Latched Power & Signal Relays 300

Reset All
Part RoHS Manufacturer Relay Type Mounting Feature Relay Action Relay Function Coil or Input Supply Type Reference Standard Maximum Contact AC Rating (R Load) Dielectric Strength Between Open Contacts AC Coil Release Voltage Relay Form AC Coil Operate Voltage Operate Time Maximum Contact AC Rating (M Load) Electrical Life Maximum Contact DC Power Rating (R Load) Release Time Insulation Resistance Coil Power (mW) Packing Method Body Length/Diameter Body Width Coil Resistance Sealing Weight Maximum AC Coil Current No. of Terminals Physical Dimension End Contact Plating Body Height Dielectric Strength Between Coil & Contacts Maximum Contact DC Rating (R Load) Maximum Operating Temperature Maximum AC Contact Current Maximum DC Coil Current Maximum AC Coil Voltage Maximum Contact AC Rating (I Load) Minimum Operating Temperature DC Coil Release Voltage Terminal Finish Maximum DC Contact Current Termination Type Maximum Contact AC Power Rating (M Load) Nominal Coil Voltage DC Coil Operate Voltage Manufacturer Series Contact Resistance Input Switching Control Type End Contact Material PCB Hole Count Maximum DC Contact Voltage Additional Features Maximum AC Contact Voltage JESD-609 Code Minimum Operating Frequency Terminal Length Maximum DC Coil Voltage Maximum Operating Frequency Maximum Contact AC Power Rating (R Load) Contact or Output Supply Type

DSP1A-DC24V-R

Panasonic

Power/Signal Relay

Latched

SPST

DC

CSA; TUV; UL

8A@250VAC

1 kVrms

1 Form A

10 ms

100000 Cycle(s)

150W@125VDC

5 ms

1 GΩ

0.795 in (20.2 mm)

11 in (279.4 mm)

1.92 kΩ

4.5 g

4

0.795 x 0.433 x 0.413 in (20.2 x 11 x 10.5 mm)

Gold

0.413 in (10.5 mm)

3 kVrms

5A@125VDC

60 °C (140 °F)

8 A

-40 °C (-40 °F)

2.4 V

5 A

Solder

24 V

19.2 V

30 mΩ

Random

Silver Tin Oxide

4

125 V

250 V

0.1378 in (3.5 mm)

31.2 V

2000VA@250VAC

AC/DC

G2R-1-EZDC24

Omron

Power/Signal Relay

Latched

SPST

DC

CSA; TUV; UL; VDE

16A@380VAC

1 kVrms

1 Form A

15 ms

100000 Cycle(s)

5 ms

1 GΩ

Tray

1.142 in (29 mm)

13.5 in (342.9 mm)

17 g

6

1.142 x 0.531 x 1.004 in (29 x 13.5 x 25.5 mm)

1.004 in (25.5 mm)

5 kVrms

16A@125VDC

70 °C (158 °F)

16 A

-40 °C (-40 °F)

16 A

Solder

24 V

50 mΩ

Random

Silver Alloy

125 V

380 V

0.1575 in (4 mm)

AC/DC

DSP2A-DC24V-R

Panasonic

Power/Signal Relay

Through Hole-Straight Mount

Latched

DPST

DC

CSA; TUV; UL

5A@250VAC

1 kVrms

2 Form A

10 ms

100000 Cycle(s)

150W@125VDC

5 ms

1 GΩ

300 mW

Box

0.795 in (20.2 mm)

11 in (279.4 mm)

1.92 kΩ

4.5 g

6

0.795 x 0.433 x 0.413 in (20.2 x 11 x 10.5 mm)

Gold

0.413 in (10.5 mm)

3 kVrms

5A@125VDC

60 °C (140 °F)

5 A

13 mA

-40 °C (-40 °F)

2.4 V

5 A

Solder

24 V

19.2 V

30 mΩ

Random

Silver Tin Oxide

6

125 V

250 V

0.1378 in (3.5 mm)

