and control the flow of data and control signals between different devices in a computer system. They are commonly used in systems that have multiple buses, such as a memory bus and an I/O bus. Bus controllers ensure that data is transferred efficiently and correctly between different devices in the system.

One of the primary functions of a bus controller is to manage bus arbitration. Bus arbitration is the process of resolving conflicts that occur when two or more devices on the bus attempt to access the bus at the same time. Bus controllers use various algorithms to determine which device has priority access to the bus and when other devices can access it.

Another important function of bus controllers is to manage the transfer of data and control signals between devices on the bus. This involves controlling the timing and synchronization of signals, as well as error detection and correction. Bus controllers also manage other aspects of the bus, such as interrupt handling and power management.