Quick Connect Circuit Breaker 115

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

AA2-B0-26-410-1B1-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

1 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Handle

2 in (50.8 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AC2-B2-26-610-144-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

2

85 °C (185 °F)

AD1-B2-26-610-143-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL

1

85 °C (185 °F)

AJ1-B0-32-410-1C3-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

AK1-B0-32-410-1C3-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Rocker

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

1620-2-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

10 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

15 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

20 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-25A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

25 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

30 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-2-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Modified Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP50

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

10 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

15 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

20 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-30A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

30 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1620-3-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Reset Button

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

0.984 in (25 mm)

1

85 °C (185 °F)

1658-G21-01-P13-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

15 A

Quick Connect

-20 °C (-4 °F)

1 kA

Push To Reset

Bulk

1.26 in (32 mm)

0.535 in (13.6 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.063 in (27 mm)

CSA; CUL; UL

1

60 °C (140 °F)

AN1-B0-20-615-113-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

15 A

Quick Connect

-40 °C (-40 °F)

1 kA

Standards: MIL-PRF-55629, MIL-STD-202

Push To Reset

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Corrosion/Moisture Resistant

Series Trip

1.64 in (41.66 mm)

CSA; UL; VDE

1

85 °C (185 °F)

MS2-B-20-615-1-1CB-A-0DC

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

240 V

15 A

Quick Connect

-40 °C (-40 °F)

2 kA

Sealed Toggle

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Moisture Resistant; IP68;

Series Trip

2.158 in (54.81 mm)

CUL; UL

2

85 °C (185 °F)

TA45-ABFGP140C0-AZM14

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

14 A

Quick Connect

-10 °C (14 °F)

1 kA

Rocker

1.89 in (48 mm)

0.984 in (25 mm)

IP00; IP40; IP54; IP65

Trip

1.339 in (34 mm)

CSA; SEMKO; SEV; UL; VDE

2

55 °C (131 °F)

TA45-ABFXF110C0-AZM13

Schurter Ag

Thermal Circuit Breaker

Panel Mount

240 V

60 V

11 A

Quick Connect

-10 °C (14 °F)

1 kA

Rocker

1.89 in (48 mm)

0.984 in (25 mm)

IP00; IP40; IP54; IP65

Manual On/Off

1.339 in (34 mm)

CSA; SEMKO; SEV; UL; VDE

2

55 °C (131 °F)

3120-N311-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N311-P7T1-W02D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

1

60 °C (140 °F)

3120-N321-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-3A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

3 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W02D-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

3120-N323-P7T1-W01D-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

2.22 in (56.4 mm)

0.984 in (25 mm)

Corrosion Resistant; IP00; IP40

Trip Free

1.299 in (33 mm)

CCC; CSA; KC; UL; VDE

2

60 °C (140 °F)

219-3-1-66-8-2-30-V

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

480 V

30 A

Quick Connect

10 kA

Toggle Handle

5.8 in (147.32 mm)

3.108 in (78.94 mm)

Moisture Resistant

Trip Free

2.61 in (66.29 mm)

CSA; CUL; UL; VDE

3

279-2-1-52-9-2-90

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

160 V

90 A

Quick Connect

5 kA

Toggle Handle

5.8 in (147.32 mm)

2.072 in (52.63 mm)

Moisture Resistant

Trip Free

2.61 in (66.29 mm)

CSA; CUL; UL

2

CLB-103-27E3A-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E6A-B-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E6N-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

CLB-103-27E7N-W-A

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

10 A

Quick Connect

-10 °C (14 °F)

300 A

Rated breaking capacity at 32 VDC: 2500 A

Push To Reset

1.378 in (35 mm)

0.571 in (14.5 mm)

Fire Resistant

Series Trip

1.693 in (43 mm)

CE; TUV; UL

1

60 °C (140 °F)

BB3-B0-26-620-121-D

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

277 V

20 A

Quick Connect

-40 °C (-40 °F)

1.5 kA

Toggle Handle

2 in (50.8 mm)

2.265 in (57.53 mm)

Corrosion/Moisture Resistant

Series Trip

1.73 in (43.94 mm)

CSA; UL; VDE

3

85 °C (185 °F)

4-1393249-1

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

15 A

Quick Connect

1 kA

6 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.494 in (37.96 mm)

1

W58-XC4C12A-10

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

10 A

Quick Connect

1 kA

6 s

Push To Reset

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Series Trip

1.375 in (34.93 mm)

1

W67-X2Q52-25

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

65 V

25 A

Quick Connect

2.2 s

Toggle

Series Trip

1

W68-X2Q10-10

TE Connectivity

Magnetic Circuit Breaker

Panel Mount

277 V

10 A

Quick Connect

-40 °C (-40 °F)

5 kA

30 ms

Toggle

2 in (50.8 mm)

1.5 in (38.1 mm)

Series Trip

1.64 in (41.66 mm)

2

85 °C (185 °F)

W33-S4B1Q-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

1 kA

3 s

Rocker

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Series Trip

1.724 in (43.79 mm)

2

W57-XB2A99C10-5

TE Connectivity

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

0 °C (32 °F)

1 kA

4 s

Push To Reset

1.15 in (29.2 mm)

0.575 in (14.6 mm)

Series Trip

0.89 in (22.6 mm)

1

60 °C (140 °F)

CTB-B-B-15

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

50 V

15 A

Quick Connect

1 kA

Rocker

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Series Trip

1.535 in (38.99 mm)

CE; CUL; UL; VDE

1

CMB-053-27G3N-W-A/05

Carling Technologies

Thermal Circuit Breaker

Panel Mount

250 V

32 V

5 A

Quick Connect

-10 °C (14 °F)

1 kA

Push To Reset

1.154 in (29.3 mm)

0.551 in (14 mm)

Series Trip

1.78 in (45.2 mm)

CSA; CE; CUL; TUV; UL

1

60 °C (140 °F)

MF1-B-32-410-1-CE3-B-C

Carling Technologies

Magnetic Circuit Breaker

Panel Mount

125 V

80 V

1 A

Quick Connect

-40 °C (-40 °F)

360 A

Rated breaking capacity at 80 VDC: 600 A

Rocker

1.56 in (39.62 mm)

0.77 in (19.56 mm)

Corrosion/Moisture Resistant

Series Trip

1.53 in (38.86 mm)

CSA, UL

1

85 °C (185 °F)

1620-3H-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

12 V

5 A

Quick Connect

-40 °C (-40 °F)

150 A

Manual Reset

0.524 in (13.3 mm)

0.276 in (7 mm)

Corrosion Resistant; IP00; IP40

Trip

1.189 in (30.2 mm)

1

85 °C (185 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.