| Part | RoHS | Manufacturer | Transformer Type | Mounting Feature | Manufacturer Series | Approvals (V) | Terminal Finish | Power Rating | Center Tap Feature-2 | No. of Functions | No. of Winding (Primary) | Isolation Voltage | Inductance (Primary) | Packing Method | Output Current-1 | Minimum ET Product | Output Current-2 | No. of Winding (Secondary) | Sub-Category | Dimensions | Volt-Ampere Rating (VA) | Maximum Operating Temperature | Center Tap Feature-1 | Application | Output Voltage-2 | Output Voltage-1 | Minimum Operating Temperature | Nominal Operating Frequency | Rating (Primary) | Height | Width | Diameter | Nominal Input Voltage (V) | Load Resistance | Additional Features | Minimum Input Voltage (V) | JESD-609 Code | Minimum Operating Frequency | Length | Turns Ratio (Np:Ns) | Maximum Operating Frequency | Maximum Input Voltage (V) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
Triad Magnetics |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA, UL |
NO |
1 |
1500 V |
1.67 A |
1 |
Other Transformers |
D92.5XH56.5 (mm) |
40 VA |
NO |
POWER |
24 V |
50/60 HZ |
SINGLE 120V |
56.5 mm |
59.44 mm |
92.5 mm |
92.46 mm |
120 |
||||||||||||||||||||
|
|
Triad Magnetics |
POWER TRANSFORMER |
CHASSIS MOUNT |
CE, TUV |
NO |
2 |
3500 V |
4.116 A |
4.116 A |
2 |
L101.6XB57.15XH65.07 (mm) |
50 VA |
NO |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
65.07 mm |
57.15 mm |
115/230 |
101.6 mm |
||||||||||||||||||||
|
|
Triad Magnetics |
POWER TRANSFORMER |
CHASSIS MOUNT |
CUL; TUV; UL |
NO |
2 |
3500 V |
.42 A |
.42 A |
2 |
L60.32XB36.5XH36.5 (mm) |
5 VA |
NO |
POWER |
12 V |
12 V |
50/60 HZ |
DUAL 115V |
36.5 mm |
36.5 mm |
115/230 |
60.32 mm |
||||||||||||||||||||
|
Hammond Manufacturing |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA |
YES |
2000 V |
3 A |
.287 A |
2 |
116 VA |
YES |
5 V |
360 V |
60 HZ |
SINGLE 115V |
77.724 mm |
63.5 mm |
115 |
95.25 mm |
||||||||||||||||||||||||
|
|
Hammond Manufacturing |
POWER TRANSFORMER |
CHASSIS MOUNT |
CSA |
YES |
2000 V |
6 A |
.23 A |
3 |
229 VA |
YES |
6.3 V |
800 V |
60 HZ |
SINGLE 115V |
96.774 mm |
79.502 mm |
115 |
101.6 mm |
|||||||||||||||||||||||
|
Pico Electronics |
POWER TRANSFORMER |
SURFACE MOUNT |
MIL-PRF-27 |
Tin/Lead (Sn/Pb) |
NO |
.0353 A |
2 |
L25.4XB20.32XH23.24 (mm) |
2.4 VA |
90 Cel |
YES |
68 V |
400 HZ |
SINGLE 26V |
23.24 mm |
20.32 mm |
26 |
e0 |
20.32 mm |
|||||||||||||||||||||||
|
Tamura |
POWER TRANSFORMER |
UL; CSA |
.045 A |
2 |
1.1 VA |
60 HZ |
PCB MOUNTABLE |
|||||||||||||||||||||||||||||||||||
|
Tamura |
POWER TRANSFORMER |
UL; CSA |
.023 A |
2 |
1.1 VA |
60 HZ |
PCB MOUNTABLE |
|||||||||||||||||||||||||||||||||||
|
Tamura |
POWER TRANSFORMER |
UL; CSA |
1 A |
2 |
12 VA |
60 HZ |
PCB MOUNTABLE |
|||||||||||||||||||||||||||||||||||
|
Tamura |
POWER TRANSFORMER |
UL; CSA |
.05 A |
1 |
.7 VA |
60 HZ |
PCB MOUNTABLE |
|||||||||||||||||||||||||||||||||||
|
|
Hammond Manufacturing |
POWER TRANSFORMER |
PLUG-IN MOUNT |
CSA; UL |
NO |
.83 A |
1 |
20 VA |
NO |
24 V |
60 HZ |
SINGLE 120V |
120 |
|||||||||||||||||||||||||||||
|
|
TE Connectivity |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
BULK |
12 VA |
YES |
6 V |
6 V |
DUAL 115/230V |
||||||||||||||||||||||||||||||||
|
Pico Electronics |
POWER TRANSFORMER |
76000 |
||||||||||||||||||||||||||||||||||||||||
|
|
Hammond Manufacturing |
POWER TRANSFORMER |
PORTABLE MOUNT |
CUL: UL |
1 |
Other Transformers |
260.3mm x 190.5mm x 127mm |
1000 VA |
ISOLATION |
240 V |
50/60 HZ |
