TIN Pulse & Datacom Transformers 14

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Impedance (Primary) Power Rating No. of Functions Impedance (Secondary) No. of Winding (Primary) Maximum Pulse Rise Time Isolation Voltage Insertion Loss Inductance (Primary) Packing Method Output Current-1 Minimum ET Product Output Current-2 Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Maximum Operating Temperature Application Output Voltage-1 Minimum Operating Temperature Height Width Nominal Input Voltage (V) Load Resistance Additional Features Minimum Input Voltage (V) JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency Maximum Input Voltage (V)

IL-10-0002

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

TIN

1

700 ns

3500 V

16500 uH

BULK

200 V-us

L18.5XB17.5XH11.1 (mm)

70 Cel

GENERAL PURPOSE

-25 Cel

11.5 mm

17.5 mm

380

e3

18.5 mm

3:1:1

IL-10-0003

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

TIN

1

1000 ns

3500 V

1500 uH

BULK

200 V-us

L18.5XB17.5XH11.1 (mm)

70 Cel

GENERAL PURPOSE

-25 Cel

11.5 mm

17.5 mm

380

e3

18.5 mm

1:1:1

ISNF-0249-D101

Schurter Ag

PULSE TRANSFORMER

SURFACE MOUNT

TIN

1

1000 ns

3500 V

1400 uH

BULK

250 V-us

L18.2XB17.8XH13.5 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13.5 mm

17.8 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

18.2 mm

1:1:1

ISRA-0235-D103

Schurter Ag

PULSE TRANSFORMER

SURFACE MOUNT

TIN

1

50 ns

3200 V

2800 uH

BULK

200 V-us

L15.2XB13.0XH11.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

11 mm

13 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

15.2 mm

1:1

ISRA-0239-D502

Schurter Ag

PULSE TRANSFORMER

SURFACE MOUNT

VDE

TIN

1

100 ns

3200 V

2200 uH

BULK

400 V-us

L22.7XB22.3XH14.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

14 mm

22.3 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

22.7 mm

1:1

ISRF-0235-D101

Schurter Ag

PULSE TRANSFORMER

SURFACE MOUNT

TIN

1

50 ns

3200 V

1100 uH

BULK

150 V-us

L15.2XB13.0XH11.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

11 mm

13 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

15.2 mm

1:1:1

ISRF-0239-D502

Schurter Ag

PULSE TRANSFORMER

SURFACE MOUNT

TIN

1

500 ns

3200 V

1600 uH

BULK

350 V-us

L22.7XB22.3XH14.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

14 mm

22.3 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

22.7 mm

1:1:1

ISRF-0249-D101

Schurter Ag

PULSE TRANSFORMER

SURFACE MOUNT

TIN

1

50 ns

3200 V

1200 uH

BULK

250 V-us

L18.2XB17.8XH13.5 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13.5 mm

17.8 mm

HEIGHT DIMENSION INCLUDES TERMINAL ALSO

e3

18.2 mm

1:1:1

ITNF-0239-D202

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

IEC; UL

TIN

1

1500 ns

3500 V

1600 uH

BULK

350 V-us

L22.7XB22.3XH13.6 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13.6 mm

22.3 mm

e3

22.7 mm

1:1:1

ITNF-0249-D101

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

IEC; UL

TIN

1

1000 ns

3500 V

1400 uH

BULK

250 V-us

L18.2XB17.8XH13.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13 mm

17.8 mm

e3

18.2 mm

1:1:1

ITRA-0239-D502

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

IEC; UL

TIN

1

100 ns

3200 V

2200 uH

BULK

400 V-us

L22.7XB22.3XH13.6 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13.6 mm

22.3 mm

e3

22.7 mm

1:1

ITRA-0249-D104

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

IEC; UL

TIN

1

50 ns

3200 V

3500 uH

BULK

300 V-us

L18.2XB17.8XH13.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13 mm

17.8 mm

e3

18.2 mm

1:1

ITRF-0249-D101

Schurter Ag

PULSE TRANSFORMER

THROUGH HOLE MOUNTED

VDE

TIN

1

50 ns

3200 V

1200 uH

BULK

250 V-us

L18.2XB17.8XH13.0 (mm)

100 Cel

GENERAL PURPOSE

-25 Cel

13 mm

17.8 mm

e3

18.2 mm

1:1:1

SM453229A-381-N7Y

Bourns

DATACOM TRANSFORMER

SURFACE MOUNT

AEC-Q200

TIN

1

1500 V

380 uH

TR, EMBOSSED, 13 INCH

105 Cel

10/100/1000 BASE-T

-40 Cel

2.9 mm

3.3 mm

e3

4.7 mm

1:1

Pulse & Datacom Transformers

Pulse transformers and datacom transformers are two types of transformers used in electronic circuits for signal isolation and transmission.

Pulse transformers are used to transmit short-duration electrical pulses between two circuits, while providing electrical isolation between them. They are commonly used in applications such as digital communication, pulse amplifiers, and switching power supplies. Pulse transformers are typically designed to handle high voltage and high-frequency signals, and have a low turns ratio. They are also designed to minimize signal distortion and provide high signal integrity.

Datacom transformers, also known as isolation transformers, are used to provide electrical isolation and impedance matching between two circuits in data communication applications, such as Ethernet and other networking protocols. They are used to eliminate ground loops, reduce electromagnetic interference (EMI), and provide surge protection. Datacom transformers are typically designed to handle low voltage and low-frequency signals, and have a high turns ratio. They are also designed to provide high common-mode rejection and low insertion loss.