Tab/Blade Fuses 810

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

LA70QS100-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

100 A

Tab/Blade

3.6 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS125-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

125 A

Tab/Blade

6.9 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS125-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

125 A

Tab/Blade

6.9 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS150-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

150 A

Tab/Blade

11 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS150-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

150 A

Tab/Blade

11 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS175-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

175 A

Tab/Blade

14 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS175-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

175 A

Tab/Blade

14 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS200-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

200 A

Tab/Blade

19 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS200-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

200 A

Tab/Blade

19 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.22 in (31 mm)

1.22 x 2.874 in (31 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS250-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

250 A

Tab/Blade

42 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 2.843 in (38.1 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS300-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

300 A

Tab/Blade

55 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 2.843 in (38.1 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS35-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

35 A

Tab/Blade

470 mJ

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS350-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

350 A

Tab/Blade

72 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 2.843 in (38.1 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS40-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

40 A

Tab/Blade

580 mJ

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS400-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

400 A

Tab/Blade

99 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1.5 in (38.1 mm)

1.5 x 2.843 in (38.1 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS450-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

450 A

Tab/Blade

125 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS450-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

450 A

Tab/Blade

125 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS50-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

50 A

Tab/Blade

880 mJ

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS500-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

500 A

Tab/Blade

160 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS500-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

500 A

Tab/Blade

150 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS60-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

60 A

Tab/Blade

1.2 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS600-4K

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

222 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS600-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

600 A

Tab/Blade

222 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2 in (50.8 mm)

2 x 2.843 in (50.8 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS70-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

70 A

Tab/Blade

1.8 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS700-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

700 A

Tab/Blade

332 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2.5 in (63.5 mm)

2.5 x 2.843 in (63.5 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS80-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

80 A

Tab/Blade

2.3 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

LA70QS800-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

800 A

Tab/Blade

433 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

2.5 in (63.5 mm)

2.5 x 2.843 in (63.5 x 72.2 mm)

2.843 in (72.2 mm)

CSA; UL

Fast

LA70QS90-4

Littelfuse

Electric Fuse

Inline/Holder

700 V

700 V

90 A

Tab/Blade

3 J

200 kA

Rated Breaking Capacity at 700 VDC: 100000 A

1 in (25.4 mm)

1 x 2.874 in (25.4 x 73 mm)

2.874 in (73 mm)

CSA; UL

Fast

JLLN110

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

110 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

1.063 x 0.843 in (27 x 21.4 mm)

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

JLLN150

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

150 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

1.063 x 0.843 in (27 x 21.4 mm)

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

JLLN175

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

175 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

1.063 x 0.843 in (27 x 21.4 mm)

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

JLLN200

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

200 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.063 in (27 mm)

1.063 x 0.843 in (27 x 21.4 mm)

2.437 in (61.9 mm)

CE; CSA; CUL; UL

Fast

JLLN250

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

250 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 0.827 in (33.3 x 21 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

JLLN300

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

300 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 0.827 in (33.3 x 21 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

JLLN350

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

350 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 0.827 in (33.3 x 21 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

JLLN400

Littelfuse

Electric Fuse

Inline/Holder

300 V

125 V

400 A

Tab/Blade

200 kA

Rated Breaking Capacity at 125 VDC: 20000 A

1.311 in (33.3 mm)

1.311 x 0.827 in (33.3 x 21 mm)

2.752 in (69.9 mm)

CE; CSA; CUL; UL

Fast

LA100URD73LI1000

Littelfuse

Electric Fuse

Inline/Holder

1.1 KV

1 kA

Tab/Blade

370 J

100 kA

2.933 in (74.5 mm)

2.933 in (74.5 mm)

2.933 x 2.933 x 2.854 in (74.5 x 74.5 x 72.5 mm)

2.854 in (72.5 mm)

UL

Very Fast

997005

Littelfuse

Electric Fuse

Inline/Holder

58 V

5 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

997010

Littelfuse

Electric Fuse

Inline/Holder

58 V

10 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

997015

Littelfuse

Electric Fuse

Inline/Holder

58 V

15 A

Tab/Blade

-40 °C (-40 °F)

1 kA

Rated Breaking Capacity at 58 VDC: 1000 A

0.43 in (10.92 mm)

0.15 in (3.81 mm)

0.43 x 0.15 x 0.344 in (10.92 x 3.81 x 8.75 mm)

0.344 in (8.75 mm)

125 °C (257 °F)

Fast

498150

Littelfuse

Electric Fuse

Inline/Holder

32 V

150 A

Tab/Blade

-40 °C (-40 °F)

1 kA

0.63 in (16 mm)

0.472 in (12 mm)

0.63 x 0.472 x 0.315 in (16 x 12 x 8 mm)

0.315 in (8 mm)

UL

125 °C (257 °F)

NH00CG80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CG16

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

16 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CG100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CG20

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

20 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CG10

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

10 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00CG32

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

32 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00G160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.126 in (56.4 x 30 x 54 mm)

2.126 in (54 mm)

VDE

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.