Tab/Blade Fuses 810

Reset All
Part RoHS Manufacturer Circuit Protection Type Mounting Feature Rated AC Voltage Rated DC Voltage Rated Current Terminal Shape Nominal Joule Integral Minimum Operating Temperature Terminal Finish Rated Breaking Capacity Manufacturer Series Trip Time/Delay Additional Features Pre Arcing Rating (A2/s) Packing Method Body Length/Diameter Body Width Fuse Class JESD-609 Code Rated Voltage Resistance Minimum Pre Arcing Time Fuse Size Built-in Features Dimensions Body Height Reference Standard Maximum Operating Temperature Blow Characteristic

NH00CG35

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

35 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH3G630

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

630 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

3.307 in (84 mm)

2.83 in (71.88 mm)

Indicator

3.307 x 2.83 x 2.835 in (84 x 71.88 x 72 mm)

2.835 in (72 mm)

VDE

NH00CG40

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

40 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH00M125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

NH

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH00M160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.126 in (54 mm)

1.181 in (30 mm)

Indicator

2.126 x 1.181 x 2.22 in (54 x 30 x 56.4 mm)

2.22 in (56.4 mm)

DIN 43620; IEC; VDE

NH0G125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH0G16

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

16 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH0G160

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

160 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH0G20

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

20 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH1CG100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH0G100

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

100 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH1CG125

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

125 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH1CG25

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

25 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH00CG6

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

6 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH1CG35

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

35 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH00CG63

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

63 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.02 in (51.3 mm)

0.787 in (20 mm)

Indicator

2.02 x 0.787 x 2.126 in (51.3 x 20 x 54 mm)

2.126 in (54 mm)

VDE

NH1CG40

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

40 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH0G10

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

10 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.1 in (53.34 mm)

1.181 in (30 mm)

Indicator

2.1 x 1.181 x 2.76 in (53.34 x 30 x 70.11 mm)

2.76 in (70.11 mm)

VDE

NH1CG50

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

50 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

NH1CG80

Littelfuse

Electric Fuse

Inline/Holder

500 V

440 V

80 A

Tab/Blade

120 kA

Rated Breaking Capacity at 440 VDC: 25000 A

2.22 in (56.4 mm)

1.181 in (30 mm)

Indicator

2.22 x 1.181 x 2.835 in (56.4 x 30 x 72 mm)

2.835 in (72 mm)

VDE

10-1001

Littelfuse

Electric Fuse

Inline/Holder

32 V

10 A

Tab/Blade

-40 °C (-40 °F)

1 kA

80 ms

Pre Arcing Time: Open within 80 ms at 350% Rated Current

Blister

0.76 in (19.3 mm)

0.207 in (5.25 mm)

ATO

32 V

Indicator

0.48 in (12.2 mm)

125 °C (257 °F)

LVSP0005TXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

5 A

Tab/Blade

359 J

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

LVSP0010TXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

10 A

Tab/Blade

1.3 kJ

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

LVSP0015TXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

15 A

Tab/Blade

3.267 kJ

Nickel

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

LVSP0020TXR

Littelfuse

Electric Fuse

Inline/Holder

600 V

20 A

Tab/Blade

4.94 kJ

200 kA

0.41 in (10.41 mm)

1.53 in (38.86 mm)

UL

LVSP0030T

Littelfuse

Electric Fuse

Inline/Holder

600 V

30 A

Tab/Blade

11.95 kJ

200 kA

0.816 in (20.73 mm)

2.25 in (57.15 mm)

UL

LVSP0040T

Littelfuse

Electric Fuse

Inline/Holder

600 V

40 A

Tab/Blade

20.55 kJ

200 kA

0.816 in (20.73 mm)

2.25 in (57.15 mm)

UL

LVSP0060T

Littelfuse

Electric Fuse

Inline/Holder

600 V

60 A

Tab/Blade

39.24 kJ

200 kA

0.816 in (20.73 mm)

2.25 in (57.15 mm)

UL

LVSP0080T

Littelfuse

Electric Fuse

Inline/Holder

600 V

80 A

Tab/Blade

75 kJ

200 kA

0.816 in (20.73 mm)