31.2 V

1250VA@250VAC

AC/DC

AZ2850-2A-12DE

American Zettler

Power/Signal Relay

Latched

DPST

DC

UL; VDE

1.5 kVrms

2 Form A

15 ms

100000 Cycle(s)

560W@30VDC

10 ms

1 GΩ

2.071 in (52.6 mm)

34.8 in (883.92 mm)

86 Ω

Epoxy

86 g

16

2.071 x 1.37 x 1.039 in (52.6 x 34.8 x 26.4 mm)

1.039 in (26.4 mm)

4 kVrms

85 °C (185 °F)

-40 °C (-40 °F)

Solder

12 V

9 V

AZ2850

50 mΩ

Random

Silver Cadmium Oxide

16

0.3307 in (8.4 mm)

20.7 V

8310VA@600VAC

AC/DC

AZ2850-2AE-24DE

American Zettler

Power/Signal Relay

Through Hole-Straight Mount

Latched

DPST

DC

UL; VDE

1.5 kVrms

2 Form A

15 ms

100000 Cycle(s)

560W@30VDC

10 ms

1 GΩ

1.646 W

2.071 in (52.6 mm)

34.8 in (883.92 mm)

350 Ω

Epoxy

86 g

16

2.071 x 1.37 x 1.039 in (52.6 x 34.8 x 26.4 mm)

1.039 in (26.4 mm)

4 kVrms

85 °C (185 °F)

30 A

68 mA

-40 °C (-40 °F)

Tin

30 A

Solder

24 V

18 V

50 mΩ

Random

Silver Tin Oxide

16

30 V

600 V

e3

0.3307 in (8.4 mm)

41.8 V

8310VA@600VAC

AC/DC

AZ9871-1C-12DET

American Zettler

Power/Signal Relay

Latched

SPDT

DC

500 Vrms

1 Form C

3 ms

100000 Cycle(s)

420W@14VDC

1.5 ms

1 GΩ

0.508 in (12.9 mm)

12 in (304.8 mm)

254 Ω

Epoxy

4 g

5

0.508 x 0.472 x 0.406 in (12.9 x 12 x 10.3 mm)

0.406 in (10.3 mm)

500 Vrms

30A@14VDC

105 °C (221 °F)

-40 °C (-40 °F)

30 A

Solder

12 V

6.9 V

AZ9871

50 mΩ

Random

Silver Tin Oxide

5

14 V

0.0028 in (0.071 mm)

14.4 V

DC

MY2NDC24

Omron

Power/Signal Relay

Panel Mount

Latched

DPDT

DC

CE; CSA; UL; VDE

5A@220VAC

20 ms

500000 Cycle(s)

20 ms

900 mW

1.102 in (28 mm)

21.5 in (546.1 mm)

662 Ω

Moisture Proof

1.102 x 0.846 x 1.417 in (28 x 21.5 x 36 mm)

1.417 in (36 mm)

5A@24VDC

70 °C (158 °F)

5 A

36 mA

-55 °C (-67 °F)

2.4 V

5 A

Solder

19.2 V

24 V

Built-In Indicator

220 V

24 V

AC/DC

ADJH21012

Panasonic

Power/Signal Relay

Through Hole-Straight Mount

Latched

SPST

DC

CUL; UL; VDE

50A@480VAC

20 ms

10000 Cycle(s)

20 ms

1 W

Box

1.535 in (39 mm)

15 in (381 mm)

144 Ω

Moisture Proof

1.535 x 0.591 x 1.189 in (39 x 15 x 30.2 mm)

1.189 in (30.2 mm)

85 °C (185 °F)

50 A

83 mA

-40 °C (-40 °F)

9 V

Solder

9 V

480 V

12 V

AC

G2R-1-ZDC12

Omron

Power/Signal Relay

Latched

SPST

DC

CSA; TUV; UL; VDE

5A@380VAC

1 kVrms

1 Form A

15 ms

100000 Cycle(s)

5 ms

1 GΩ

Tray

1.142 in (29 mm)

13.5 in (342.9 mm)

