240 V Circuit Breaker 57

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

1410-L210-L2F1-S02-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

2 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

1410-L210-L2F1-S02-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

5 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A

Reset Slide

1.102 in (28 mm)

0.354 in (9 mm)

Corrosion Resistant

e4

1.102 x 0.354 x 0.425 in (28 x 9 x 10.8 mm)

0.425 in (10.8 mm)

CSA; UL; VDE

1

70 °C (158 °F)

2C6UL

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

6 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.146 in (105.3 mm)

1.378 in (35 mm)

Trip

2.693 in (68.4 mm)

CE, CUL, UL

2

55 °C (131 °F)

3CU25L

Altech

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

25 A

Snap On

-25 °C (-13 °F)

10 kA

Toggle Handle

Bulk

4.291 in (109 mm)

2.067 in (52.5 mm)

IP20

Trip

2.362 in (60 mm)

CE, CUL, UL

3

60 °C (140 °F)

W23-X1A1G-50

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W23-X1A1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Push-Pull

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-15

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-25

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

25 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

W31-X2M1G-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Screw

1 kA

6 s

Toggle

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Corrosion/Environment/Moisture Resistant

Series Trip

1.6 in (40.64 mm)

CSA; UL

1

1410-L110-L1F1-S01-1A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Through Hole Mount

240 V

28 V

1 A

Printed Circuit Board

-20 °C (-4 °F)

Silver

2 kA

Rated breaking capacity at 50 VDC: 200 A, Environmental Characteristics: IP40; IP00

Reset Button

0.984 in (25 mm)

0.504 in (12.8 mm)

Corrosion Resistant; Moisture Resistant

e4

0.984 x 0.504 x 0.591 in (25 x 12.8 x 15 mm)

0.591 in (15 mm)

CSA; UL; VDE

1

70 °C (158 °F)

CA1-B2-12-610-121-MG

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

80 V

10 A

Stud

-40 °C (-40 °F)

10 kA

Handle

1.85 in (47 mm)

0.75 in (19.05 mm)

Series Trip

2.5 in (63.5 mm)

UL

1

85 °C (185 °F)

1658-G21-01-P13-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

15 A

Quick Connect

-20 °C (-4 °F)

1 kA

Push To Reset

Bulk

1.26 in (32 mm)

0.535 in (13.6 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.063 in (27 mm)

CSA; CUL; UL

1

60 °C (140 °F)

AP1-1-72-103

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 V

10 A

Solder Hook

-40 °C (-40 °F)

1 kA

Toggle

1.562 in (39.67 mm)

0.656 in (16.66 mm)

Corrosion Resistant; Sealed

Trip Free

1.605 in (40.77 mm)

1

100 °C (212 °F)

MS2-B-20-615-1-1CB-A-0DC

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Quick Connect

-40 °C (-40 °F)

2 kA

Sealed Toggle

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Moisture Resistant; IP68;

Series Trip

2.158 in (54.81 mm)

CUL; UL

2

85 °C (185 °F)

MS2-M-24-620-2-1CA-A-0CA

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

20 A

Screw

-40 °C (-40 °F)

2 kA

Sealed Toggle

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Moisture Resistant; IP68;

Series Trip

2.158 in (54.81 mm)

2

85 °C (185 °F)

GA1-B0-20-615-11-DC

Carling Technologies

Magnetic Circuit Breaker

DIN Rail Mount

240 V

15 A

Snap On

-40 °C (-40 °F)

3 kA

Handle

3.625 in (92.08 mm)

0.688 in (17.48 mm)

Corrosion/Moisture Resistant

Series Trip

2.62 in (66.55 mm)

CSA, UL

1

85 °C (185 °F)

TA45-ABFGP140C0-AZM14

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

14 A

Quick Connect

-10 °C (14 °F)

1 kA

Rocker

1.89 in (48 mm)

0.984 in (25 mm)

IP00; IP40; IP54; IP65

Trip

1.339 in (34 mm)

CSA; SEMKO; SEV; UL; VDE

2

55 °C (131 °F)

TA45-ABFXF110C0-AZM13

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

11 A

Quick Connect

-10 °C (14 °F)

