TELECOM TRANSFORMER Telecom Transformers 24

Reset All
Part RoHS Manufacturer Transformer Type Mounting Feature Manufacturer Series Approvals (V) Terminal Finish Impedance (Primary) Impedance (Secondary) No. of Winding (Primary) Maximum Pulse Rise Time Isolation Voltage Insertion Loss Inductance (Primary) Packing Method Minimum ET Product Maximum DC Unbalance Current No. of Winding (Secondary) Sub-Category Dimensions Maximum Operating Temperature Application Minimum Operating Temperature Height Width Nominal Input Voltage (V) Load Resistance Additional Features JESD-609 Code Minimum Operating Frequency Length Turns Ratio (Np:Ns) Maximum Operating Frequency

8517

Api Technologies

TELECOM TRANSFORMER

SURFACE MOUNT

85 Cel

-40 Cel

8.64 mm

11.58 mm

TURNS RATIO: 1CT:2.3CT; 1CT:2CT

17.15 mm

PE-65415

Pulse Electronics

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

PE-65415

UL

TUBE

L12.7XB8.89XH6.35 (mm)

70 Cel

0 Cel

6.35 mm

8.89 mm

TURNS RATIO: 1CT:2CT

12.7 mm

B1056

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

B1056

TRAY

100 mA

17.65mm X 13.46mm X 12.32mm

85 Cel

-40 Cel

12.32 mm

13.46 mm

LENGTH DIMENSION INCLUDES TERMINAL ALSO; TURNS RATIO: 1CT:3CS

17.65 mm

PE-65389NL

Pulse Electronics

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

UL

1

1500 V

1500 uH

TUBE

1

Other Transformers

L12.7XB8.89XH6.35 (mm)

70 Cel

SIGNAL

0 Cel

6.35 mm

8.89 mm

.9 ohm

TURNS RATIO: 1:1/1.26

12.7 mm

1:1/1.26

PE-65415NL

Pulse Electronics

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

UL

TUBE

L12.7XB8.89XH6.35 (mm)

70 Cel

0 Cel

6.35 mm

8.89 mm

TURNS RATIO: 1CT:2CT

12.7 mm

PE-65870NL

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

UL

Matte Tin (Sn)

TUBE

L12.83XB7.11XH6.22 (mm)

70 Cel

0 Cel

6.22 mm

7.11 mm

HEIGHT DIM INCLUDES TERMINAL ALSO, TURNS RATIO: 1CT:1.15CT; 1CT:1.15CT

e3

12.83 mm

PE-68786NLT

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

TAPE & REEL

L12.83XB7.11XH6.22 (mm)

70 Cel

0 Cel

6.22 mm

7.11 mm

HEIGHT DIM INCLUDES TERMINAL ALSO, TURNS RATIO: 1CT:1.41CT; 1CT:1.41CT

12.83 mm

T6003NLT

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

600 OHMS

600 OHMS

TRAY

L13.46XB17.65XH12.32 (mm)

12.32 mm

17.65 mm

TURNS RATIO: 1:1

13.46 mm

T3001NL

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

UL

Matte Tin (Sn)

TUBE

L7.62XB7.0XH6.35 (mm)

85 Cel

-40 Cel

6.35 mm

7 mm

TURNS RATIO: 1:1, HEIGHT DIM INCLUDES TERMINAL ALSO

e3

200 KHz

7.62 mm

340000 KHz

TX1287

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

TX1287

UL

2

1500 V

1200 uH

TUBE

2

Other Transformers

12.83mm X 7.11mm X 6.22mm

85 Cel

SIGNAL

-40 Cel

6.22 mm

7.11 mm

.7 ohm

HEIGHT DIM INCLUDES TERMINAL ALSO, TURNS RATIO: 1CT:2.42CT; 1CT:2.42CT

12.83 mm

1CT:2.42CT/1CT:2.42CT

MET-31

Tamura

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

Tin (Sn)

600 OHMS CT

600 OHMS CT

85 Cel

-20 Cel

11.8 mm

7.87 mm

TURNS RATIO : 1:1

e3

.3 KHz

10.4 mm

100 KHz

MET-42

Tamura

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

150 OHMS

85 Cel

-20 Cel

11.8 mm

7.87 mm

TURNS RATIO: 3.54:1

.3 KHz

10.4 mm

100 KHz

MET-59

Tamura

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

600 OHMS

600 OHMS CT

3 mA

L10.4XB7.87XH11.8 (mm)

