DIN Rail Mount Circuit Breaker 165

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3RV2011-1FA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

3RV2721-4BD10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

Rotary Handle

5.669 in (144 mm)

1.772 in (45 mm)

IP00; IP20

5.669 x 1.772 x 3.819 in (144 x 45 x 97 mm)

Trip

3.819 in (97 mm)

3

60 °C (140 °F)

410202

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Manual On/Off

3.11 in (79 mm)

IEC

2

70 °C (158 °F)

410215

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

25 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

410218

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

50 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

3.154 in (80.1 mm)

Manual On/Off

3.11 in (79 mm)

IEC

3

70 °C (158 °F)

410229

Legrand

Thermal Magnetic Circuit Breaker

DIN Rail Mount

400 V

32 A

Snap On

-25 °C (-13 °F)

50 kA

Toggle Handle

Bulk

4.106 in (104.3 mm)

4.205 in (106.8 mm)

Manual On/Off

3.11 in (79 mm)

IEC

4

70 °C (158 °F)

5SY4110-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4110-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SJ4106-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4106-7HG41

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

4.283 in (108.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

4.283 x 0.693 x 2.748 in (108.8 x 17.6 x 69.8 mm)

Trip

2.748 in (69.8 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

5SY4106-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

6 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4106-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CE; EAC; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SJ4110-7HG40

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Snap On

-25 °C (-13 °F)

14 kA

5SJ4110-7HG40

ENVIRONMENTAL CHARACTERISTICS: IP20; IP40; SEALED

3.543 in (90 mm)

0.709 in (18 mm)

Environment/Moisture Resistant

3.543 x 0.709 x 2.756 in (90 x 18 x 70 mm)

Trip

2.756 in (70 mm)

CCC; CE; EAC; UL; VDE

1

55 °C (131 °F)

3RV2021-4BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Screw And Snap On

-20 °C (-4 °F)

2 kA

3RV2021-4BA10

3.819 in (97 mm)

1.772 in (45 mm)

Moisture Resistant; IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

3.815 in (96.9 mm)

CCC; CSA; EAC; KTL; UL

3

60 °C (140 °F)

3RV2011-1HA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

450 V

8 A

Screw And Snap On

-20 °C (-4 °F)

4 kA

Rotary Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.78 in (97 x 45 x 96 mm)

Trip

3.78 in (96 mm)

3

60 °C (140 °F)

2907640

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

60 V

20 A

Snap On

-35 °C (-31 °F)

10 kA

Bulk

4.567 in (116 mm)

0.693 in (17.6 mm)

2.665 in (67.7 mm)

CUL; IEC-60947-2; UL

1

70 °C (158 °F)

5SY4104-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

4 A

Snap On

-25 °C (-13 °F)

5 kA

5SY4104-7

Environmental Characteristics: IP20; Sealed

3.535 in (89.8 mm)

0.693 in (17.6 mm)

Environment/Moisture Resistant

3.535 x 0.693 x 2.764 in (89.8 x 17.6 x 70.2 mm)

Trip

2.764 in (70.2 mm)

CCC; CE; EAC; GOST; IMQ; KTL; UL; VDE

1

55 °C (131 °F)

5SY4210-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

10 A

Screw And Snap On

-25 °C (-13 °F)

5 kA

Environmental Characteristics: Sealed

3.535 in (89.8 mm)

1.386 in (35.2 mm)

Environment/Moisture Resistant; IP20

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CE; CCC; IMQ; RCM; UL; VDE

2

55 °C (131 °F)

60139

Schneider Electric Sa

Thermal Magnetic Circuit Breaker

DIN Rail Mount

440 V

125 V

4 A

Snap On

-30 °C (-22 °F)

6 kA

Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40

Toggle

2.874 in (73 mm)

1.417 in (36 mm)

Environment/Moisture Resistant; IP20

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Trip

4.213 in (107 mm)

CCC; CSA; GB; IEC; UL

2

70 °C (158 °F)

5SY4213-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

13 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

5SY4208-8

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

400 V

8 A

Snap On

-25 °C (-13 °F)

5 kA

Interrupting current max(DC): 10000 A

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2.992 in (76 mm)

CCC; CE; GOST; IMQ; UL; VDE

2

55 °C (131 °F)

102082

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

4 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

5SY4120-7

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

20 A

Snap On

-25 °C (-13 °F)

5 kA

3.535 in (89.8 mm)

0.693 in (17.6 mm)

IP20; Sealed

3.535 x 0.693 x 3.008 in (89.8 x 17.6 x 76.4 mm)

Trip

3.008 in (76.4 mm)

CCC; CE; IMQ; RCM; UL; VDE

1

55 °C (131 °F)

102083

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

5 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

1

75 °C (167 °F)

102164

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

6 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

102167

Eaton Corporation

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

48 V

10 A

Snap On

-25 °C (-13 °F)

15 kA

Rated breaking capacity at 400 VAC

IP20; IP40

Trip

CE; CSA; EN; IEC; UL

2

75 °C (167 °F)

5SJ4218-7HG41

Siemens

Thermal Circuit Breaker

DIN Rail Mount

400 V

15 A

Snap On

-25 °C (-13 °F)

14 kA

Environmental Characteristics: Sealed

4.283 in (108.8 mm)

1.386 in (35.2 mm)

Environment Resistant; IP20; IP40

4.283 x 1.386 x 3.031 in (108.8 x 35.2 x 77 mm)

Trip

3.031 in (77 mm)

CCC; CE; UL; VDE

2

55 °C (131 °F)

3RV1011-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP00; IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1FA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1EA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

4 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1FA25

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

5 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1DA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1HA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

8 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV1011-0GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

630 mA

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Rocker

3.543 in (90 mm)

1.772 in (45 mm)

IP20

3.543 x 1.772 x 2.953 in (90 x 45 x 75 mm)

Trip

2.953 in (75 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; UL; VDE

3

60 °C (140 °F)

3RV2011-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1DA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1DA20

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

3.2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

4.173 in (106 mm)

1.772 in (45 mm)

IP20

4.173 x 1.772 x 3.815 in (106 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-0JA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1 A

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2011-1AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

1.6 A

Snap On

-20 °C (-4 °F)

100 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

3RV2021-1GA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

6.3 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-4BA15

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

20 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-4AA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

16 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-1BA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2021-4CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

22 A

Snap On

-20 °C (-4 °F)

2 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

3RV2011-1CA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

2.5 A

Snap On

-20 °C (-4 °F)

10 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

1020036

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

63 A

Snap On

-35 °C (-31 °F)

7.5 kA

Bulk

3.205 in (81.4 mm)

1.39 in (35.3 mm)

IP20

2.587 in (65.7 mm)

CUL; IEC-60947-2; UL

3

70 °C (158 °F)

3RV2011-1JA10

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

690 V

10 A

Snap On

-20 °C (-4 °F)

4 kA

Interrupting current max at 450 VDC: 10000 A

Handle

3.819 in (97 mm)

1.772 in (45 mm)

IP20

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Trip

3.815 in (96.9 mm)

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

3

60 °C (140 °F)

Instantaneous

5SY4103-8

Siemens

Thermal Magnetic Circuit Breaker

DIN Rail Mount

277 V

3 A

Snap On

-25 °C (-13 °F)

5 kA

Handle

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Trip

2.992 in (76 mm)

CE; CSA; EN; UL

1

45 °C (113 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.