SINGLE 240V |
127 mm |
190.5 mm |
240 |
260.35 mm |
240 |
|||||||||||||||||||||||||
|
|
Murrelektronik |
POWER TRANSFORMER |
CHASSIS MOUNT |
CUL; EN; UL |
NO |
4000 V |
2 |
63 VA |
40 Cel |
NO |
115 V |
115 V |
-20 Cel |
50-60 HZ |
SINGLE 208-550V |
93 mm |
78 mm |
208/230/380/400/420/440/550 |
Additional Input voltage nom range is "460, 480, 500, 525V AC" |
97 mm |
||||||||||||||||||||||
|
|
TE Connectivity |
POWER TRANSFORMER |
CHASIS MOUNT |
BULK |
50 VA |
24 V |
208/240 |
|||||||||||||||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
44000 |
NO |
63 A |
63 A |
2 |
L32.6XB27.6XH24.3 (mm) |
1.5 VA |
NO |
12 V |
12 V |
SINGLE 230V |
24.3 mm |
27.6 mm |
32.6 mm |
|||||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
NO |
.107 A |
.107 A |
2 |
L41.0XB35.0XH28.0 (mm) |
3.2 VA |
70 Cel |
NO |
15 V |
15 V |
50/60 HZ |
SINGLE 230V |
28 mm |
35 mm |
41 mm |
||||||||||||||||||||||||
|
|
Emerson Electric |
POWER TRANSFORMER |
CHASSIS MOUNT |
UL; CSA; IEC; CE |
NO |
1 |
L152.4XB162.05XH143.0 (mm) |
750 VA |
YES |
120 V |
60 HZ |
SINGLE 208/240/415/480/600V |
143 mm |
162.05 mm |
152.4 mm |
|||||||||||||||||||||||||||
|
|
Emerson Electric |
POWER TRANSFORMER |
CHASSIS MOUNT |
UL; CSA; IEC; CE |
NO |
2 |
L171.45XB162.05XH143.0 (mm) |
1500 VA |
NO |
115 V |
230 V |
50/60 HZ |
SINGLE 230/400/460V |
143 mm |
162.05 mm |
171.45 mm |
||||||||||||||||||||||||||
|
|
Emerson Electric |
POWER TRANSFORMER |
CHASSIS MOUNT |
UL; CSA; IEC; CE |
NO |
2 |
L171.45XB162.05XH143.0 (mm) |
1500 VA |
NO |
115 V |
230 V |
50/60 HZ |
SINGLE 200/230/400/460/575V |
143 mm |
162.05 mm |
171.45 mm |
||||||||||||||||||||||||||
|
|
Tamura |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, TUV, UL |
NO |
4 A |
.68 A |
2 |
56 VA |
YES |
9.3 V |
27.5 V |
50/60 HZ |
DUAL 115V |
48.5 mm |
64 mm |
115/230 |
76.2 mm |
||||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL, VDE |
NO |
4000 V |
1.667 A |
1.667 A |
2 |
40 VA |
50 Cel |
NO |
12 V |
12 V |
DUAL 115V |
38.5 mm |
70 mm |
115 |
PARALLEL CONNECTED |
83 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL, VDE |
NO |
4000 V |
2 A |
2 A |
2 |
60 VA |
50 Cel |
NO |
15 V |
15 V |
DUAL 115V |
48.5 mm |
70 mm |
115 |
PARALLEL CONNECTED |
86 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
.667 A |
.667 A |
2 |
24 VA |
50 Cel |
NO |
18 V |
18 V |
DUAL 115V |
31 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
1.25 A |
1.25 A |
2 |
30 VA |
50 Cel |
NO |
12 V |
12 V |
DUAL 115V |
35 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
.416 A |
.416 A |
2 |
10 VA |
50 Cel |
NO |
12 V |
12 V |
DUAL 115V |
22 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
.6 A |
.6 A |
2 |
18 VA |
50 Cel |
NO |
15 V |
15 V |
DUAL 115V |
27 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
1.667 A |
1.667 A |
2 |
30 VA |
50 Cel |
NO |
9 V |
9 V |
DUAL 115V |
35 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL, VDE |
NO |
4000 V |
.278 A |
.278 A |
2 |
10 VA |
50 Cel |
NO |
18 V |
18 V |
DUAL 115V |
28 mm |
44 mm |
115 |
PARALLEL CONNECTED |
53 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
.208 A |
.208 A |
2 |
10 VA |
50 Cel |
NO |
24 V |
24 V |
DUAL 115V |
22 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
.583 A |
.583 A |
2 |
14 VA |
50 Cel |
NO |
12 V |
12 V |
DUAL 115V |
24 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
UL |
NO |
4000 V |
1 A |
1 A |
2 |
30 VA |
50 Cel |
NO |
15 V |
15 V |
DUAL 115V |
35 mm |
57 mm |
115 |
PARALLEL CONNECTED |
