240 V Circuit Breaker 57

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

3120-N321-P7T1-W19DG4-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-8A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

8 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-16A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

16 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-3A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

3 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

1010289

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

40 A

Screw

-35 °C (-31 °F)

10 kA

Handle

Bulk

4.567 in (116 mm)

2.083 in (52.9 mm)

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

3

70 °C (158 °F)

1010284

Phoenix Contact

Thermal Magnetic Circuit Breaker

DIN Rail Mount

240 V

50 A

Screw

-35 °C (-31 °F)

10 kA

Handle

Bulk

4.567 in (116 mm)

2.083 in (52.9 mm)

Trip

2.587 in (65.7 mm)

CUL; TUV; UL

3

70 °C (158 °F)

3131-AF1PT-000000-000-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

2 A

Quick Connect

-20 °C (-4 °F)

20 A

Rocker

2.008 in (51 mm)

0.945 in (24 mm)

Corrosion Resistant; IP00; IP66

Manual On/Off

1.142 in (29 mm)

UL; VDE

1

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.