17 g

6

1.142 x 0.531 x 1.004 in (29 x 13.5 x 25.5 mm)

1.004 in (25.5 mm)

5 kVrms

5A@125VDC

70 °C (158 °F)

5 A

-40 °C (-40 °F)

5 A

Solder

12 V

50 mΩ

Random

Silver Alloy

125 V

380 V

0.1575 in (4 mm)

AC/DC

G2R-1AZ4DC12

Omron

Power/Signal Relay

Latched

SPST

DC

CSA; TUV; UL; VDE

5A@380VAC

1 kVrms

1 Form A

15 ms

100000 Cycle(s)

5 ms

1 GΩ

Tray

1.142 in (29 mm)

13.5 in (342.9 mm)

17 g

6

1.142 x 0.531 x 1.004 in (29 x 13.5 x 25.5 mm)

1.004 in (25.5 mm)

5 kVrms

5A@125VDC

70 °C (158 °F)

5 A

-40 °C (-40 °F)

5 A

Solder

12 V

50 mΩ

Random

Silver Alloy

125 V

380 V

0.1575 in (4 mm)

AC/DC

G2R-1Z4DC12

Omron

Power/Signal Relay

Latched

SPST

DC

CSA; TUV; UL; VDE

5A@380VAC

1 kVrms

1 Form A

15 ms

100000 Cycle(s)

5 ms

1 GΩ

Tray

1.142 in (29 mm)

13.5 in (342.9 mm)

17 g

6

1.142 x 0.531 x 1.004 in (29 x 13.5 x 25.5 mm)

1.004 in (25.5 mm)

5 kVrms

5A@125VDC

70 °C (158 °F)

5 A

-40 °C (-40 °F)

5 A

Solder

12 V

50 mΩ

Random

Silver Alloy

125 V

380 V

0.1575 in (4 mm)

AC/DC

G2R-2-ZDC24

Omron

Power/Signal Relay

Latched

SPDT

DC

CSA; TUV; UL; VDE

5A@380VAC

1 kVrms

1 Form C

15 ms

100000 Cycle(s)

5 ms

1 GΩ

Tray

1.142 in (29 mm)

13.5 in (342.9 mm)

17 g

6

1.142 x 0.531 x 1.004 in (29 x 13.5 x 25.5 mm)

1.004 in (25.5 mm)

5 kVrms

5A@125VDC

70 °C (158 °F)

5 A

-40 °C (-40 °F)

5 A

Solder

24 V

50 mΩ

Random

Silver Alloy

125 V

380 V

0.1575 in (4 mm)

AC/DC

Power & Signal Relays

Power and signal relays are electromechanical switches that are used to control power circuits and signal circuits respectively. Power relays are designed to handle higher voltages and currents, typically in the range of several hundred volts and amperes. They are commonly used in industrial and automotive applications to switch on/off motors, heaters, lights, and other high-power loads. Signal relays, on the other hand, are designed to handle lower voltages and currents, typically in the range of several volts and milliamperes. They are commonly used in electronic equipment such as computers, telecommunications equipment, and consumer electronics to switch on/off signals, data, and low-power loads.

Power and signal relays come in different types and configurations depending on the specific application requirements. Some common types include electromechanical relays, reed relays, solid-state relays, and latching relays. Electromechanical relays use a mechanical switching mechanism, typically a set of contacts that move to make or break an electrical circuit. Reed relays use a set of magnetically activated contacts that are enclosed in a sealed glass tube. Solid-state relays use a semiconductor device to switch on/off the load. Latching relays use a magnetic field to hold the contacts in either the open or closed position, eliminating the need for continuous power to maintain the relay's state.

Power and signal relays play a critical role in the overall performance and reliability of electrical and electronic systems. The selection of the appropriate relay for a given application is crucial to ensure proper operation, safety, and longevity of the system. Factors to consider when selecting a relay include the load current and voltage, switching frequency, contact rating, switching speed, contact bounce, and environmental conditions such as temperature, humidity, and vibration. Proper maintenance and testing of relays are also important to ensure their continued performance and reliability over time.