68 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL, VDE |
NO |
4000 V |
.063 A |
.063 A |
2 |
3 VA |
70 Cel |
NO |
24 V |
24 V |
DUAL 115V |
17 mm |
44 mm |
115 |
PARALLEL CONNECTED |
53 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CSA, UL, VDE |
NO |
4000 V |
.2 A |
.2 A |
2 |
6 VA |
70 Cel |
NO |
15 V |
15 V |
DUAL 115V |
22 mm |
44 mm |
115 |
PARALLEL CONNECTED |
53 mm |
||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
EN; UL |
NO |
1.333 A |
2 |
16 VA |
50 Cel |
NO |
6 V |
6 V |
50-60 HZ |
SINGLE 230V |
38.75 mm |
47.25 mm |
230 |
56.5 mm |
||||||||||||||||||||||||
|
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE; CSA; EN; UL; VDE |
NO |
.417 A |
1 |
5 VA |
50 Cel |
NO |
12 V |
-25 Cel |
50/60 HZ |
SINGLE 230V |
32.3 mm |
37 mm |
230 |
44 mm |
||||||||||||||||||||||||
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
EN; UL |
NO |
.083 A |
2 |
2 VA |
70 Cel |
NO |
12 V |
12 V |
50/60 HZ |
SINGLE 230V |
27.3 mm |
27.6 mm |
32.6 mm |
||||||||||||||||||||||||||
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
EN; UL |
NO |
.056 A |
2 |
2 VA |
70 Cel |
NO |
18 V |
18 V |
50/60 HZ |
SINGLE 230V |
27.3 mm |
27.6 mm |
32.6 mm |
||||||||||||||||||||||||||
|
|
Wurth Elektronik |
POWER TRANSFORMER |
SURFACE MOUNT |
AEC-Q200 |
YES |
4300 V |
TR, EMBOSSED PLASTIC, 13 INCH |
2 |
125 Cel |
YES |
-40 Cel |
3.45 mm |
14.7 mm |
1000 |
15.1 mm |
|||||||||||||||||||||||||||
|
Myrra Sas |
POWER TRANSFORMER |
THROUGH HOLE MOUNTED |
CE; CSA; EN; UL; VDE |
NO |
2 |
1.5 VA |
70 Cel |
NO |
6 V |
6 V |
-25 Cel |
50/60 HZ |
SINGLE 230V |
23.8 mm |
26.7 mm |
230 |
31.7 mm |
Power and mains transformers are types of electrical transformers used in power transmission and distribution systems to convert high voltage and low current to low voltage and high current or vice versa. They are essential components in the electricity grid, and are used to step up or step down voltage levels for efficient transmission and distribution of electrical energy.
Power transformers are used in high voltage transmission systems, typically at voltages of 110 kV and above, to step up or step down the voltage levels. They have a high power rating, typically ranging from several hundred kVA to several thousand MVA, and are designed to handle high currents and voltages without overheating or breaking down. Power transformers are typically oil-immersed, and use a magnetic core made of laminated steel to reduce losses and improve efficiency.
Mains transformers, also known as distribution transformers, are used in low voltage distribution systems, typically at voltages of 11 kV or below, to step down the voltage levels for use by consumers. They have a lower power rating than power transformers, typically ranging from several kVA to several hundred kVA, and are designed to operate at lower voltages and currents. Mains transformers are typically dry-type, and use a magnetic core made of laminated steel or ferrite to reduce losses and improve efficiency.
Both power and mains transformers require proper design, selection, and maintenance to ensure reliable and efficient operation. They are subject to various standards and regulations, such as IEC (International Electrotechnical Commission) and IEEE (Institute of Electrical and Electronics Engineers), to ensure their safety and performance. Proper installation and maintenance of transformers, such as regular inspection, testing, and oil analysis, are also critical to ensure their longevity and performance.