11.8 mm

7.87 mm

.3 KHz

10.4 mm

100 KHz

TTC-02

Tamura

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

CSA, UL

600 OHMS

12.4 mm

16.5 mm

.3 KHz

20.3 mm

3.5 KHz

TTC-105-1

Tamura

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

CSA, UL

600 OHMS

19 mm

16 mm

TURNS RATIO: 1:1

.66 KHz

20.7 mm

3.5 KHz

TTC-5020

Tamura

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

CSA, UL

600 OHMS

13.8 mm

22.5 mm

TURNS RATIO: 1:1

.6 KHz

23.1 mm

3.5 KHz

C2202

TE Connectivity

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

C2202

BABT; CSA; IEC; UL

L13.97XB13.97XH12.7 (mm)

12.7 mm

13.97 mm

BREADTH DIMENSION INCLUDES TERMINAL ALSO; TURNS RATIO: 1:1

13.97 mm

LM-LP-1004L

Bourns

TELECOM TRANSFORMER

THROUGH HOLE MOUNTED

UL

600 OHMS

600 OHMS

L17.7XB17.7XH12.6 (mm)

60 Cel

-10 Cel

12.6 mm

17.7 mm

TURNS RATIO: 1:1

.2 KHz

17.7 mm

3.5 KHz

PE-65812NL

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

UL

Tin/Silver (Sn/Ag) - hot dipped

1

25 ns

2000 V

3 dB

2500 uH

TUBE

20 V-us

1

Other Transformers

L12.06XB10.16XH8.64 (mm)

70 Cel

SIGNAL

0 Cel

8.64 mm

10.16 mm

TURNS RATIO: 1:1, HEIGHT INCLUDES TERMINAL ALSO

100 KHz

12.06 mm

1:1

55000 KHz

T1137NLT

Pulse Electronics

TELECOM TRANSFORMER

SURFACE MOUNT

T1137

2

1500 V

1200 uH

TAPE & REEL

2

Other Transformers

L12.83XB7.11XH6.22 (mm)

70 Cel

SIGNAL

0 Cel

6.22 mm

7.11 mm

.0012 ohm

HEIGHT DIM INCLUDES TERMINAL ALSO, TURNS RATIO: 1CT:2.42CT; 1CT:2.42CT

12.83 mm

1CT:2.42CT/1CT:2.42CT

TTC-5024

Tamura

TELECOM TRANSFORMER

SURFACE MOUNT

EN, UL

600 OHMS

85 Cel

-20 Cel

5.08 mm

8.5 mm

TURNS RATIO: 1:1

.2 KHz

16.3 mm

4 KHz

TTC-5027

Tamura

TELECOM TRANSFORMER

SURFACE MOUNT

EN, UL

30000 OHMS

30000 OHMS

85 Cel

-20 Cel

7.6 mm

9.6 mm

TURNS RATIO: 1:1

12.5 mm

TTC-5035

Tamura

TELECOM TRANSFORMER

SURFACE MOUNT

EN, UL

600 OHMS

346 OHMS

85 Cel

-20 Cel

7.6 mm

9.6 mm

TURNS RATIO: 1:1

.2 KHz

12.5 mm

4 KHz

TTC-5036

Tamura

TELECOM TRANSFORMER

SURFACE MOUNT

EN, UL

600 OHMS

287 OHMS

85 Cel

-20 Cel

7.6 mm

9.6 mm

TURNS RATIO: 1:1

.2 KHz

12.5 mm

4 KHz

Telecom Transformers

Telecom transformers are a type of transformer used in telecommunications equipment to isolate and match impedance between different parts of a circuit. They are commonly used in applications such as modems, routers, switches, and telephone systems.

The primary function of a telecom transformer is to isolate the AC signal from the equipment to prevent noise and interference from other components in the circuit. Telecom transformers are also used to match impedance between the input and output stages of the circuit to ensure maximum power transfer and signal integrity.

Telecom transformers are typically designed to operate at low frequencies, ranging from a few Hz to several kHz, depending on the specific application. They are designed to handle low power levels and have low losses. The design of a telecom transformer is usually optimized for a specific frequency range and bandwidth.

Telecom transformers are typically constructed with a magnetic core made of ferrite or powdered iron, and one or more coils wound around the core. The coils are usually made of copper wire with a thin insulating layer. The number of turns and the size of the wire are determined by the required impedance transformation and the frequency range of the circuit.