2.25 in (57.15 mm)

UL

LVSP0100VXL

Littelfuse

Electric Fuse

Inline/Holder

600 V

100 A

Tab/Blade

160.747 kJ

200 kA

1 in (25.4 mm)

2.62 in (66.55 mm)

UL

581100

Littelfuse

Electric Fuse

Inline/Holder

48 V

48 V

100 A

Tab/Blade

2.5 kA

581

1.535 in (39 mm)

1.195 in (30.35 mm)

1.535 x 1.195 x 0.683 in (39 x 30.35 x 17.35 mm)

0.683 in (17.35 mm)

UL

10-1004

Littelfuse

Electric Fuse

Inline/Holder

32 V

25 A

Tab/Blade

-40 °C (-40 °F)

1 kA

80 ms

Pre Arcing Time: Open within 80 ms at 350% Rated Current

Blister

0.76 in (19.3 mm)

0.207 in (5.25 mm)

Indicator

0.48 in (12.2 mm)

125 °C (257 °F)

WCF30RN

Eaton Corporation

Electric Fuse

Inline/Holder

690 V

30 A

Tab/Blade

-40 °C (-40 °F)

50 kA

1.89 in (48 mm)

0.748 in (19 mm)

240 s

0.984 in (25 mm)

CE; CUL; UL

90 °C (194 °F)

Fast

ECNR400

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

400 A

Tab/Blade

200 kA

Bulk

2.38 in (60.452 mm)

8.63 in (219.202 mm)

CE; CSA; UL

Time Delay

ECNR450

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

250 V

450 A

Tab/Blade

200 kA

Bulk

2.88 in (73.152 mm)

10.38 in (263.652 mm)

CE; CSA; UL

Time Delay

ECNR70

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

70 A

Tab/Blade

200 kA

Bulk

1.06 in (26.924 mm)

5.88 in (149.352 mm)

CE; CSA; UL

Time Delay

ECNR75

Eaton Corporation

Electric Fuse

Inline/Holder

250 V

75 A

Tab/Blade

200 kA

Bulk

1.06 in (26.924 mm)

5.88 in (149.352 mm)

CE; CSA; UL

Time Delay

PSX1XLDB0080X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

80 A

Tab/Blade

2.048 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0100X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

100 A

Tab/Blade

3.54 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0125X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

125 A

Tab/Blade

7.091 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0160X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

160 A

Tab/Blade

13.704 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0200X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

200 A

Tab/Blade

18.016 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0250X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

250 A

Tab/Blade

36.552 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0280X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

280 A

Tab/Blade

36.552 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0315X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

315 A

Tab/Blade

56.94 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0350X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

350 A

Tab/Blade

86.623 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0400X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

400 A

Tab/Blade

116.271 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

PSX1XLDB0450X

Littelfuse

Electric Fuse

Inline/Holder

1.5 KV

450 A

Tab/Blade

149.336 kJ

-55 °C (-67 °F)

250 kA

Bulk

4.988 in (126.7 mm)

2.028 in (51.5 mm)

Indicator

2.028 in (51.5 mm)

CUL; UL

125 °C (257 °F)

Fast

Fuses

A fuse is an electrical safety device that is designed to protect an electrical circuit from damage caused by overcurrent. Fuses are commonly used in residential, commercial, and industrial electrical systems, and they are an important safety device that helps prevent electrical fires, equipment damage, and personal injury.

A fuse typically consists of a metal wire or filament that is enclosed in a fuse body, which is designed to protect the wire from damage. The fuse is connected in series with the electrical circuit, and when the current flowing through the circuit exceeds a preset level, the wire in the fuse will melt or blow, which opens the circuit and prevents further damage to the electrical system.

Fuses are available in a variety of types and sizes, and they can be classified based on their current rating, voltage rating, and speed of operation. Some common types of fuses include cartridge fuses, blade fuses, and plug fuses.

In addition to protecting electrical systems from overcurrent, fuses can also be used to protect electrical equipment and machinery from damage caused by short circuits or other types of electrical faults. They are a cost-effective and reliable method of electrical protection, and they are widely used in a variety of electrical applications.