Quick Connect Circuit Breaker 115

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Actuator Type Packing Method Body Length/Diameter Body Width Environmental Characteristics JESD-609 Code Dimensions Circuit Function Body Height Reference Standard No. of Poles Maximum Operating Temperature Blow Characteristic

2-5700-IG1-P10-DD-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

20 A

Quick Connect

-20 °C (-4 °F)

2 kA

Rated breaking capacity at 50 VDC: 2500 A

Push To Reset

1.142 in (29 mm)

0.571 in (14.5 mm)

Corrosion/Moisture Resistant; IP00; IP40

Trip Free

1.831 in (46.5 mm)

CQC; CSA; UL; VDE

1

60 °C (140 °F)

1140-G151-P7M1-16A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

16 A

Quick Connect

-20 °C (-4 °F)

2 kA

Push To Reset

0.748 in (19 mm)

0.433 in (11 mm)

Corrosion Resistant; IP00; IP40

Trip Free

2.374 in (60.3 mm)

CSA; UL; VDE

2

60 °C (140 °F)

R58-1A

Nte Electronics

Thermal Circuit Breaker

Panel Mount

250 V

50 V

1 A

Quick Connect

1 kA

Rated breaking capacity at 50 VDC: 2000 A

Push Button

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Trip

1.375 in (34.93 mm)

CSA; UL

1

203-22-1-66-103-4-1-1

Sensata Technologies

Magnetic Circuit Breaker

Panel Mount

250 V

Quick Connect

-40 °C (-40 °F)

2 kA

Rocker

2 in (50.8 mm)

1.54 in (39.12 mm)

Series Trip

1.77 in (44.96 mm)

CSA; UL

2

85 °C (185 °F)

ESX10-103-DC24V-3A-E

E-t-a Elektrotechnische Apparate

Equipment Leakage Circuit Breaker

Panel Mount

24 V

3 A

Quick Connect

0 °C (32 °F)

Manual On/Off

2.362 in (60 mm)

0.484 in (12.3 mm)

Moisture Resistant; IP00; IP30

Trip

2.756 in (70 mm)

CSA; CUL; DNVGL; UL

1

50 °C (122 °F)

3120-N321-P7T1-W19DG4-10A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

10 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-15A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

15 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

5 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-8A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

8 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-6A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

6 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-16A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

16 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

3120-N321-P7T1-W19DG4-3A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

50 V

3 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion/Moisture Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UL; VDE

2

60 °C (140 °F)

1324402

Phoenix Contact

Thermal Circuit Breaker

Panel Mount

250 V

72 V

16 A

Quick Connect

-20 °C (-4 °F)

200 A

Push Button

Bulk

1.752 in (44.5 mm)

0.374 in (9.5 mm)

IP00; IP40

Trip

0.961 in (24.4 mm)

CCC; CSA; CUL; UL; VDE

60 °C (140 °F)

1110-F112-P1M1-5A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

250 V

50 V

5 A

Quick Connect

-20 °C (-4 °F)

40 A

Rated breaking capacity at 50 VDC: 50 A

Push Button

0.748 in (19 mm)

0.748 in (19 mm)

Corrosion Resistant; IP00; IP40; IP64

Tease-Free And Trip-Free

2.008 in (51 mm)

CSA; CUL; EN; UL; VDE

1

60 °C (140 °F)

3131-AF1PT-000000-000-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

240 V

28 V

2 A

Quick Connect

-20 °C (-4 °F)

20 A

Rocker

2.008 in (51 mm)

0.945 in (24 mm)

Corrosion Resistant; IP00; IP66

Manual On/Off

1.142 in (29 mm)

UL; VDE

1

60 °C (140 °F)

3120-N324-P7T1-W19DG3-20A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

115 V

20 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

3120-N32A-H7T1-W12LY4-2A

E-t-a Elektrotechnische Apparate

Thermal Circuit Breaker

Panel Mount

230 V

2 A

Quick Connect

-30 °C (-22 °F)

5 kA

Rated breaking capacity at 50 VDC: 1000 A

Rocker

Corrosion Resistant; IP00; IP40

Manual On/Off

CCC; CE; CSA; CQC; KTL; UKCA; UL; VDE

2

60 °C (140 °F)

Circuit Breaker

A circuit breaker is an automatic electrical switch that is designed to protect an electrical circuit from damage caused by overcurrent or short circuits. Circuit breakers are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

Circuit breakers work by monitoring the amount of current flowing through an electrical circuit. If the current exceeds a preset level, the circuit breaker will trip, or open the circuit, to prevent damage to the electrical system. When the circuit breaker trips, it interrupts the flow of current, which stops the electrical current from flowing and prevents further damage.

Circuit breakers are available in a variety of types and sizes, and they can be classified based on their voltage rating, current rating, and interrupting capacity. Some common types of circuit breakers include thermal circuit breakers, magnetic circuit breakers, and hybrid circuit breakers.

In addition to protecting electrical systems from overcurrent and short circuits, circuit breakers also help improve the reliability and efficiency of electrical systems. They can also be used to switch electrical circuits on and off, which can be helpful in certain applications.