1 kA

Rocker

1.89 in (48 mm)

0.984 in (25 mm)

IP00; IP40; IP54; IP65

Manual On/Off

1.339 in (34 mm)

CSA; SEMKO; SEV; UL; VDE

2

55 °C (131 °F)

3120-N311-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W02D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N321-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-3A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

3 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W02D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N323-P7T1-W01D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

4130-G211-K4M1-50A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

50 A

Screw

-30 °C (-22 °F)

800 A

Push To Reset

1.26 in (32 mm)

0.709 in (18 mm)

Corrosion Resistant; IP00; IP40

1.26 x 0.709 x 1.969 in (32 x 18 x 50 mm)

Tease-Free And Trip-Free

1.969 in (50 mm)

CBE; CSA; EN; IEC; UL; VDE

1

60 °C (140 °F)

Medium

209-1-1-62-4-9-10

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

10 A

Stud

5 kA

Toggle

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL

1

209-1-1-62-4-9-15-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Stud

5 kA

Toggle

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Moisture Resistant

Trip Free

3.55 in (90.17 mm)

CSA; CUL; UL; VDE

1

PCB-B1-22-650-1AD-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

50 A

Stud

-35 °C (-31 °F)

5 kA

Rocker

3.8 in (96.52 mm)

3.015 in (76.58 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

PCG-BA-24-616-1DA-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

16 A

Stud

-35 °C (-31 °F)

3 kA

Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Series Trip

2.975 in (75.57 mm)

CSA; UL

2

66 °C (150.8 °F)

PCG-BA-24-625-1GA-E11

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

25 A

Stud

-35 °C (-31 °F)

5 kA

Toggle Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

PCG-BA-24-630-11A-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

30 A

Stud

-35 °C (-31 °F)

5 kA

Toggle Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

PCG-BA-24-630-1AA-E12

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

30 A

Stud

-35 °C (-31 °F)

3 kA

Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Series Trip

2.975 in (75.57 mm)

CSA; UL

2

66 °C (150.8 °F)

PCG-BA-24-650-1GA-E11

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

50 A

Stud

-35 °C (-31 °F)

5 kA

Toggle Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Moisture Resistant

Series Trip

2.975 in (75.57 mm)

UL

2

66 °C (150.8 °F)

PCG-BA-24-650-1GB-E11

Carling Technologies

Equipment Leakage Circuit Breaker

Panel Mount

240 V

50 A

Stud

-35 °C (-31 °F)

3 kA

Handle

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Series Trip

2.975 in (75.57 mm)

CSA; UL

2

66 °C (150.8 °F)

3-101-228

Schurter Ag

Thermal Circuit Breaker

Through Hole Mount

240 V

48 V

4 A

Solder

-5 °C (23 °F)

2 kA

Reset Type

Bulk

0.748 in (19 mm)

0.575 in (14.6 mm)

IP40

Trip Free

1.421 in (36.1 mm)

CCC; CSA; GB; IEC; UL; VDE

1

60 °C (140 °F)

EA3-B0-62-650-12B-CC

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

50 A

Stud

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL

3

85 °C (185 °F)

EA3-B0-64-475-22A-DF

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

7.5 A

Stud

-40 °C (-40 °F)

5 kA

Handle

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Corrosion/Moisture Resistant

Series Trip

2.61 in (66.3 mm)

CSA; UL; VDE

3

85 °C (185 °F)

1658-G21-02-P10-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

10 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

1658-G21-02-P10-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Inline/Holder

240 V

28 V

20 A

Tab/Blade

-20 °C (-4 °F)

200 A

Manual Reset

1.26 in (32 mm)

0.551 in (14 mm)

Trip Free

1.563 in (39.7 mm)

CSA; CUL; UL; VDE

1

60 °C (140 °F)

GFL2D200302

Altech

Magnetic Circuit Breaker

DIN Rail Mount

240 V

20 A

Snap On

10 kA

Toggle

4.134 in (105 mm)

1.378 in (35 mm)

Trip

2.362 in (60 mm)

CUL; UL

1

3120-N321-P7T1-W19DG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.